Sarah McElroy

Sarah McElroy

Auto-generated profile, based on publicly available information

Sarah McElroy

Research Department of Imaging Physics and Engineering School of Biomedical Engineering and Imaging Sciences, King's College London London UK

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
SMSarah McElroy
Sarah McElroy
GFGiulio Ferrazzi
Giulio Ferrazzi
MNMuhummad Sohaib Nazir
Muhummad Sohaib Nazir
KKKarl P. Kunze
Karl P. Kunze
RNRadhouene Neji
Radhouene Neji
SRSébastien Roujol
Sébastien Roujol
Purpose: To implement and evaluate a pseudorandom undersampling scheme for combined simultaneous multislice (SMS) balanced SSFP (bSSFP) and compressed‐sensing (CS) reconstruction to enable myocardial perfusion imaging with high spatial resolution and coverage at 1.5 T.Methods: A prospective pseudorandom undersampling scheme that is compatible with SMS‐bSSFP phase‐cycling requirements and CS was developed. The SMS‐bSSFP CS with pseudorandom and linear undersampling schemes were compared in a phantom. A high‐resolution (1.4 × 1.4 mm2) six‐slice SMS‐bSSFP CS perfusion sequence was compared with a conventional (1.9 × 1.9 mm2) three‐slice sequence in 10 patients. Qualitative assessment of image quality, perceived SNR, and number of diagnostic segments and quantitative measurements of sharpness, upslope index, and contrast ratio were performed.Results: In phantom experiments, pseudorandom undersampling resulted in residual artifact (RMS error) reduction by a factor of 7 compared with linear undersampling. In vivo, the proposed sequence demonstrated higher perceived SNR (2.9 ± 0.3 vs. 2.2 ± 0.6, P = .04), improved sharpness (0.35 ± 0.03 vs. 0.32 ± 0.05, P = .01), and a higher number of diagnostic segments (100% vs. 94%, P = .03) compared with the conventional sequence. There were no significant differences between the sequences in terms of image quality (2.5 ± 0.4 vs. 2.8 ± 0.2, P = .08), upslope index (0.11 ± 0.02 vs. 0.10 ± 0.01, P = .3), or contrast ratio (3.28 ± 0.35 vs. 3.36 ± 0.43, P = .7).Conclusion: A pseudorandom k‐space undersampling compatible with SMS‐bSSFP and CS reconstruction has been developed and enables cardiac MR perfusion imaging with increased spatial resolution and myocardial coverage, increased number of diagnostic segments and perceived SNR, and no difference in image quality, upslope index, and contrast ratio.

22 April 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
SSSara Neves Silva
Sara Neves Silva
SMSarah McElroy
Sarah McElroy
JVJordina Aviles Verdera
Jordina Aviles Verdera
KCKathleen Colford
Kathleen Colford
KCKamilah St Clair
Kamilah St Clair
JHJana Hutter
Jana Hutter
Purpose: Widening the availability of fetal MRI with fully automatic real‐time planning of radiological brain planes on 0.55T MRI.Methods: Deep learning‐based detection of key brain landmarks on a whole‐uterus echo planar imaging scan enables the subsequent fully automatic planning of the radiological single‐shot Turbo Spin Echo acquisitions. The landmark detection pipeline was trained on over 120 datasets from varying field strength, echo times, and resolutions and quantitatively evaluated. The entire automatic planning solution was tested prospectively in nine fetal subjects between 20 and 37 weeks. A comprehensive evaluation of all steps, the distance between manual and automatic landmarks, the planning quality, and the resulting image quality was conducted.Results: Prospective automatic planning was performed in real‐time without latency in all subjects. The landmark detection accuracy was 4.2 2.6 mm for the fetal eyes and 6.5 3.2 for the cerebellum, planning quality was 2.4/3 (compared to 2.6/3 for manual planning) and diagnostic image quality was 2.2 compared to 2.1 for manual planning.Conclusions: Real‐time automatic planning of all three key fetal brain planes was successfully achieved and will pave the way toward simplifying the acquisition of fetal MRI thereby widening the availability of this modality in nonspecialist centers.

25 March 2024 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
RCR Crawley
R Crawley
KKK P Kunze
K P Kunze
XMX Milidonis
X Milidonis
JHJ Highton
J Highton
SMS McElroy
S McElroy
ACAmedeo Chiribiri
Amedeo Chiribiri
Current assessment of myocardial ischaemia from stress perfusion cardiovascular magnetic resonance (SP-CMR) largely relies on visual interpretation. This study investigated the use of high-resolution free-breathing SP-CMR with automated quantitative mapping in the diagnosis of coronary artery disease (CAD). Diagnostic performance was evaluated against invasive coronary angiography (ICA) with fractional flow reserve (FFR) measurement. Seven hundred and three patients were recruited for SP-CMR using the research sequence at 3 Tesla. Of those receiving ICA within 6 months, 80 patients had either FFR measurement or identification of a chronic total occlusion (CTO) with inducible perfusion defects seen on SP-CMR. Myocardial blood flow (MBF) maps were automatically generated in-line on the scanner following image acquisition at hyperaemic stress and rest, allowing myocardial perfusion reserve (MPR) calculation. Seventy-five coronary vessels assessed by FFR and 28 vessels with CTO were evaluated at both segmental and coronary territory level. Coronary territory stress MBF and MPR were reduced in FFR-positive (≤0.80) regions [median stress MBF: 1.74 (0.90–2.17) mL/min/g; MPR: 1.67 (1.10–1.89)] compared with FFR-negative regions [stress MBF: 2.50 (2.15–2.95) mL/min/g; MPR 2.35 (2.06–2.54) P < 0.001 for both]. Stress MBF ≤ 1.94 mL/min/g and MPR ≤ 1.97 accurately detected FFR-positive CAD on a per-vessel basis (area under the curve: 0.85 and 0.96, respectively; P < 0.001 for both). A novel scanner-integrated high-resolution free-breathing SP-CMR sequence with automated in-line perfusion mapping is presented which accurately detects functionally significant CAD. High-resolution free-breathing stress perfusion cardiovascular magnetic resonance (SP-CMR) with in-line automated quantitative mapping is accurate in the diagnosis of functionally significant coronary artery disease. Diagnostic performance was compared with invasive fractional flow reserve (FFR) with myocardial blood flow (MBF) at hyperaemic stress and myocardial perfusion reserve (MPR) reduced in patients with inducible ischaemia. CTO, chronic total occlusion; AUC, area under the curve.

24 January 2025 in Pediatric Radiology
Verified
Journal Article
Open access
PDF file
AUAlena Uus
Alena Uus
SSSara Neves Silva
Sara Neves Silva
JVJordina Aviles Verdera
Jordina Aviles Verdera
KPKelly Payette
Kelly Payette
MHMegan Hall
Megan Hall
JHJana Hutter
Jana Hutter
Background: Motion correction methods based on slice-to-volume registration (SVR) for fetal magnetic resonance imaging (MRI) allow reconstruction of three-dimensional (3-D) isotropic images of the fetal brain and body. However, all existing SVR methods are confined to research settings, which limits clinical integration. Furthermore, there have been no reported SVR solutions for low-field 0.55-T MRI. Objective: Integration of automated SVR motion correction methods directly into fetal MRI scanning process via the Gadgetron framework to enable automated T2-weighted (T2W) 3-D fetal brain and body reconstruction in the low-field 0.55-T MRI scanner within the duration of the scan. Materials and methods: A deep learning fully automated pipeline was developed for T2W 3-D rigid and deformable (D/SVR) reconstruction of the fetal brain and body of 0.55-T T2W datasets. Next, it was integrated into 0.55-T low-field MRI scanner environment via a Gadgetron workflow that enables launching of the reconstruction process directly during scanning in real-time. Results: During prospective testing on 12 cases (22–40 weeks gestational age), the fetal brain and body reconstructions were available on average 6:42 ± 3:13 min after the acquisition of the final stack and could be assessed and archived on the scanner console during the ongoing fetal MRI scan. The output image data quality was rated as good to acceptable for interpretation. The retrospective testing of the pipeline on 83 0.55-T datasets demonstrated stable reconstruction quality for low-field MRI. Conclusion: The proposed pipeline allows scanner-based prospective T2W 3-D motion correction for low-field 0.55-T fetal MRI via direct online integration into the scanner environment. Graphical

3 December 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
RMRonald Mooiweer
Ronald Mooiweer
RNRadhouene Neji
Radhouene Neji
SMSarah McElroy
Sarah McElroy
MNMuhummad Sohaib Nazir
Muhummad Sohaib Nazir
RRReza Razavi
Reza Razavi
SRSébastien Roujol
Sébastien Roujol
Purpose: To develop and evaluate a fast respiratory navigator (fastNAV) for cardiac MR perfusion imaging with subject‐specific prospective slice tracking.Methods: A fastNAV was developed for dynamic contrast‐enhanced cardiac MR perfusion imaging by combining spatially nonselective saturation with slice‐selective tip‐up and slice‐selective excitation pulses. The excitation slice was angulated from the tip‐up slice in the transverse plane to overlap only in the right hemidiaphragm for suppression of signal outside the right hemidiaphragm. A calibration scan was developed to enable the estimation of subject‐specific tracking factors. Perfusion imaging using subject‐specific fastNAV‐based slice tracking was then compared to a conventional sequence (ie, without slice tracking) in 10 patients under free‐breathing conditions. Respiratory motion in perfusion images was quantitatively assessed by measuring the average overlap of the left ventricle across images (avDice, 0:no overlap/1:perfect overlap) and the average displacement of the center of mass of the left ventricle (avCoM). Image quality was subjectively assessed using a 4‐point scoring system (1: poor, 4: excellent).Results: The fastNAV calibration was successfully performed in all subjects (average tracking factor of 0.46 ± 0.13, R = 0.94 ± 0.03). Prospective motion correction using fastNAV led to higher avDice (0.94 ± 0.02 vs. 0.90 ± 0.03, P < .001) and reduced avCoM (4.03 ± 0.84 vs. 5.22 ± 1.22, P < .001). There were no statistically significant differences between the 2 sequences in terms of image quality (both sequences: median = 3 and interquartile range = 3‐4, P = 1).Conclusion: fastNAV enables fast and robust right hemidiaphragm motion tracking in a perfusion sequence. In combination with subject‐specific slice tracking, fastNAV reduces the effect of respiratory motion during free‐breathing cardiac MR perfusion imaging.

28 March 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
SMSarah McElroy
Sarah McElroy
GFGiulio Ferrazzi
Giulio Ferrazzi
MNMuhummad Sohaib Nazir
Muhummad Sohaib Nazir
CECarl Evans
Carl Evans
JFJoana Ferreira
Joana Ferreira
SRSébastien Roujol
Sébastien Roujol
Purpose: To implement and evaluate a simultaneous multi‐slice balanced SSFP (SMS‐bSSFP) perfusion sequence and compressed sensing reconstruction for cardiac MR perfusion imaging with full left ventricular (LV) coverage (nine slices/heartbeat) and high spatial resolution (1.4 × 1.4 mm2) at 1.5T.Methods: A preliminary study was performed to evaluate the performance of blipped controlled aliasing in parallel imaging (CAIPI) and RF‐CAIPI with gradient‐controlled local Larmor adjustment (GC‐LOLA) in the presence of fat. A nine‐slice SMS‐bSSFP sequence using RF‐CAIPI with GC‐LOLA with high spatial resolution (1.4 × 1.4 mm2) and a conventional three‐slice sequence with conventional spatial resolution (1.9 × 1.9 mm2) were then acquired in 10 patients under rest conditions. Qualitative assessment was performed to assess image quality and perceived signal‐to‐noise ratio (SNR) on a 4‐point scale (0: poor image quality/low SNR; 3: excellent image quality/high SNR), and the number of myocardial segments with diagnostic image quality was recorded. Quantitative measurements of myocardial sharpness and upslope index were performed.Results: Fat signal leakage was significantly higher for blipped CAIPI than for RF‐CAIPI with GC‐LOLA (7.9% vs. 1.2%, p = 0.010). All 10 SMS‐bSSFP perfusion datasets resulted in 16/16 diagnostic myocardial segments. There were no significant differences between the SMS and conventional acquisitions in terms of image quality (2.6 ± 0.6 vs. 2.7 ± 0.2, p = 0.8) or perceived SNR (2.8 ± 0.3 vs. 2.7 ± 0.3, p = 0.3). Inter‐reader variability was good for both image quality (ICC = 0.84) and perceived SNR (ICC = 0.70). Myocardial sharpness was improved using the SMS sequence compared to the conventional sequence (0.37 ± 0.08 vs 0.32 ± 0.05, p < 0.001). There was no significant difference between measurements of upslope index for the SMS and conventional sequences (0.11 ± 0.04 vs. 0.11 ± 0.03, p = 0.84).Conclusion: SMS‐bSSFP with multiband factor 3 and compressed sensing reconstruction enables cardiac MR perfusion imaging with three‐fold increased spatial coverage and improved myocardial sharpness compared to a conventional sequence, without compromising perceived SNR, image quality, upslope index or number of diagnostic segments.