Engineered microstructures that mimic in vivo tissues have demonstrated great potential for applications in regenerative medicine, drug screening, and cell behavior exploration. However, current methods for engineering microstructures that mimic the multi-extracellular matrix and multicellular features of natural tissues to realize tissue-mimicking microstructures in vitro remain insufficient. Here, we propose a versatile method for constructing tissue-mimicking heterogeneous microstructures by orderly integration of macroscopic hydrogel exchange, microscopic cell manipulation, and encapsulation modulation. First, various cell-laden hydrogel droplets are manipulated at the millimeter scale using electrowetting on dielectric to achieve efficient hydrogel exchange. Second, the cells are manipulated at the micrometer scale using dielectrophoresis to adjust their density and arrangement within the hydrogel droplets. Third, the photopolymerization of these hydrogel droplets is triggered in designated regions by dynamically modulating the shape and position of the excitation ultraviolet beam. Thus, heterogeneous microstructures with different extracellular matrix geometries and components were constructed, including specific cell densities and patterns. The resulting heterogeneous microstructure supported long-term culture of hepatocytes and fibroblasts with high cell viability (over 90%). Moreover, the density and distribution of the 2 cell types had significant effects on the cell proliferation and urea secretion. We propose that our method can lead to the construction of additional biomimetic heterogeneous microstructures with unprecedented potential for use in future tissue engineering applications.
Digital microfluidic chips (DMCs) have shown huge potential for biochemical analysis applications due to their excellent droplet manipulation capabilities. The driving force is a critical factor for characterizing and optimizing the performance of droplet manipulation. Conducting numerical analysis of the driving force is essential for DMC design, as it helps optimize the structural parameters. Despite advances in numerical analysis, evaluating driving forces in partially filled electrodes remains challenging. Here, we propose a versatile electrodynamics simulation model designed to analyze the driving forces of partially filled electrodes to optimize the structural parameters of DMCs. This model utilizes finite element analysis to determine the voltage distribution within the DMC and calculates the driving force acting on the droplets using the principles of virtual work. Using this electrodynamics simulation model, we evaluated the effects of various structural parameters, including the dielectric constant and thickness of the dielectric layer, the dielectric constant and conductivity of the droplet, and substrate spacing, on the droplet driving force. This evaluation helps to optimize the structural parameters and enhances the droplet manipulation of DMCs. Measurements of droplet acceleration demonstrated that the droplet acceleration on the partially filled electrode aligns with the simulated driving force trend, which verified the effectiveness of the proposed electrodynamics simulation model. We anticipate that the electrodynamics simulation model is capable of evaluating the driving force in partially filled electrodes within complex DMCs, offering unprecedented possibilities for future structural designs of DMCs.
Digital microfluidic chips (DMCs) have shown the ability to flexibly manipulate droplets and particles, which is meaningful for biomedical applications in drug screening and clinical diagnostics. As a critical component of DMCs, the dielectric layer, with its key physical parameters (permittivity and thickness), directly determines the voltage distribution, thereby significantly affecting the manipulation performance. To optimize manipulation performance, simulation studies on dielectric layer parameters are essential during the DMC design. Existing simulation methods can evaluate the effect of dielectric layer parameters on droplet manipulation but encounter inherent challenges when analyzing the manipulation of particles within droplets. Here, we propose a versatile numerical analysis approach that can simultaneously analyze the effect of dielectric layer parameters on both droplet and particle manipulation, thereby optimizing the dielectric layer parameters to enhance the DMC manipulation performance. Initially, the voltage distributions corresponding to different sets of dielectric layer parameters are solved using electromagnetic field theory. Subsequently, the voltage distribution data are used to calculate the droplet and particle driving forces based on the principle of virtual work. Finally, by comparing the driving forces across different sets of dielectric layer parameters, the optimal dielectric layer parameters are determined to enhance the DMC manipulation performance. Experimental results demonstrate that the droplet and particle accelerations align with the simulated driving force trends, thereby validating our numerical analysis method. We anticipate that our method will be able to provide theoretical guidance for the optimization of dielectric layer parameters to obtain a desirable manipulation performance in more complex DMC designs.