This paper proposes an automatic and intelligent stator fault diagnosis system for permanent magnet synchronous generators. The system is based on the use of a feedforward multilayer perception artificial neural network (ANN) performed by the back-propagation training algorithm. From a thorough study and analysis of the behavior of the negative-sequence voltage of the machine under different stator faults and different operating conditions, two new robust indicators of faults are selected as the ANN inputs. The two fault indicators are the phase angle of the negative sequence voltage and the frequency of the machine voltages. After successfully training and testing the ANN with specific and meaningful databases, the ANN behavior is validated by using an experimental database acquired from a real machine. The accurate results provided by the ANN prove the reliability of the proposed system to automatically diagnose different stator faults under variable speed, variable fault current, and variable load conditions overcoming different disturbances, such as the noisy signals and the harmonics in the machine.
31 January 2017 in IEEE Transactions on Industry Applications
This paper proposes an original, simple, and fast permanent magnet synchronous generator model implemented with a new conception on the graphic interface of MATLAB/Simulink environment. The obtained physical model suggests a new way to easily carry out different types of stator faults such as interturns short-circuit faults, phase-to-phase faults, and phase-to-ground faults, as well as simultaneous multifaults. This is handled by connecting the two desired points in the stator on the graphic interface of Simulink exactly as they can be carried out in the experimental tests. This model has the originality to take into account the arrangement of the stator windings of a multipole machine by differentiating between the windings under the same pole-pair and those under different pole-pairs. A comparison between the simulated and the experimental results is done to verify the behavior of the proposed model in both healthy and faulty modes under different operating speeds. The good comparison results lead to validate the correct behavior of the proposed model with a satisfactory accuracy.
16 January 2023 in IEEE Transactions on Industry Applications
In the aim to increase the reliability of the permanent magnet synchronous generator (PMSG), this paper proposes an efficient symmetrical component-based method to detect and accurately diagnose an incipient inter-turn short circuit (ITSC) fault in the PMSG without any confusion with a load unbalance. In fact, the existence of a negative sequence voltage component in the PMSG may be due to ITSC faults or to load unbalance, which creates confusion and affects the accuracy of the fault detection. To address this issue, this paper proposes a novel robust indicator capable of distinguishing without any ambiguity, an ITSC fault from a load unbalance in the machine. Hence, the objective of this paper is to demonstrate the behavior and the effectiveness of the novel indicator able to discriminate between the two operating modes, through original thorough analytical and simulation studies, validated experimentally on a real PMSG.
The negative sequence current can offer an efficient and fast monitoring technique to detect incipient stator fault in induction machines. However, unbalanced supply voltage, inherent machine asymmetry and non ideal sensors can also contribute to the generation of this negative sequence current. Thus, it is rather difficult to extract the negative sequence current caused only by the fault. To improve the accuracy of fault detection, this paper proposes an efficient method based on the use of experimental techniques to identify and separate the negative sequence current due to the inherent asymmetry in the machine and the non-calibration of the sensors in order to extract the negative sequence current caused only by the fault. The efficiency of the proposed method is demonstrated by the use of experimental data's coming from 1.1 kW motor supplied by a balanced voltage.