Metabolic stress is an important cause of pathological atrial remodeling and atrial fibrillation. AMPK is a ubiquitous master metabolic regulator, yet its biological function in the atria is poorly understood in both health and disease. We investigated the impact of atrium-selective cardiac AMPK deletion on electrophysiological and structural remodeling in mice. Loss of atrial AMPK expression caused atrial changes in electrophysiological properties and atrial ectopic activity prior to the onset of spontaneous atrial fibrillation. Concomitant transcriptional downregulation of connexins and atrial ion channel subunits manifested with delayed left atrial activation and repolarization. The early molecular and electrophysiological abnormalities preceded left atrial structural remodeling and interstitial fibrosis. AMPK inactivation induced downregulation of transcription factors ( Mef2c and Pitx2c ) linked to connexin and ion channel transcriptional reprogramming. Thus, AMPK plays an essential homeostatic role in atria, protecting against adverse remodeling potentially by regulating key transcription factors that control the expression of atrial ion channels and gap junction proteins.
17 January 2024 in IEEE Transactions on Medical Imaging
Characterizing left ventricular deformation and strain using 3D+time echocardiography provides useful insights into cardiac function and can be used to detect and localize myocardial injury. To achieve this, it is imperative to obtain accurate motion estimates of the left ventricle. In many strain analysis pipelines, this step is often accompanied by a separate segmentation step; however, recent works have shown both tasks to be highly related and can be complementary when optimized jointly. In this work, we present a multi-task learning network that can simultaneously segment the left ventricle and track its motion between multiple time frames. Two task-specific networks are trained using a composite loss function. Cross-stitch units combine the activations of these networks by learning shared representations between the tasks at different levels. We also propose a novel shape-consistency unit that encourages motion propagated segmentations to match directly predicted segmentations. Using a combined synthetic and in-vivo 3D echocardiography dataset, we demonstrate that our proposed model can achieve excellent estimates of left ventricular motion displacement and myocardial segmentation. Additionally, we observe strong correlation of our image-based strain measurements with crystal-based strain measurements as well as good correspondence with SPECT perfusion mappings. Finally, we demonstrate the clinical utility of the segmentation masks in estimating ejection fraction and sphericity indices that correspond well with benchmark measurements.
30 June 2022 in IEEE Transactions on Radiation and Plasma Medical Sciences
Convolutional neural networks (CNNs) have been extremely successful in various medical imaging tasks. However, because the size of the convolutional kernel used in a CNN is much smaller than the image size, CNN has a strong spatial inductive bias and lacks a global understanding of the input images. Vision Transformer, a recently emerged network structure in computer vision, can potentially overcome the limitations of CNNs for image-reconstruction tasks. In this work, we proposed a slice-by-slice Transformer network (SSTrans-3D) to reconstruct cardiac single-photon emission computed tomography (SPECT) images from 3-D few-angle data. To be specific, the network reconstructs the whole 3-D volume using a slice-by-slice scheme. By doing so, SSTrans-3D alleviates the memory burden required by 3-D reconstructions using Transformer. The network can still obtain a global understanding of the image volume with the Transformer attention blocks. Finally, already reconstructed slices are used as the input to the network so that SSTrans-3D can potentially obtain more informative features from these slices. Validated on porcine, phantom, and human studies acquired using a GE dedicated cardiac SPECT scanner, the proposed method produced images with clearer heart cavity, higher cardiac defect contrast, and more accurate quantitative measurements on the testing data as compared with a deep U-net.
1 December 2016 in Journal of Cardiovascular Magnetic Resonance
High resolution 3D T1 mapping is important for assessment of diffuse myocardial fibrosis in left atrium or other thin-walled structures. In this work, we investigated a fast single-TI 3D high resolution T1 mapping method that directly transforms a 3D late gadolinium enhancement (LGE) volume to a 3D T1 map. The proposed method, T1-refBlochi, is based on Bloch equation modeling of the LGE signal, a single-point calibration, and assumptions that proton density and T2* are relatively uniform in the heart. Several sources of error of this method were analyzed mathematically and with simulations. Imaging was performed in phantoms, eight swine and five patients, comparing T1-refBlochi to a standard spin-echo T1 mapping, 3D multi-TI T1 mapping, and 2D ShMOLLI, respectively. The method has a good accuracy and adequate precision, even considering various sources of error. In phantoms, over a range of protocols, heart-rates and T1 s, the bias ±1SD was -3 ms ± 9 ms. The porcine studies showed excellent agreement between T1-refBlochi and the multi-TI method (bias ±1SD = −6 ± 22 ms). The proton density and T2* weightings yielded ratios for scar/blood of 0.94 ± 0.01 and for myocardium/blood of 1.03 ± 0.02 in the eight swine, confirming that sufficient uniformity of proton density and T2* weightings exists among heterogeneous tissues of the heart. In the patients, the mean T1 bias ±1SD in myocardium and blood between T1-refBlochi and ShMOLLI was -9 ms ± 21 ms. T1-refBlochi provides a fast single-TI high resolution 3D T1 map of the heart with good accuracy and adequate precision.
10 June 2019 in IEEE Transactions on Medical Imaging
Recently introduced stationary dedicated cardiac SPECT scanners provide new opportunities to quantify myocardial blood flow (MBF) using dynamic SPECT. However, comparing to PET, the low sensitivity of SPECT scanners affects MBF quantification due to the high noise level, especially for 201 Thallium ( 201 Tl) due to its typically low injected dose. The conventional indirect method for generating parametric images typically starts by reconstructing a time series of frame images followed by fitting the time-activity curve (TAC) for each voxel or segment with an appropriate kinetic model. The indirect method is simple and easy to implement; however, it usually suffers from substantial image noise that could also lead to bias. In this paper, we developed a list mode direct parametric image reconstruction algorithm to substantially reduce noise in MBF quantification using dynamic SPECT and allow for patient radiation dose reduction. GPU-based parallel computing was used to achieve more than 2000-fold acceleration. The proposed method was evaluated in both simulation and in vivo canine studies. Compared with the indirect method, the proposed direct method achieved substantially lower image noise and variability, particularly at large number of iterations and at low-count levels.