5 May 2017 in Science Advances
A photoacoustic microscope system provides label-free multilayered histology-like imaging of unprocessed human breast specimens.
3 January 2017 in Cancer Biology & Therapy
Using photoacoustic microscopy (PAM), we evaluated non-invasively oxygenation and vascularization in vivo due to multiple myeloma (MM) progression. Mice injected with MM.1S-GFP were monitored with a fluorescence microscope for tumor progression. In vivo PAM of the cerebral bone marrow quantified the total oxygen saturation (sO2). At 28 days after the MM cell injection, the total sO2 had decreased by half in the developing tumor regions, while in the non-tumor regions it had decreased by 20% compared with the value at one day post MM injection. The blood vessel density was reduced by 35% in the developing tumor regions, while in the non-tumor regions it was reduced by 8% compared with the value at one day post MM injection. Hence, PAM corroborated the development of hypoxia due to MM progression and demonstrated decreased vascularization surrounding the tumor areas.
18 May 2021 in BMC Musculoskeletal Disorders
Background: Strength recovery of injured knee is an important parameter for patients who want to return to sport after anterior cruciate ligament reconstruction (ACLR). Comparison of muscle strength between anatomical and non-anatomical ACLR has not been reported. Purpose: To evaluate the difference between anatomical and non-anatomical single-bundle ACLR in hamstring and quadriceps strength and clinical outcomes. Methods: Patients received unilateral primary single-bundle hamstring ACLR between January 2017 to January 2018 were recruited in this study. Patients were divided into anatomical reconstruction group (AR group) and non-anatomical reconstruction group (NAR group) according to femoral tunnel aperture position. The hamstring and quadriceps isokinetic strength including peak extension torque, peak flexion torque and H/Q ratio were measured at an angular velocity of 180°/s and 60°/s using an isokinetic dynamometer. The isometric extension and flexion torques were also measured. Hamstring and quadriceps strength were measured preoperatively and at 3, 6, and 12 months after surgery. Knee stability including Lachman test, pivot-shift test, and KT-1000 measurement and subjective knee function including International Knee Documentation Committee (IKDC) and Lysholm scores were evaluated during the follow-up. Results: Seventy-two patients with an average follow-up of 30.4 months (range, 24–35 months) were included in this study. Thirty-three were in AR group and 39 in NAR group. The peak knee flexion torque was significant higher in AR group at 180°/s and 60°/s (P < 0.05 for both velocity) at 6 months postoperatively and showed no difference between the two groups at 12 months postoperatively. The isometric knee extension torque was significant higher in AR group at 6 months postoperatively (P < 0.05) and showed no difference between the two groups at 12 months postoperatively. No significant differences between AR group and NAR group were found regarding knee stability and subjective knee function evaluations at follow-up. Conclusions: Compared with non-anatomical ACLR, anatomical ACLR showed a better recovery of hamstring and quadriceps strength at 6 months postoperatively. However, the discrepancy on hamstring and quadriceps strength between the two groups vanished at 1 year postoperatively.
1 September 2017 in Review of Scientific Instruments
A core module with a novel optical structure is presented to analyze urine by the dry-chemistry method in this paper. It consists of a 32-bit microprocessor, optical fiber bundles, a high precision color sensor and a temperature sensor. The optical fiber bundles are adopted to control the spread path of light and reduce the influence of ambient light and the distance between the strip and sensor effectively. And the temperature sensor is applied to detect the environmental temperature to calibrate the measurement results. Therefore, all these can bring a lot of benefits to the core module, such as improving its test accuracy, reducing its volume and cost, and simplifying its assembly. Additionally, some parameters, including the calculation coefficient about reflectivity of each item, semi-quantitative intervals, the number of test items, may be modified by corresponding instructions in order to enhance its applicability. Meanwhile, its outputs can be chosen among the original data, normalized color values, reflectivity, and the semi-quantitative level of each test item by available instructions. Our results show that the module has high measurement accuracy of more than 95%, good stability, reliability, and consistency and can be easily used in various types of urine analyzers.