Juliano de Pelegrini Lopes

Juliano de Pelegrini Lopes

Auto-generated profile, based on publicly available information

Juliano de Pelegrini Lopes

Federal University of Technology - Paraná (UTFPR), Pato Branco, Paraná, Brazil

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018
Verified
Conference Paper
Closed access
MFMatheus K. Ferst
Matheus K. Ferst
HFHugo F. M. de Figueiredo
Hugo F. M. de Figueiredo
GDGustavo Denardin
Gustavo Denardin
JLJuliano Lopes
Juliano Lopes
Industrial Control Systems (ICS) and Supervisory Control systems and Data Acquisition (SCADA) networks implement industrial communication protocols to enable their operations. Unfortunately, wide used protocols, such as Modbus and DNP3, lack basic security mechanisms that lead to multiple vulnerabilities. The exploitation of such flaws may greatly impact companies and the general population, especially for attacks targeting critical infrastructural assets such as power plants, water distribution, and railway transportation systems. Such problem gets worse in the context of photovoltaic Distributed Energy Resources (DER), where devices are commonly located in customers facilities, making difficult to enforce appropriate security policies. This paper addresses the security problems of the Modbus protocol, proposing a new secure version based on the Transport Layer Security protocol. Experimental results shows that the proposed solution achieves request/response times way below the 16.67 ms period of the power grid 60 Hz cycle, revealing a negligible impact in power grids applications.

1 November 2015
Verified
Conference Paper
Closed access
FGFlavio Lori Grando
Flavio Lori Grando
Gustavo DenardinGustavo Denardin
Gustavo Denardin
MMMiguel Moreto
Miguel Moreto
JLJuliano De Pelegrini Lopes
Juliano De Pelegrini Lopes
This paper present the developments of a low-cost Phasor Measurement Unit (PMU) for smart grid monitoring. This PMU is being developed for large-scale use in the distribution system allowing to monitor local and transmission level events. The device provides magnitude, angle and frequency data of the AC voltage in a synchronized way, between any point in the electrical system, even geographically distant. The instrumentation system is designed to connect in low voltage distribution network. For the acquisition and processing system is employed a general purpose hardware with architecture that allows high precision data and processing performance. The used phasor estimation method is Discrete Fourier Transform with fixed window and adaptive sample rate for minimizing spectral leakage effect. The results of this paper include the validation of instrumentation and acquisition system for steady state conditions.

1 June 2010
Verified
Conference Paper
Closed access
MSM. F. da Silva
M. F. da Silva
JLJ. de P. Lopes
J. de P. Lopes
NCN. B. Chagas
N. B. Chagas
ASA. R. Seidel
A. R. Seidel
MCM. A. Dalla Costa
M. A. Dalla Costa
RPR. N. Do Prado
R. N. Do Prado
The use of the fluorescent lamps without electrodes (electrodeless) has been increasing, because of their features such as lifetime and lumen efficiency, when compared to conventional fluorescent and high pressure sodium (HPS) lamps. This paper presents a luminous flux variation strategy using a Single Ended Primary Inductance Converter (SEPIC), which also provides high power factor correction, to feed electrodeless fluorescent lamps. Since the load is variable a digital compensation is used to meet the control of the specified output voltage in the project, once the dimming characteristic is achieved by varying the SEPIC output voltage. A microcontroller is used in order to allow a suitable control for the converter since it presents features that make possible to obtain dimming capability. The lumens information can be done through wireless system.

1 April 2017
Verified
Conference Paper
Closed access
CGCassio Gobbato
Cassio Gobbato
Gustavo DenardinGustavo Denardin
Gustavo Denardin
JLJuliano De Pelegrini Lopes
Juliano De Pelegrini Lopes
This paper presents a comparative study between different types of stage connections of DC-DC converters used in street lighting systems based on LEDs. One of the connections is based on the technique known as Reduced Redundant Power Processing (R2P2) and the other is the traditional series connection. The SEPIC and Buck-Boost converters were implemented in the power factor correction and control stages, respectively. Both of converters operate in discontinuous conduction mode. Through the obtained experimental results in open loop one can verify the performance of each connection configuration. A discussion is made about the advantages and disadvantages of each connection in order to assist the designer when choosing which connection to use depending on design requirements.

9 March 2017
Verified
Conference Paper
Closed access
CGCassio Gobbato
Cassio Gobbato
SKSamuel Valerio Kohler
Samuel Valerio Kohler
ISIthalo Hespanhol de Souza
Ithalo Hespanhol de Souza
Gustavo DenardinGustavo Denardin
Gustavo Denardin
JLJuliano de Pelegrini Lopes
Juliano de Pelegrini Lopes
This paper presents a modular topology for the design of a luminaire for street lighting based on LEDs. Each module consists of a driver which is composed by two integrated DC-DC converters. The first one is a sepic converter which is responsible for correcting the power factor, and the second is a buck converter which is responsible for the power control delivered to the load. Both converters are operating in discontinuous conduction mode (DCM). In order to make the system more robust against failure, the topology proposes that each driver supply an independent set of power LED. Thus, in case of failure of one or more individual drivers, the system is not compromised completely. The design of the electronic drivers are developed. Experimental results are performed for the proposed lighting system in order to show the feasibility of the idea.

1 October 2012
Verified
Conference Paper
Closed access
JLJ. de P. Lopes
J. de P. Lopes
MMM. F. Menke
M. F. Menke
Fabio BisognoFabio Bisogno
Fabio Bisogno
RPR. N. Do Prado
R. N. Do Prado
Javier RibasJavier Ribas
Javier Ribas
ASA. R. Seidel
A. R. Seidel
This paper presents a self-oscillating electronic ballast to operate T5 HO fluorescent lamps with power ratings of 24 W, 39 W and 49 W. The proposed circuit detects the lamp type by measuring the lamp voltage through a control circuit which changes the power factor correction circuit duty cycle to adequate the output power. Experimental results are shown to demonstrate the feasibility of the proposed solution.