Jiaqi Yu

Jiaqi Yu

Auto-generated profile, based on publicly available information

Jiaqi Yu

College of Electronic Information and Electrical Engineering, Changsha University,Changsha,China,410022

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
Wanli YangWanli Yang
Wanli Yang
CTChunming Tu
Chunming Tu
Fan XiaoFan Xiao
Fan Xiao
JYJiaqi Yu
Jiaqi Yu
Transient stability and frequency stability of virtual synchronous generator (VSG)-controlled converters during grid faults are critical for the stable operation of high-share renewable energy power systems. However, the existing transient stability methods often overlook the consideration of frequency stability. This paper presents a method to improve both frequency stability and transient stability of VSGs during grid faults. The influence mechanism of inertia and damping on transient stability and frequency stability is comprehensively analyzed under two types of faults, with or without stable equilibrium points. To address the conflict between frequency stability and transient stability of VSGs with large inertia under the first type of fault, an improved VSG control with angular frequency deviation feedback is proposed. The transient response of this control method is analyzed using small-signal and large-signal models. Furthermore, to achieve optimal dynamic performance, this improved VSG control introduces the optimal damping ratio and presents a parameter design method. Finally, the correctness of the proposed method and its theoretical analysis is verified through experimental results.

20 September 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
TYTianshi Yu
Tianshi Yu
HWHui Wang
Hui Wang
ZLZhengmei Lu
Zhengmei Lu
LJLi Jiang
Li Jiang
JYJiaqi Yu
Jiaqi Yu
Zhangjie LiuZhangjie Liu
Zhangjie Liu
This article presents a single-stage matrix-type solid-state transformer, which integrates a shared filter capacitor between the line frequency (LF) rectifier and the high frequency half bridge on the primary side, a modified push–pull dual active bridge to eliminate the leakage inductor effect on the secondary side, and a full-bridge LF inverter on the load side. Due to its electrolytic capacitorless nature, the proposed structure ensures identical instantaneous powers, thereby eliminating ripple power with double grid frequency, and unit power factor is inherently performed without a current control loop. Moreover, the operating characteristics of the converter under resistive and inductive–resistive loads are analyzed respectively, examining the conditions for zero voltage switching with time-varying dc-link voltage and the factors affecting total harmonic distortion. In addition, optimization strategies to reduce operating losses are considered in the parametric design. Finally, a 1 kW prototype is constructed and tested to validate the correctness and feasibility of the proposed method.

1 November 2024 in Protection and Control of Modern Power Systems
Verified
Journal Article
Closed access
JYJiaqi Yu
Jiaqi Yu
YLYong Li
Yong Li
JWJianghu Wan
Jianghu Wan
Feng ZhouFeng Zhou
Feng Zhou
MZMingmin Zhang
Mingmin Zhang
LCLihua Cao
Lihua Cao
This paper introduces a tri-state modulation technique for a soft-switching bidirectional DC-DC converter (BDC). This method maintains the soft-switching condition and introduces a freewheeling interval that reduces the rise and fall times of the inductor current, effectively suppressing inductor current ripples. Additionally, the tri-state modulation provides an extra degree of freedom, enabling optimization for reduced operating losses. The paper details the operation principles of tri-state modulation in both buck and boost modes and discusses optimization strategies for minimizing losses. An experimental setup is developed to validate the tri-state modulation approach, where switching waveforms and efficiency are measured. The experimental results confirm that the proposed method achieves soft-switching conditions, suppresses inductor current ripples, and provides higher efficiency compared to conventional hard-switching BDC and typical soft-switching BDC.