Paul Diaz

Paul Diaz

Auto-generated profile, based on publicly available information

Paul Diaz


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016
Verified
Report
Closed access
PDF file
LSLiam N. Schenk
Liam N. Schenk
CAChauncey W. Anderson
Chauncey W. Anderson
PDPaul Diaz
Paul Diaz
MSMarc A. Stewart
Marc A. Stewart
Suspended-sediment and total phosphorus loads were computed for two sites in the Upper Klamath Basin on the Wood and Williamson Rivers, the two main tributaries to Upper Klamath Lake. High temporal resolution turbidity and acoustic backscatter data were used to develop surrogate regression models to compute instantaneous concentrations and loads on these rivers. Regression models for the Williamson River site showed strong correlations of turbidity with total phosphorus and suspended-sediment concentrations (adjusted coefficients of determination [Adj R2]=0.73 and 0.95, respectively). Regression models for the Wood River site had relatively poor, although statistically significant, relations of turbidity with total phosphorus, and turbidity and acoustic backscatter with suspended sediment concentration, with high prediction uncertainty. Total phosphorus loads for the partial 2014 water year (excluding October and November 2013) were 39 and 28 metric tons for the Williamson and Wood Rivers, respectively. These values are within the low range of phosphorus loads computed...

1 January 2008 in Scientific Investigations Report
Verified
Other
Closed access
MSMichael R. Stevens
Michael R. Stevens
PDPaul Diaz
Paul Diaz
DSDennis E. Smits
Dennis E. Smits

1 January 2008 in Data Series
Verified
Other
Closed access
NSNorman E. Spahr
Norman E. Spahr
DHDavid M. Hartle
David M. Hartle
PDPaul Diaz
Paul Diaz

1 January 2026
Verified
Report
Open access
PDF file
JGJoel Groten
Joel Groten
CRClaire E. Rose
Claire E. Rose
WOWayne O'NEal
Wayne O'NEal
LSLane B. Simmons
Lane B. Simmons
TSTimothy D. Straub
Timothy D. Straub
PDPaul Diaz
Paul Diaz
Accurate collection of fluvial suspended‑sediment and water‑quality samples is essential for understanding transport processes, evaluating river health, quantifying loads, and supporting regulatory and management decisions. Since 1939, the Federal Interagency Sedimentation Project (FISP) has led the development and standardization of sediment‑sampling equipment and methods across Federal agencies. Although substantial advancements have been made, the most recent point‑integrating sampler developed in 2006 has notable limitations, including insufficient sample volume for low‑concentration analyses and a mechanically complex pressure‑equalization system required for a rigid-bottle sample container. To address these limitations, FISP collaborated with Carnet Technology to design, fabricate, and test a new collapsible‑bag sampler capable of collecting larger sample volumes and operating as either a point‑integrating or depth‑integrating sampler. The resulting sampler, the US XPD‑24‑200, was evaluated through controlled tow‑tank tests and field testing in a lake environment.Results indicate that the US XPD‑24‑200 can collect a 5.5-fold increase in maximum sample volume than a pre-existing point sampler developed in 2006. The US XPD‑24‑200 performs isokinetically within the expected intake efficiency (IE) range under most conditions. Approximately 73 percent of IEs fell within the target range of 0.9–1.1. A mild bias was observed with IE values outside this range that were predominantly lower than 0.9 and occurred most frequently at the lower test velocities, whereas only 2 percent of IEs exceeded 1.1, primarily at the highest velocities tested. Tow‑tank tests produced tightly clustered IE values with low variability, demonstrating stable performance under controlled conditions. Lake towing tests exhibited more variability, reflecting natural environmental influences such as turbulence, temperature gradients, and unsteady inflow. Collectively, the results demonstrate that the US XPD‑24‑200 provides reliable IEs comparable to existing samplers while offering increased sample volume, reduced mechanical complexity, and enhanced operational flexibility.