Moisture accumulates with the growing aging progress of oil-paper insulation and further shortens the remaining life of the transformer. The frequency-domain spectroscopy (FDS) technique can be used to realize the moisture estimation. However, the moisture estimation results would be unreliable once the aging effect on FDS was ignored. Given this issue, an alternative model including the aging effect is thus proposed using FDS and intelligent algorithm. In this work, the feature parameters of FDS data are used to build the databases for characterizing the aging degree and moisture. Then, the moisture estimation models are developed using the weighted K-nearest neighbor (K-NN) algorithm. The accuracy and applicability of the proposed models are finally discussed in laboratory and field conditions. In that respect, the findings reveal that the reported model is available for moisture estimation of transformer oil-paper insulation under various aging degrees and test temperatures.
8 February 2021 in IEEE Transactions on Instrumentation and Measurement
The influence of nonuniform aging has not been considered in the prediction of the frequency domain spectroscopy (FDS) of the transformer oil-paper insulation (OPI) when using the finite element method (FEM). Given this issue, the modified simulation model was constructed based on the XY model and FEM. In the current work, the dielectric response property of the pressboards with different aging conditions in the modified model was characterized by its dielectric response parameters measured in the lab. Then the modified simulation model constructed in a 3-D system would be applied to study the effect of both nonuniform aging and the axial geometry on the FDS of OPI. Finally, the feasibility of the proposed models was verified by comparing the measured FDS and the predicted FDS. This article is expected to provide a model for predicting the FDS of the transformer OPI including the effect of nonuniform aging.
Frequency domain spectroscopy (FDS) technique is widely applied in the condition assessment of the oil-paper system in power transformers. However, the synergistic effect generated by moisture and temperature on the FDS data cannot be analyzed by the existing model since the single independent variable (moisture or temperature) is considered in the construction of the model. To quantify such the synergistic effect, a novel method that utilized for normalizing (or standardizing) the FDS curve is reported based on the theory of the power series and fitting analysis. The present findings reveal that the reported method is capable of predicting the dielectric loss (tanδ) curve under diverse test conditions, in which the average error is less than 7%. The synergistic effect can be also explored by using the extracted feature parameters. The potential application is then proved to make up for the measurement errors during the FDS test, the findings are expected to promote the moisture analysis of the transformer insulation.