Xuanlin Long

Xuanlin Long

Auto-generated profile, based on publicly available information

Xuanlin Long

State Key Laboratory of Disaster Prevention and Reduction for Power Grid, School of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2025 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
XLXuanlin Long
Xuanlin Long
KYKun Yu
Kun Yu
XZXiangjun Zeng
Xiangjun Zeng
YNYuzhou Ning
Yuzhou Ning
JZJupeng Zeng
Jupeng Zeng
WWWei Wang
Wei Wang
Existing protection methods for DC distribution networks suffer from limitations such as low transition resistance tolerance, noise susceptibility, and inadequate speed. To overcome these challenges, this paper first establishes a bipolar short-circuit fault model that considers multi-converter interactions. Based on this model, we reveal the intrinsic relationship between fault current energy distribution and fault conditions, and propose a novel protection criterion utilizing the Energy Peak-to-Average Ratio (EPAR) of the fault current. By converting the time-domain waveform characteristics of the fault current into energy distribution features, the method effectively characterizes the influence of transition resistance on fault characteristics, enabling rapid and reliable identification of high-impedance bipolar short-circuit faults. An adaptive collaborative protection method leveraging the complementary characteristics of EPAR and current variation is developed. By constructing a dual-criterion coordination mechanism integrating current variation and EPAR, this method enables dynamic setting and complementary identification, ensuring full-line rapid protection for internal bipolar faults. Furthermore, the impact of setting value selection on protection reliability and sensitivity was quantitatively analyzed, constraints in the protection setting process were elucidated, and a theoretical basis for applying the proposed method to DC distribution networks with different structures was provided. A 10 kV multi-terminal flexible DC distribution network model incorporating diverse converters is built in PSCAD/EMTDC to validate the proposed method under various fault conditions. Simulation results demonstrate that the method accurately discriminates faults within 1.5 ms after occurrence, achieves transition resistance tolerance up to $100~\Omega $ , and exhibits strong noise immunity.