Flavio Lori Grando

Flavio Lori Grando

Auto-generated profile, based on publicly available information

Flavio Lori Grando

Gnarus Institute, Brasil

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2021 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
FGFlavio Lori Grando
Flavio Lori Grando
André Eugênio LazzarettiAndré Eugênio Lazzaretti
André Eugênio Lazzaretti
MMMiguel Moreto
Miguel Moreto
The use of synchrophasor data is recurrent in electrical power systems and has an increasing demand in distribution networks. The quality of this data can directly influence later stages related to decision-making. In this sense, this work presents the impact analysis of synchrophasor data quality on the event classification in distribution networks. We propose a controlled environment, simulating 37 200 events and including errors in the data with different levels, distributions, and biases, enabling evaluations according to the data’s precision and accuracy. Additionally, we present 2 160 classification results involving six machine learning methods, three different groups with 4, 8, and 62 events (classes) per group, and several characteristics of phasor errors. In addition to comparative analyzes, the research scope makes it possible to map the influence of multiple sources of errors, disclosing the data quality relevance and how it affects the event recognition in the distribution systems – a subject underexplored in the recent literature.

12 April 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
FGFlavio Lori Grando
Flavio Lori Grando
André Eugênio LazzarettiAndré Eugênio Lazzaretti
André Eugênio Lazzaretti
Gustavo DenardinGustavo Denardin
Gustavo Denardin
MMMiguel Moreto
Miguel Moreto
HNHugo Vieira Neto
Hugo Vieira Neto
The development of platforms and methods for test and calibration of phasor measurement units (PMUs) has drawn attention from the power systems community, especially due to the wide range of specific tests that must be performed. Aiming at reducing labor-intensive processes and the complexity of such tests, this paper presents an automated platform for test, calibration, and performance assessment of PMUs following the IEEE Std C37.118.1. The platform is composed of signal-generation hardware and software running on a personal computer. The test signals are synthesized in software, allowing different waveform configurations for automated testing. Also, the software receives information from the PMU under test and compares it to reference data, displaying results and statistics in real time. Because most of the functions of the system are performed in software, easy inclusion of additional tests or migration to other signal-generation hardware platforms is possible. The resulting test system allows tracing the behavior of the hardware and corresponding embedded software used in the PMU architecture under test through thousands of measurements collected in just a few minutes. The simple and versatile low-cost system presented in this paper enables accurate, flexible, and versatile automated testing of PMU devices with real-time visualization of results.

14 February 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
PSPedro V. H. Seger
Pedro V. H. Seger
FGFlavio L. Grando
Flavio L. Grando
André Eugênio LazzarettiAndré Eugênio Lazzaretti
André Eugênio Lazzaretti
MMMiguel Moreto
Miguel Moreto
Gustavo DenardinGustavo Denardin
Gustavo Denardin
CPCristian R. Pastro
Cristian R. Pastro
This article presents the latest developments of a phasor measurement unit (PMU), hereby named freePMU , aimed at a large-scale deployment in low-voltage distribution networks. The defining characteristics of this device are its low cost, general-purpose hardware architecture, and software now made open source. This PMU has already been shown to reliably measure voltage, angle, and frequency events in a real distribution network while complying with the IEEE class P PMU standards. In this work, several new results are shown, such as harmonic estimation, detection of different consumer load patterns, and load variations on a distribution feeder. Moreover, its hardware and software architectures are now made public, contributing to the project goal of a cheap and mass-deployable PMU. All of those results attest to the original contributions of this work, compared to other PMUs focused on distribution systems.

1 January 2021 in Brazilian Archives of Biology and Technology
Verified
Journal Article
Open access
APAndré Pedretti
André Pedretti
MSMariana Santini
Mariana Santini
JSJosnei Scolimoski
Josnei Scolimoski
MQMauro Henrique Brito de Queiroz
Mauro Henrique Brito de Queiroz
FTFrank Toshioka
Frank Toshioka
MRMilton Pires Ramos
Milton Pires Ramos

3 January 2021 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
GCGabriel U. Carvalho
Gabriel U. Carvalho
Gustavo DenardinGustavo Denardin
Gustavo Denardin
Rafael CardosoRafael Cardoso
Rafael Cardoso
FGFlavio L. Grando
Flavio L. Grando
Most of the proposed algorithms for synchrophasor estimation are based on the Discrete Fourier Transform (DFT). However, this technique has well‐known limitations, such as the leakage effect. Alternatively, this paper presents a positive‐sequence synchrophasor measurement algorithm based on a Synchronous Reference Frame Phase‐Locked Loop (SRF‐PLL). The algorithm is modular and consists of four stages. The first one is the abc‐dq transform that, with the aid of the second stage, a Finite Impulse Response (FIR) provides the positive‐sequence of the grid voltages. The filter also helps to improve the signal‐to‐noise ratio. This filter class was chosen due to its characteristic of linear phase and constant group delay to avoid unwanted phase distortions at the measurements. The third stage is an SRF‐PLL based on a PID controller that estimates the amplitude and phase of the grid voltage's positive‐sequence component and the grid frequency. By assessing the dynamic condition tests, it was observed that the PLL could not comply with all the IEEE standard requirements. Therefore, a fourth stage was included to calculate the frequency, and Rate of Change of Frequency (ROCOF) based on the estimated positive‐sequence phase. Experimental results obtained with a test platform shown that the proposed algorithm complies with all IEEE C37.118.1‐2011 and C37.118.1a‐2014 standard requirements.

1 November 2015
Verified
Conference Paper
Closed access
FGFlavio Lori Grando
Flavio Lori Grando
Gustavo DenardinGustavo Denardin
Gustavo Denardin
MMMiguel Moreto
Miguel Moreto
JLJuliano De Pelegrini Lopes
Juliano De Pelegrini Lopes
This paper present the developments of a low-cost Phasor Measurement Unit (PMU) for smart grid monitoring. This PMU is being developed for large-scale use in the distribution system allowing to monitor local and transmission level events. The device provides magnitude, angle and frequency data of the AC voltage in a synchronized way, between any point in the electrical system, even geographically distant. The instrumentation system is designed to connect in low voltage distribution network. For the acquisition and processing system is employed a general purpose hardware with architecture that allows high precision data and processing performance. The used phasor estimation method is Discrete Fourier Transform with fixed window and adaptive sample rate for minimizing spectral leakage effect. The results of this paper include the validation of instrumentation and acquisition system for steady state conditions.