1 December 2016 in Scientific Reports
Natural and synthetic hydrogel scaffolds exhibit distinct viscoelastic properties at various length scales and deformation rates. Laser Speckle Rheology (LSR) offers a novel, non-contact optical approach for evaluating the frequency-dependent viscoelastic properties of hydrogels. In LSR, a coherent laser beam illuminates the specimen and a high-speed camera acquires the time-varying speckle images. Cross-correlation analysis of frames returns the speckle intensity autocorrelation function, g2(t), from which the frequency-dependent viscoelastic modulus, G*(ω), is deduced. Here, we establish the capability of LSR for evaluating the viscoelastic properties of hydrogels over a large range of moduli, using conventional mechanical rheometry and atomic force microscopy (AFM)-based indentation as reference-standards. Results demonstrate a strong correlation between |G*(ω)| values measured by LSR and mechanical rheometry (r = 0.95, p < 10−9), and z-test analysis reports that moduli values measured by the two methods are identical (p > 0.08) over a large range (47 Pa – 36 kPa). In addition, |G*(ω)| values measured by LSR correlate well with indentation moduli, E, reported by AFM (r = 0.92, p < 10−7). Further, spatially-resolved moduli measurements in micro-patterned substrates demonstrate that LSR combines the strengths of conventional rheology and micro-indentation in assessing hydrogel viscoelastic properties at multiple frequencies and small length-scales.
4 November 2014 in Biomedical Optics Express
Over the years, many computed optical interferometric techniques have been developed to perform high-resolution volumetric tomography. By utilizing the phase and amplitude information provided with interferometric detection, post-acquisition corrections for defocus and optical aberrations can be performed. The introduction of the phase, though, can dramatically increase the sensitivity to motion (most prominently along the optical axis). In this paper, we present two algorithms which, together, can correct for motion in all three dimensions with enough accuracy for defocus and aberration correction in computed optical interferometric tomography. The first algorithm utilizes phase differences within the acquired data to correct for motion along the optical axis. The second algorithm utilizes the addition of a speckle tracking system using temporally- and spatially-coherent illumination to measure motion orthogonal to the optical axis. The use of coherent illumination allows for high-contrast speckle patterns even when imaging apparently uniform samples or when highly aberrated beams cannot be avoided.
9 December 2022 in Medical Image Analysis
11 July 2023 in IEEE Transactions on Medical Imaging
Automated volumetric meshing of patient-specific heart geometry can help expedite various biomechanics studies, such as post-intervention stress estimation. Prior meshing techniques often neglect important modeling characteristics for successful downstream analyses, especially for thin structures like the valve leaflets. In this work, we present DeepCarve (Deep Cardiac Volumetric Mesh): a novel deformation-based deep learning method that automatically generates patient-specific volumetric meshes with high spatial accuracy and element quality. The main novelty in our method is the use of minimally sufficient surface mesh labels for precise spatial accuracy and the simultaneous optimization of isotropic and anisotropic deformation energies for volumetric mesh quality. Mesh generation takes only 0.13 seconds/scan during inference, and each mesh can be directly used for finite element analyses without any manual post-processing. Calcification meshes can also be subsequently incorporated for increased simulation accuracy. Numerous stent deployment simulations validate the viability of our approach for large-batch analyses. Our code is available at https://github.com/danpak94/Deep-Cardiac-Volumetric-Mesh .
17 January 2024 in IEEE Transactions on Medical Imaging
Characterizing left ventricular deformation and strain using 3D+time echocardiography provides useful insights into cardiac function and can be used to detect and localize myocardial injury. To achieve this, it is imperative to obtain accurate motion estimates of the left ventricle. In many strain analysis pipelines, this step is often accompanied by a separate segmentation step; however, recent works have shown both tasks to be highly related and can be complementary when optimized jointly. In this work, we present a multi-task learning network that can simultaneously segment the left ventricle and track its motion between multiple time frames. Two task-specific networks are trained using a composite loss function. Cross-stitch units combine the activations of these networks by learning shared representations between the tasks at different levels. We also propose a novel shape-consistency unit that encourages motion propagated segmentations to match directly predicted segmentations. Using a combined synthetic and in-vivo 3D echocardiography dataset, we demonstrate that our proposed model can achieve excellent estimates of left ventricular motion displacement and myocardial segmentation. Additionally, we observe strong correlation of our image-based strain measurements with crystal-based strain measurements as well as good correspondence with SPECT perfusion mappings. Finally, we demonstrate the clinical utility of the segmentation masks in estimating ejection fraction and sphericity indices that correspond well with benchmark measurements.
16 March 2020 in Proceedings of SPIE
Accurate motion tracking of the left ventricle is critical in detecting wall motion abnormalities in the heart after an injury such as a myocardial infarction. We propose an unsupervised motion tracking framework with physiological constraints to learn dense displacement fields between sequential pairs of 2-D B-mode echocardiography images. Current deep-learning motion-tracking algorithms require large amounts of data to provide ground-truth, which is difficult to obtain for in vivo datasets (such as patient data and animal studies), or are unsuccessful in tracking motion between echocardiographic images due to inherent ultrasound properties (such as low signal-to-noise ratio and various image artifacts). We design a U-Net inspired convolutional neural network that uses manually traced segmentations as a guide to learn displacement estimations between a source and target image without ground- truth displacement fields by minimizing the difference between a transformed source frame and the original target frame. We then penalize divergence in the displacement field in order to enforce incompressibility within the left ventricle. We demonstrate the performance of our model on synthetic and in vivo canine 2-D echocardiography datasets by comparing it against a non-rigid registration algorithm and a shape-tracking algorithm. Our results show favorable performance of our model against both methods.