Muhummad Sohaib Nazir

Muhummad Sohaib Nazir

Auto-generated profile, based on publicly available information

Muhummad Sohaib Nazir

Cardio-Oncology Service and Cardio-Oncology Centre of Excellence, Royal Brompton Hospital, London, United Kingdom; School of Biomedical Engineering and Imaging Sciences, King's College London, Guy's and St Thomas' Hospital, London, United Kingdom

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
AVAdriana D. M. Villa
Adriana D. M. Villa
LCLaura Corsinovi
Laura Corsinovi
INIOANNIS NTALAS
IOANNIS NTALAS
XMXenios Milidonis
Xenios Milidonis
CSCian M. Scannell
Cian M. Scannell
ACAmedeo Chiribiri
Amedeo Chiribiri
Clinical evaluation of stress perfusion cardiovascular magnetic resonance (CMR) is currently based on visual assessment and has shown high diagnostic accuracy in previous clinical trials, when performed by expert readers or core laboratories. However, these results may not be generalizable to clinical practice, particularly when less experienced readers are concerned. Other factors, such as the level of training, the extent of ischemia, and image quality could affect the diagnostic accuracy. Moreover, the role of rest images has not been clarified. The aim of this study was to assess the diagnostic accuracy of visual assessment for operators with different levels of training and the additional value of rest perfusion imaging, and to compare visual assessment and automated quantitative analysis in the assessment of coronary artery disease (CAD). We evaluated 53 patients with known or suspected CAD referred for stress-perfusion CMR. Nine operators (equally divided in 3 levels of competency) blindly reviewed each case twice with a 2-week interval, in a randomised order, with and without rest images. Semi-automated Fermi deconvolution was used for quantitative analysis and estimation of myocardial perfusion reserve as the ratio of stress to rest perfusion estimates. Level-3 operators correctly identified significant CAD in 83.6% of the cases. This percentage dropped to 65.7% for Level-2 operators and to 55.7% for Level-1 operators (p < 0.001). Quantitative analysis correctly identified CAD in 86.3% of the cases and was non-inferior to expert readers (p = 0.56). When rest images were available, a significantly higher level of confidence was reported (p = 0.022), but no significant differences in diagnostic accuracy were measured (p = 0.34). Our study demonstrates that the level of training is the main determinant of the diagnostic accuracy in the identification of CAD. Level-3 operators performed at levels comparable with the results from clinical trials. Rest images did not significantly improve diagnostic accuracy, but contributed to higher confidence in the results. Automated quantitative analysis performed similarly to level-3 operators. This is of increasing relevance as recent technical advances in image reconstruction and analysis techniques are likely to permit the clinical translation of robust and fully automated quantitative analysis into routine clinical practice.

1 February 2018 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
MNMuhummad Sohaib Nazir
Muhummad Sohaib Nazir
RNRadhouene Neji
Radhouene Neji
PSPeter Speier
Peter Speier
FRFiona Reid
Fiona Reid
DSDaniel Stäb
Daniel Stäb
SRSωbastien Roujol
Sωbastien Roujol
Simultaneous-Multi-Slice (SMS) perfusion imaging has the potential to acquire multiple slices, increasing myocardial coverage without sacrificing in-plane spatial resolution. To maximise signal-to-noise ratio (SNR), SMS can be combined with a balanced steady state free precession (bSSFP) readout. Furthermore, application of gradient-controlled local Larmor adjustment (GC-LOLA) can ensure robustness against off-resonance artifacts and SNR loss can be mitigated by applying iterative reconstruction with spatial and temporal regularisation. The objective of this study was to compare cardiovascular magnetic resonance (CMR) myocardial perfusion imaging using SMS bSSFP imaging with GC-LOLA and iterative reconstruction to 3 slice bSSFP. Two contrast-enhanced rest perfusion sequences were acquired in random order in 8 patients: 6-slice SMS bSSFP and 3 slice bSSFP. All images were reconstructed with TGRAPPA. SMS images were also reconstructed using a non-linear iterative reconstruction with L1 regularisation in wavelet space (SMS-iter) with 7 different combinations for spatial (λσ) and temporal (λτ) regularisation parameters. Qualitative ratings of overall image quality (0 = poor image quality, 1 = major artifact, 2 = minor artifact, 3 = excellent), perceived SNR (0 = poor SNR, 1 = major noise, 2 = minor noise, 3 = high SNR), frequency of sequence related artifacts and patient related artifacts were undertaken. Quantitative analysis of contrast ratio (CR) and percentage of dark rim artifact (DRA) was performed. Among all SMS-iter reconstructions, SMS-iter 6 (λσ 0.001 λτ 0.005) was identified as the optimal reconstruction with the highest overall image quality, least sequence related artifact and higher perceived SNR. SMS-iter 6 had superior overall image quality (2.50 ± 0.53 vs 1.50 ± 0.53, p = 0.005) and perceived SNR (2.25 ± 0.46 vs 0.75 ± 0.46, p = 0.010) compared to 3 slice bSSFP. There were no significant differences in sequence related artifact, CR (3.62 ± 0.39 vs 3.66 ± 0.65, p = 0.88) or percentage of DRA (5.25 ± 6.56 vs 4.25 ± 4.30, p = 0.64) with SMS-iter 6 compared to 3 slice bSSFP. SMS bSSFP with GC-LOLA and iterative reconstruction improved image quality compared to a 3 slice bSSFP with doubled spatial coverage and preserved in-plane spatial resolution. Future evaluation in patients with coronary artery disease is warranted.

24 March 2011 in Chronic Respiratory Disease
Verified
Journal Article
Open access
EPElspeth E Pickering
Elspeth E Pickering
SSStephen J Semple
Stephen J Semple
MNMuhummad S Nazir
Muhummad S Nazir
KMKevin Murphy
Kevin Murphy
TSThomas M Snow
Thomas M Snow
AHAnita Holdcroft
Anita Holdcroft
Based on the neurophysiology of dyspnoea and the distribution of cannabinoid receptors within the central nervous system, we hypothesize that the unpleasantness of breathlessness will be ameliorated in humans by cannabinoids, without respiratory depression. Five normal and four chronic obstructive pulmonary disease (COPD) subjects entered a double blind, randomized, placebo-controlled crossover study with two test days. Subjects received sublingual cannabis extract or placebo. A maximum of 10.8 mg tetrahydrocannabinol and 10 mg cannabidiol were given. Breathlessness was simulated using fixed carbon dioxide loads. Measurements taken were of breathlessness (visual analogue scale [VAS] and breathlessness descriptors), mood and activation, end-tidal carbon dioxide tension and ventilatory parameters. These were measured at baseline and 2 hours post placebo and drug administration. Normal and COPD subjects showed no differences in breathlessness VAS scores and respiratory measurements before and after placebo or drug. After drug administration, COPD subjects picked ‘air hunger’ breathlessness descriptors less frequently compared to placebo. We have shown that breathlessness descriptors may detect an amelioration of the unpleasantness of breathlessness by cannabinoids without a change in conventional breathlessness ratings (VAS). A stimulus more specific for air hunger may be needed to demonstrate directly a drug effect on breathlessness. However, this study shows that the inclusion of respiratory descriptors may contribute to the assessment of drug effects on breathlessness.

5 January 2021 in Heart
Verified
Journal Article
Closed access
PDF file
ACAmrit Chowdhary
Amrit Chowdhary
PGPankaj Garg
Pankaj Garg
ADArka Das
Arka Das
MNMuhummad Sohaib Nazir
Muhummad Sohaib Nazir
SPSven Plein
Sven Plein
This review gives examples of emerging cardiovascular magnetic resonance (CMR) techniques and applications that have the potential to transition from research to clinical application in the near future. Four-dimensional flow CMR (4D-flow CMR) allows time-resolved three-directional, three-dimensional (3D) velocity-encoded phase-contrast imaging for 3D visualisation and quantification of valvular or intracavity flow. Acquisition times of under 10 min are achievable for a whole heart multidirectional data set and commercial software packages are now available for data analysis, making 4D-flow CMR feasible for inclusion in clinical imaging protocols. Diffusion tensor imaging (DTI) is based on the measurement of molecular water diffusion and uses contrasting behaviour in the presence and absence of boundaries to infer tissue structure. Cardiac DTI is capable of non-invasively phenotyping the 3D micro-architecture within a few minutes, facilitating transition of the method to clinical protocols. Hybrid positron emission tomography-magnetic resonance (PET-MR) provides quantitative PET measures of biological and pathological processes of the heart combined with anatomical, morphological and functional CMR imaging. Cardiac PET-MR offers opportunities in ischaemic, inflammatory and infiltrative heart disease.

11 April 2022 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
MNMuhummad Sohaib Nazir
Muhummad Sohaib Nazir
ABAurélien Bustin
Aurélien Bustin
RHReza Hajhosseiny
Reza Hajhosseiny
MYMomina Yazdani
Momina Yazdani
MRMatthew Ryan
Matthew Ryan
CPClaudia Prieto
Claudia Prieto
Coronary artery disease (CAD) is the single most common cause of death worldwide. Recent technological developments with coronary cardiovascular magnetic resonance angiography (CCMRA) allow high-resolution free-breathing imaging of the coronary arteries at submillimeter resolution without contrast in a predictable scan time of ~ 10 min. The objective of this study was to determine the diagnostic accuracy of high-resolution CCMRA for CAD detection against the gold standard of invasive coronary angiography (ICA). Forty-five patients (15 female, 62 ± 10 years) with suspected CAD underwent sub-millimeter-resolution (0.6 mm3) non-contrast CCMRA at 1.5T in this prospective clinical study from 2019–2020. Prior to CCMR, patients were given an intravenous beta blockers to optimize heart rate control and sublingual glyceryl trinitrate to promote coronary vasodilation. Obstructive CAD was defined by lesions with ≥ 50% stenosis by quantitative coronary angiography on ICA. The mean duration of image acquisition was 10.4 ± 2.1 min. On a per patient analysis, the sensitivity, specificity, positive predictive value and negative predictive value (95% confidence intervals) were 95% (75–100), 54% (36–71), 60% (42–75) and 93% (70–100), respectively. On a per vessel analysis the sensitivity, specificity, positive predictive value and negative predictive value (95% confidence intervals) were 80% (63–91), 83% (77–88), 49% (36–63) and 95% (90–98), respectively. As an important step towards clinical translation, we demonstrated a good diagnostic accuracy for CAD detection using high-resolution CCMRA, with high sensitivity and negative predictive value. The positive predictive value is moderate, and combination with CMR stress perfusion may improve the diagnostic accuracy. Future multicenter evaluation is now required.

12 June 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
SMSarah McElroy
Sarah McElroy
GFGiulio Ferrazzi
Giulio Ferrazzi
MNMuhummad Sohaib Nazir
Muhummad Sohaib Nazir
KKKarl P. Kunze
Karl P. Kunze
RNRadhouene Neji
Radhouene Neji
SRSébastien Roujol
Sébastien Roujol
Purpose: To implement and evaluate a pseudorandom undersampling scheme for combined simultaneous multislice (SMS) balanced SSFP (bSSFP) and compressed‐sensing (CS) reconstruction to enable myocardial perfusion imaging with high spatial resolution and coverage at 1.5 T.Methods: A prospective pseudorandom undersampling scheme that is compatible with SMS‐bSSFP phase‐cycling requirements and CS was developed. The SMS‐bSSFP CS with pseudorandom and linear undersampling schemes were compared in a phantom. A high‐resolution (1.4 × 1.4 mm2) six‐slice SMS‐bSSFP CS perfusion sequence was compared with a conventional (1.9 × 1.9 mm2) three‐slice sequence in 10 patients. Qualitative assessment of image quality, perceived SNR, and number of diagnostic segments and quantitative measurements of sharpness, upslope index, and contrast ratio were performed.Results: In phantom experiments, pseudorandom undersampling resulted in residual artifact (RMS error) reduction by a factor of 7 compared with linear undersampling. In vivo, the proposed sequence demonstrated higher perceived SNR (2.9 ± 0.3 vs. 2.2 ± 0.6, P = .04), improved sharpness (0.35 ± 0.03 vs. 0.32 ± 0.05, P = .01), and a higher number of diagnostic segments (100% vs. 94%, P = .03) compared with the conventional sequence. There were no significant differences between the sequences in terms of image quality (2.5 ± 0.4 vs. 2.8 ± 0.2, P = .08), upslope index (0.11 ± 0.02 vs. 0.10 ± 0.01, P = .3), or contrast ratio (3.28 ± 0.35 vs. 3.36 ± 0.43, P = .7).Conclusion: A pseudorandom k‐space undersampling compatible with SMS‐bSSFP and CS reconstruction has been developed and enables cardiac MR perfusion imaging with increased spatial resolution and myocardial coverage, increased number of diagnostic segments and perceived SNR, and no difference in image quality, upslope index, and contrast ratio.