21 August 2019 in IEEE Transactions on Power Electronics
Impedance-based methods are effective for stability assessment of cascaded systems. However, DC distribution power system (DPS) is becoming increasingly complex, incorporating multi-voltage levels, many DC buses and numerous converters. Consequently, conventional stability criteria, such as Middlebrook criterion and its extensions, may not have the ability to judge stability very succinctly. Thus, more research work related to stability evaluation of DC DPS with multi-voltage levels needs to be carried out. This paper proposes an impedance-based stability assessment methodology. First of all, a unified form of the system is obtained regardless of its structures and operating modes, based on classification of any converter as either a bus voltage controlled converter (BVCC) or a bus current controlled converter (BCCC). Then, according to the two-port small signal model, the equivalent loop gain of the system is derived precisely. It should be noted that intermediate bus converter (IBC) could adopt output current or output voltage control modes, which will have influence on the equivalent loop gain expression. After that, the stability requirement of the system is given by introducing the Nyquist criterion to the equivalent loop gain. Finally, an experimental prototype is established to validate the effectiveness of the proposed criterion.
9 February 2021 in IEEE Transactions on Power Electronics
The stability analysis methods of single-bus dc distribution power systems (DPSs) have been widely studied; however, the multivoltage-level dc DPSs, which have been used in data center, all-electric ship, and so on, its stability analysis methods are rarely reported. The main focus of this article is to study the stability analysis methods, especially the impedance ratio of multivoltage-level dc DPSs. From the point of view of whole system, the two-port small-signal models of multivoltage-level dc DPSs are established and the equivalent loop gains are obtained and used to judge the system stability. On the other hand, the multivoltage-level dc DPSs can be regarded as conventional single-bus dc DPSs at different interfacing locations, and the impedance-ratio type stability criteria are obtained. And it is proved that the two stability analysis methods, namely the system equivalent loop gain and impedance-ratio type stability criterion at different interfacing locations, have the same stability results, which clarifies the stability status by considering different interfacing locations. Finally, the analysis is verified with simulations and hardware-based experiments of a three-converter three-stage dc DPS.
7 February 2022 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Two individually stable converters are well-known preconditions for discussing the stability of a two-stage cascaded system. However, for a multistage cascaded system, the relationship between its stability and subsystem stability is barely reported due to the lack of modeling method and in-depth stability analysis. In this article, the above problems are solved. First, the generic two-port small-signal model of the multistage cascaded dc–dc converters is established, and its equivalent minor loop gain is calculated, which can be used to assess system stability. On this basis, the stability condition of the triple-stage cascaded dc system is further deduced and compared with its two subsystems. Then, an interesting conclusion is obtained that the whole system may be stable even if some of its subsystems cannot operate stably individually. Besides, according to the deduced stability condition, some existing stability criteria of the triple-stage cascaded dc system are explained uniformly, and a bus equivalent impedance criterion (BEIC) is proposed. Finally, the case study and experiments are carried out to verify the correctness of the theoretical analysis.
2 July 2024 in IEEE Transactions on Sustainable Energy
To achieve the 2050 global climate target, offshore wind will increase to meet the growing demand of direct and indirect electrification (e.g. green hydrogen production for the hard-to-abate sector). To keep up with the rapid increase of offshore wind generation, the energy balancing challenges due to the intermittency nature of wind and the network congestion/capacity challenges resulting from structural network capacity planning latency are to be addressed with system integration technology. In this paper, it is proposed that the hydrogen electrolysis plant be co-located with the wind farm, where the power consumption is controlled to track the wind generation profile accurately to cancel the intermittency of wind generation, reduce the required grid connection capacity, and thereby avoid expensive grid expansion. However, this power tracking controller introduces a cross-plant feedback path from the wind farm to the hydrogen plant, posing challenges for partitioning the power tracking loop completely for stability analysis, which also makes it difficult to make a good trade-off between the tracking performance and stability margins. To address this issue, this paper proposes an equivalent transformation to eliminate the cross-plant feedback path. Then, the criteria for choosing the optimal partition method are proposed and examined for different types of partition methods, which are mathematically proven to be equivalent in terms of stability conditions but provide different insights. An optimal partition method is then proposed in this paper, which not only provides clear insight on the ideal and non-ideal power tracking performances but also can also identify the stability issues of different minor loops individually. Finally, the proposed optimal partition method and its valuable insights into power tracking performance and stability analysis are validated through time-domain simulations of a 180 MW integrated wind-to-hydrogen plant with a realistic complexity.
20 June 2025 in IEEE Transactions on Industrial Electronics
Virtual oscillator control (VOC) is a time-domain strategy for regulating grid-forming converters by emulating the dynamics of nonlinear oscillator circuits. Among the three commonly used VOC types—Van der Pol, dead-zone, and Andronov-Hopf (AH) oscillators—only the AH oscillator generates harmonic-free waveforms, whereas the Van der Pol and dead-zone oscillators introduce harmonic content. However, the dead-zone oscillator uniquely features a bounded nonlinear gain, which is essential for ensuring global asymptotic large-signal stability in the VOC-based converter-grid system under large grid disturbances. To address existing design limitations, a two-dimensional dead-zone (TDDZ) oscillator is proposed for the first time, combining harmonic-free oscillations with a bounded nonlinear gain. The harmonic-free attribute is achieved by coupling 2-D states to define the nonlinear forcing function. Meanwhile, the nonlinear gain is retained as bounded by setting the boundaries of nonlinear functions, accounting for both the inherent nonlinearity of the damping function and the nonlinearity introduced by the power regulation loop. Perturbation theory is utilized to demonstrate the harmonic-free attribute, and the small-gain theorem is applied to assess the global asymptotic large-signal stability of the TDDZ-based converter-grid system. The effectiveness of the proposed TDDZ oscillator is validated through simulation and experimental results.
5 February 2025 in IEEE Transactions on Power Electronics
The existing immittance-based stability analysis approaches for dc microgrids rarely account for the line network, and they are always troubled by the non-minimum phase issues. In this article, we introduce a novel method for stability analysis based on the determinant of the constructed immittance matrix. Since the determinant's right-half-plane poles are explicitly proven absent, it is only necessary to ascertain the net number of times that the phase trajectory crosses the ±180° line in system stability analysis. Subsequently, based on the immittance matrix decomposition and sensitivity calculation, a participation analysis method is further presented to identify the critical converter that dominates system instability. Finally, the simulation case of a 750 V 30 kW dc microgrid and the experiment case of a 24 V 180 W dc microgrid are established to validate these methods.