Pietro Bernardo Dall'AGlio

Pietro Bernardo Dall'AGlio

Auto-generated profile, based on publicly available information

Pietro Bernardo Dall'AGlio

Department of Cardiology and Medical Intensive Care, St. Josef Hospital Freiburg , Freiburg , Germany

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ACAlberto Cipriani
Alberto Cipriani
GDGianpiero D'Amico
Gianpiero D'Amico
GBGiulia Brunetti
Giulia Brunetti
GVGiovanni Maria Vescovo
Giovanni Maria Vescovo
FDFilippo Donato
Filippo Donato
Alessandro ZorziAlessandro Zorzi
Alessandro Zorzi
Primary ventricular fibrillation (PVF) may occur in the early phase of ST-elevation myocardial infarction (STEMI) prior to primary percutaneous coronary intervention (PCI). Multiple electrocardiographic STEMI patterns are associated with PVF and short-term mortality including the tombstone, Lambda, and triangular QRS-ST-T waveform (TW). We aimed to compare the predictive value of different electrocardiographic STEMI patterns for PVF and 30-day mortality. We included a consecutive cohort of 407 STEMI patients (75% males, median age 66 years) presenting within 12 h of symptoms onset. At first medical contact, 14 (3%) showed the TW or Lambda ECG patterns, which were combined in a single group (TW-Lambda pattern) characterized by giant R-wave and downsloping ST-segment. PVF prior to primary PCI occurred in 39 (10%) patients, significantly more often in patients with the TW-Lambda pattern than those without (50% vs. 8%, p < 0.001). For the multivariable analysis, Killip class ≥3 (OR 6.19, 95% CI 2.37–16.1, p < 0.001) and TW-Lambda pattern (OR 9.64, 95% CI 2.99–31.0, p < 0.001) remained as independent predictors of PVF. Thirty-day mortality was also higher in patients with the TW-Lambda pattern than in those without (43% vs. 6%, p < 0.001). However, only LVEF (OR 0.86, 95% CI 0.82–0.90, p < 0.001) and PVF (OR 4.61, 95% CI 1.49–14.3, p = 0.042) remained independent predictors of mortality. A mediation analysis showed that the effect of TW-Lambda pattern on mortality was mediated mainly via the reduced LVEF. In conclusion, among patients presenting with STEMI, the electrocardiographic TW-Lambda pattern was associated with both PVF before PCI and 30-day mortality. Therefore, this ECG pattern may be useful for early risk stratification of STEMI.

21 December 2022 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
FMFederico Migliore
Federico Migliore
RPRaimondo Pittorru
Raimondo Pittorru
PDPietro Bernardo Dall'AGlio
Pietro Bernardo Dall'AGlio
MLManuel De Lazzari
Manuel De Lazzari
GRGiovanni Rovaris
Giovanni Rovaris
PMPatrizio Mazzone
Patrizio Mazzone

2 July 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
FMFederico Migliore
Federico Migliore
RPRaimondo Pittorru
Raimondo Pittorru
MLManuel De Lazzari
Manuel De Lazzari
PDPietro Bernardo Dall’aGlio
Pietro Bernardo Dall’aGlio
ACAntonella Cecchetto
Antonella Cecchetto
Giacomo GerosaGiacomo Gerosa
Giacomo Gerosa
Transvenous lead extraction (TLE) is potentially complicated by significant tricuspid valve regurgitation increase (TRI). However, there are limited data on the effect of the bidirectional rotational mechanical sheaths on significant TRI. The aim of the present study was to investigate the rate of significant changes in tricuspid regurgitation (TR) severity following mechanical rotational TLE and their outcomes. In 158 patients (mean age 66 ± 16.9 years) undergoing mechanical rotational TLE, acute changes in TR severity were assessed by echocardiography evaluation. A significant acute TRI was defined as an increase of at least one grade with a post-extraction severity at least moderate. A total of 290 leads were extracted (mean implant duration, 93 ± 65 months). Significant TRI was noted in 5.7% of patients, and it was linked to tricuspid valve damage, TLE infection indication, and longer lead implant duration. Univariate predictors of significant TRI included implant duration of all leads [odds ratio (OR) 1.01; 95% confidence interval (CI) 1.003–1.018; P = 0.001] and right ventricular leads (OR 1.01; 95% CI 1.004–1.017; P = 0.002). Severe increase of TR following TLE was an independent predictor of mortality [hazard ratio (HR) 5.20; 95% CI 1.44–18.73; P = 0.012 ] along with severe systolic dysfunction (HR 2.37; 95% CI 1.01–5.20; P = 0.032), and systemic infection (HR 2.28; 95% CI 1.06–4.89; P = 0.035). Significant TRI was detected in 5.7% of patients following transvenous rotational mechanical lead extraction. The duration of lead implantation emerged as the sole predictor of significant TRI. Physicians engaged in TLE should exercise greater vigilance for this potential complication.

7 April 2023 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Open access
FMFederico Migliore
Federico Migliore
RPRaimondo Pittorru
Raimondo Pittorru
PDPietro Bernardo Dall'AGlio
Pietro Bernardo Dall'AGlio
MLManuel De Lazzari
Manuel De Lazzari
PFPasquale Valerio Falzone
Pasquale Valerio Falzone
DCDomenico Carretta
Domenico Carretta
Background: Outcomes of transvenous lead extraction (TLE) are well reported in the general population, However, data on safety, efficacy of TLE in octogenarians with a long lead dwell time, using powered extraction tools are limited. The aim of this multicenter study was to evaluate the safety, effectiveness of TLE in octogenarians using the bidirectional rotational mechanical sheaths and mid‐term outcome after TLE.Methods: The study population comprised 83 patients (78.3% male; mean age 85 ± 3 years; [range 80–94 years]) with 181 target leads. All the leads (mean implant duration 112 ± 77 months [range 12–377]) were extracted exclusively using the Evolution RL sheaths (Cook Medical, Bloomington, IN, USA).Results: The main indication for TLE was infection in 84.3% of cases. Complete procedural success rate, clinical success rate, per lead were 93.9% and 98.3%, respectively. Failure of lead extraction was seen in 1.7% of leads. The additional use of a snare was required in 8.4% of patients. Major complications occurred in one patient (1.2%). Thirty‐day mortality after TLE was 6%. During a mean time follow‐up of 22 ± 21 months, 24 patients (29%) died. No procedure‐related mortality occurred. Predictors of mortality included ischemic cardiomyopathy (HR 4.35; 95% CI 1.87–10.13; p = .001), left ventricularejection fraction ≤35% (HR 7.89; 95% CI 3.20–19.48; p < .001), and TLE for systemic infection (HR 4.24; 95% CI 1.69–10.66; p = .002).Conclusions: At experienced centers bidirectional rotational mechanical sheaths combined with different mechanical tools and femoral approach allowreasonable success and safety in octogenarian with long lead dwell time. Patient's age should not influence the decision to extract or not the leads, although the 30‐day and mid‐term mortality are significant, especially in the present of specific comorbidities.

9 December 2022 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Open access
LTLuca Trolese
Luca Trolese
PDPietro Bernardo Dall'AGlio
Pietro Bernardo Dall'AGlio
JSJohannes Steinfurt
Johannes Steinfurt
AGAlexander Gressler
Alexander Gressler
TFThomas Faber
Thomas Faber
SGStudy Group
Study Group
Introduction: Defibrillation testing (DFT) is recommended during subcutaneous implantable cardioverter‐defibrillator (S‐ICD) implantation. Previous studies analyzing the potential interference of propofol with defibrillation threshold are inconsistent. The purpose of this study was to analyze whether propofol affects DFT post S‐ICD placement.Methods: All patients with S‐ICD implantation between 01/2017 and 11/2020 at the University Heart Center Freiburg were retrospectively analyzed. Two groups were generated depending on the success of the first shock during DFT. Implantation characteristics and dose of anesthetics were analyzed.Results: In 12 of the included 80 (15%) patients, first shock during DFT failed. The absolute dose of propofol was significantly higher in patients with first shock failure (median 653 mg [IQR 503–855]) compared to patients with first shock termination (376 mg [200–600]; p = 0.027). Doses of opioids and midazolam as well as type of anesthesia did not differ between the groups. A multivariable binary logistic regression analysis confirmed an independent association of first shock termination and propofol dose (per 100 mg: OR 0.73 (95% CI: 0.56–0.95); p = 0.021).Conclusion: There is an independent association of propofol dose and first shock failure in routine S‐ICD defibrillation testing.