Iván Coto Hernández

Iván Coto Hernández

Auto-generated profile, based on publicly available information

Iván Coto Hernández

Massachusetts General Hospital and Harvard Medical School

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2015 in Nature Communications
Verified
Journal Article
Open access
PDF file
LLLuca Lanzano'
Luca Lanzano'
IHIván Coto Hernández
Iván Coto Hernández
MCMarco Castello
Marco Castello
EGEnrico Gratton
Enrico Gratton
ADAlberto Diaspro
Alberto Diaspro
GVGiuseppe Vicidomini
Giuseppe Vicidomini
The challenge of increasing the spatial resolution of an optical microscope beyond the diffraction limit can be reduced to a spectroscopy task by proper manipulation of the molecular states. The nanoscale spatial distribution of the molecules inside the detection volume of a scanning microscope can be encoded within the fluorescence dynamics and decoded by resolving the signal into its dynamics components. Here we present a robust and general method to decode this information using phasor analysis. As an example of the application of this method, we optically generate spatially controlled gradients in the fluorescence lifetime by stimulated emission. Spatial resolution can be increased indefinitely by increasing the number of resolved dynamics components up to a maximum determined by the amount of noise. We demonstrate that the proposed method provides nanoscale imaging of subcellular structures, opening new routes in super-resolution microscopy based on the encoding/decoding of spatial information through manipulation of molecular dynamics.

1 March 2014 in Methods
Verified
Journal Article
Closed access
GVGiuseppe Vicidomini
Giuseppe Vicidomini
IHIvan Coto Hernández
Ivan Coto Hernández
Marta D'AmoraMarta D'Amora
Marta D'Amora
Francesca Cella ZanacchiFrancesca Cella Zanacchi
Francesca Cella Zanacchi
PBPaolo Bianchini
Paolo Bianchini
ADAlberto Diaspro
Alberto Diaspro

18 March 2014 in Journal of Biophotonics
Verified
Journal Article
Open access
PDF file
IHIvàn Coto Hernàndez
Ivàn Coto Hernàndez
CPChiara Peres
Chiara Peres
Francesca Cella ZanacchiFrancesca Cella Zanacchi
Francesca Cella Zanacchi
Marta D'AmoraMarta D'Amora
Marta D'Amora
SCSotirios Christodoulou
Sotirios Christodoulou
GVGiuseppe Vicidomini
Giuseppe Vicidomini
Stimulated emission depletion (STED) microscopy is a prominent approach of super‐resolution optical microscopy, which allows cellular imaging with so far unprecedented unlimited spatial resolution. The introduction of time‐gated detection in STED microscopy significantly reduces the (instantaneous) intensity required to obtain sub‐diffraction spatial resolution. If the time‐gating is combined with a STED beam operating in continuous wave (CW), a cheap and low labour demand implementation is obtained, the so called gated CW‐STED microscope. However, time‐gating also reduces the fluorescence signal which forms the image. Thereby, background sources such as fluorescence emission excited by the STED laser (anti‐Stokes fluorescence) can reduce the effective resolution of the system. We propose a straightforward method for subtraction of anti‐Stokes background. The method hinges on the uncorrelated nature of the anti‐Stokes emission background with respect to the wanted fluorescence signal. The specific importance of the method towards the combination of two‐photon‐excitation with gated CW‐STED microscopy is demonstrated.

13 January 2016 in Scientific Reports
Verified
Journal Article
Open access
PDF file
IHIván Coto Hernández
Iván Coto Hernández
MCMarco Castello
Marco Castello
LLLuca Lanzanò
Luca Lanzanò
Marta D'AmoraMarta D'Amora
Marta D'Amora
PBPaolo Bianchini
Paolo Bianchini
GVGiuseppe Vicidomini
Giuseppe Vicidomini
We report on a novel two-photon excitation stimulated emission depletion (2PE-STED) microscope based on time-gated detection. The time-gated detection allows for the effective silencing of the fluorophores using moderate stimulated emission beam intensity. This opens the possibility of implementing an efficient 2PE-STED microscope with a stimulated emission beam running in a continuous-wave. The continuous-wave stimulated emission beam tempers the laser architecture’s complexity and cost, but the time-gated detection degrades the signal-to-noise ratio (SNR) and signal-to-background ratio (SBR) of the image. We recover the SNR and the SBR through a multi-image deconvolution algorithm. Indeed, the algorithm simultaneously reassigns early-photons (normally discarded by the time-gated detection) to their original positions and removes the background induced by the stimulated emission beam. We exemplify the benefits of this implementation by imaging sub-cellular structures. Finally, we discuss of the extension of this algorithm to future all-pulsed 2PE-STED implementationd based on time-gated detection and a nanosecond laser source.

6 July 2016 in Microscopy Research and Technique
Verified
Journal Article
Closed access
PDF file
MCMarco Castello
Marco Castello
Giorgio TortaroloGiorgio Tortarolo
Giorgio Tortarolo
IHIván Coto Hernández
Iván Coto Hernández
PBPaolo Bianchini
Paolo Bianchini
MBMauro Buttafava
Mauro Buttafava
GVGiuseppe Vicidomini
Giuseppe Vicidomini

1 May 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
MCM. Castello
M. Castello
Giorgio TortaroloGiorgio Tortarolo
Giorgio Tortarolo
IHI. Coto Hernández
I. Coto Hernández
TDT. Deguchi
T. Deguchi
ADAlberto Diaspro
Alberto Diaspro
GVGiuseppe Vicidomini
Giuseppe Vicidomini
In stimulated emission depletion (STED) microscopy, the role of the STED beam is to de-excite, via stimulated emission, the fluorophores that have been previously excited by the excitation beam. This condition, together with specific beam intensity distributions, allows obtaining true sub-diffraction spatial resolution images. However, if the STED beam has a non-negligible probability to excite the fluorophores, a strong fluorescent background signal (anti-Stokes emission) reduces the effective resolution. For STED scanning microscopy, different synchronous detection methods have been proposed to remove this anti-Stokes emission background and recover the resolution. However, every method works only for a specific STED microscopy implementation. Here we present a user-friendly synchronous detection method compatible with any STED scanning microscope. It exploits a data acquisition (DAQ) card based on a field-programmable gate array (FPGA), which is progressively used in STED microscopy. In essence, the FPGA-based DAQ card synchronizes the fluorescent signal registration, the beam deflection, and the excitation beam interruption, providing a fully automatic pixel-by-pixel synchronous detection method. We validate the proposed method in both continuous wave and pulsed STED microscope systems.