Giuseppe Puglisi

Giuseppe Puglisi

Auto-generated profile, based on publicly available information

Giuseppe Puglisi

Istituto Nazionale di Geofisica e Vulcanologia, Osservatorio Etneo, Sezione di Catania, Catania, Italy

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2011 in Geochemistry, Geophysics, Geosystems
Verified
Journal Article
Closed access
PDF file
Alessandro BonforteAlessandro Bonforte
Alessandro Bonforte
FGFrancesco Guglielmino
Francesco Guglielmino
MCMauro Coltelli
Mauro Coltelli
AFAlessandro Ferretti
Alessandro Ferretti
GPGiuseppe Puglisi
Giuseppe Puglisi

16 May 2008 in Journal of Geophysical Research
Verified
Journal Article
Closed access
PDF file
ABAlessandro Bonaccorso
Alessandro Bonaccorso
FGFrancesco Guglielmino
Francesco Guglielmino
Mimmo PalanoMimmo Palano
Mimmo Palano
GPGiuseppe Puglisi
Giuseppe Puglisi

1 January 1996 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
RLR. Lanari
R. Lanari
GFG. Fornaro
G. Fornaro
Daniele RiccioDaniele Riccio
Daniele Riccio
Maurizio  MigliaccioMaurizio Migliaccio
Maurizio Migliaccio
KPK.P. Papathanassiou
K.P. Papathanassiou
MCMauro Coltelli
Mauro Coltelli
The authors exploit the interferometric multifrequency potentiality of the SIR-C/X-SAR system which is equipped with an L-, C-, and X-band sensor. They present a solution to improve the unwrapping performance of the C- and X-band data by considering the L-band unwrapped pattern. A new algorithm for the generation of a single digital elevation model (DEM) combining L-, C-, and X-band information is presented. This solution is based on the fusion of the unwrapped phase patterns by using a Kalman filter. The proposed fusion operation also accounts for the coherence characteristics of the three data sets. The selected test site is the Mt. Etna region in Italy which is very interesting from the volcanological and geological point of view. Numerical assessments of the achieved results are provided by evaluating the height accuracy with respect to a reference DE

3 October 2002 in Geophysical Research Letters
Verified
Journal Article
Open access
PDF file
GWG. Wadge
G. Wadge
Peter WebleyPeter Webley
Peter Webley
IJI. N. James
I. N. James
RBR. Bingley
R. Bingley
ADA. Dodson
A. Dodson
PCPeter Clarke
Peter Clarke
Dynamic models of atmospheric movement over the Mount Etna volcano are used to calculate the path delays affecting radar caused by variable water vapour in the troposphere. We compare these model results with the equivalent differential radar interferogram generated by two ERS‐2 SAR images taken 35 days apart and the water vapour delay retrievals from a network of fourteen GPS stations distributed over the volcano. The atmospheric model delay field agrees well with the long‐wavelength spatial differences measured by InSAR and those measured by GPS.

30 March 2007 in Cytometry Part B: Clinical Cytometry
Verified
Journal Article
Open access
PDF file
MCMaria Bernadette Colombo
Maria Bernadette Colombo
SHSimone Elisabeth Haworth
Simone Elisabeth Haworth
FPFrancesca Poli
Francesca Poli
ANAngela Nocco
Angela Nocco
GPGiuseppe Puglisi
Giuseppe Puglisi
MSMario Scalamogna
Mario Scalamogna
The recent introduction of new technologies such as Luminex has provided alternative methods to the Complement Dependent Cytotoxicity (CDC) test for HLA specific antibody detection. In this study we compared the results obtained with CDC to those obtained using a Luminex method with the aim of evaluating the impact of this new technology on antibody screening policies in our transplant setting.A total of 1,421 sera, acquired from patients on the waiting list for a kidney transplant or following transplantation, were tested by both methodologies. CDC was performed using a whole lymphocyte population comprising a panel of 52 cells. The percentage panel reactive antibodies (PRA) and antibody specificity were evaluated using Lambda Scan Analysis software. For the Luminex method sera screening and identification of antibody specificity were carried out using the LABScreen Mixed and LABScreen PRA respectively.The overall concordance between the results obtained using the CDC and the Luminex methods was 85%. HLA antibody specificity was confirmed in 96% of the sera which tested positive using the Luminex system and serum positivity corresponded with a previous sensitisation event in these individuals. Using the Luminex method 18% of patients on the waiting list were considered and managed as sensitised as compared to 7% when testing with CDC alone. The Luminex method was able to detect a number of antibody specificities significantly more frequently than the CDC method and in addition the CDC method failed to detect some of the antibody specificities detected by the Luminex system.Based on this comparison study we have incorporated the Luminex methodology into our screening strategy. © 2007 Clinical Cytometry Society

10 February 2011 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
FGFrancesco Guglielmino
Francesco Guglielmino
GNGiuseppe Nunnari
Giuseppe Nunnari
GPGiuseppe Puglisi
Giuseppe Puglisi
ASAlessandro Spata
Alessandro Spata
We propose a new technique, named SISTEM, based on the elastic theory, to efficiently estimate 3-D displacements for producing deformation maps by integrating sparse Global Positioning System (GPS) measurements of deformations and differential interferometric synthetic aperture radar (DInSAR) maps of movements of the Earth's surface. Previous approaches in the literature to combine GPS and DInSAR data require two steps: a first step in which sparse GPS measurements are interpolated in order to fill in GPS displacements in the DInSAR grid and a second step to estimate the 3-D surface displacement maps by using a suitable optimization technique. One of the advantages of the proposed approach, compared to previous ones, is that it does not require the preliminary interpolation of the observed deformation pattern. Indeed, we propose a linear matrix equation which accounts for both the GPS and DInSAR data whose solution simultaneously provides the strain tensor, the displacement field, and the rigid body rotation tensor. The mentioned linear matrix equation is solved by using the weighted least square (WLS), thus assuring both numerical robustness and high computation efficiency. The methodology was tested on both synthetic and experimental data, these last from GPS and DInSAR measurements carried out on Mount Etna during the 2003-2004 period. In order to appreciate the accuracy of the results, the estimated standard errors computed by the WLS are provided. These tests also allow optimizing the choice of specific parameters of this algorithm. This method can be further exploited to account for other available data sets, such as additional interferograms or other geodetic data (e.g., leveling, tilt, etc.), in order to achieve higher accuracy.