Kevin Englehart

Kevin Englehart

Auto-generated profile, based on publicly available information

Kevin Englehart

Institute of Biomedical Engineering, University of New Brunswick, Fredericton, Canada

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2003 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
KEK. Englehart
K. Englehart
BHB. Hudgins
B. Hudgins
This paper represents an ongoing investigation of dexterous and natural control of upper extremity prostheses using the myoelectric signal (MES). The scheme described within uses pattern recognition to process four channels of MES, with the task of discriminating multiple classes of limb movement. The method does not require segmentation of the MES data, allowing a continuous stream of class decisions to be delivered to a prosthetic device. It is shown in this paper that, by exploiting the processing power inherent in current computing systems, substantial gains in classifier accuracy and response time are possible. Other important characteristics for prosthetic control systems are met as well. Due to the fact that the classifier learns the muscle activation patterns for each desired class for each individual, a natural control actuation results. The continuous decision stream allows complex sequences of manipulation involving multiple joints to be performed without interruption. Finally, minimal storage capacity is required, which is an important factor in embedded control systems.

1 March 2001 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
KEK. Englehart
K. Englehart
BHB. Hudgin
B. Hudgin
PPP.A. Parker
P.A. Parker
This work represents an ongoing investigation of dexterous and natural control of powered upper limbs using the myoelectric signal. When approached as a pattern recognition problem, the success of a myoelectric control scheme depends largely on the classification accuracy. A novel approach is described that demonstrates greater accuracy than in previous work. Fundamental to the success of this method is the use of a wavelet-based feature set, reduced in dimension by principal components analysis. Further, it is shown that four channels of myoelectric data greatly improve the classification accuracy, as compared to one or two channels. It is demonstrated that exceptionally accurate performance is possible using the steady-state myoelectric signal. Exploiting these successes, a robust online classifier is constructed, which produces class decisions on a continuous stream of data. Although in its preliminary stages of development, this scheme promises a more natural and efficient means of myoelectric control than one based on discrete, transient bursts of activity.

1 July 1999 in Medical Engineering & Physics
Verified
Journal Article
Closed access
KEK Englehart
K Englehart
BHB Hudgins
B Hudgins
PPP.A Parker
P.A Parker
MSM Stevenson
M Stevenson
An accurate and computationally efficient means of classifying surface myoelectric signal patterns has been the subject of considerable research effort in recent years. Effective feature extraction is crucial to reliable classification and, in the quest to improve the accuracy of transient myoelectric signal pattern classification, an ensemble of time-frequency based representations are proposed. It is shown that feature sets based upon the short-time Fourier transform, the wavelet transform, and the wavelet packet transform provide an effective representation for classification, provided that they are subject to an appropriate form of dimensionality reduction.

14 July 2011 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HHHe Huang
He Huang
FZFan Zhang
Fan Zhang
LHLevi J. Hargrove
Levi J. Hargrove
ZDZhi Dou
Zhi Dou
DRDaniel R. Rogers
Daniel R. Rogers
KEKevin B. Englehart
Kevin B. Englehart
In this study, we developed an algorithm based on neuromuscular-mechanical fusion to continuously recognize a variety of locomotion modes performed by patients with transfemoral (TF) amputations. Electromyographic (EMG) signals recorded from gluteal and residual thigh muscles and ground reaction forces/moments measured from the prosthetic pylon were used as inputs to a phase-dependent pattern classifier for continuous locomotion-mode identification. The algorithm was evaluated using data collected from five patients with TF amputations. The results showed that neuromuscular-mechanical fusion outperformed methods that used only EMG signals or mechanical information. For continuous performance of one walking mode (i.e., static state), the interface based on neuromuscular-mechanical fusion and a support vector machine (SVM) algorithm produced 99% or higher accuracy in the stance phase and 95% accuracy in the swing phase for locomotion-mode recognition. During mode transitions, the fusion-based SVM method correctly recognized all transitions with a sufficient predication time. These promising results demonstrate the potential of the continuous locomotion-mode classifier based on neuromuscular-mechanical fusion for neural control of prosthetic legs.

25 December 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
AAAli Ameri
Ali Ameri
MAMohammad Ali Akhaee
Mohammad Ali Akhaee
ESErik Scheme
Erik Scheme
KEKevin Englehart
Kevin Englehart
An important barrier to commercialization of pattern recognition myoelectric control of prostheses is the lack of robustness to confounding factors such as electrode shift, skin impedance variations, and learning effects. To overcome this challenge, a novel supervised adaptation approach based on transfer learning (TL) with convolutional neural networks (CNNs) is proposed which requires only a short training session (a few seconds for each class) to recalibrate the system. TL is proposed as a solution to the problem of insufficient calibration data due to short training times for both classification and regression-based control schemes. This approach was validated for electrode shift of roughly 2.5cm with 13 able-bodied subjects to estimate individual and combined wrist motions. With this method, the original CNN (trained before the shift) was fine-tuned with the calibration data from after shifting. The results show that the proposed technique outperforms training a CNN from scratch (random initialization of weights) or a support vector machine (SVM) using the minimal calibration data. Moreover, it demonstrates superior performance than previous LDA and QDA-based adaptation approaches. As the outcomes confirm, the proposed CNN TL method provides a practical solution for adaptation to external factors, improving the robustness of electromyogram (EMG) pattern recognition systems.

16 April 2019 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
AAAli Ameri
Ali Ameri
MAMohammad Ali Akhaee
Mohammad Ali Akhaee
ESErik Scheme
Erik Scheme
KEKevin Englehart
Kevin Englehart
Objective . Deep learning models can learn representations of data that extract useful information in order to perform prediction without feature engineering. In this paper, an electromyography (EMG) control scheme with a regression convolutional neural network (CNN) is proposed as a substitute of conventional regression models that use purposefully designed features. Approach . The usability of the regression CNN model is validated for the first time, using an online Fitts’ law style test with both individual and simultaneous wrist motions. Results were compared to that of a support vector regression-based scheme with a group of widely used extracted features. Main results . In spite of the proven efficiency of these well-known features, the CNN-based system outperformed the support vector machine (SVM) based scheme in throughput, due to higher regression accuracies especially with high EMG amplitudes. Significance . These results indicate that the CNN model can extract underlying motor control information from EMG signals during single and multiple degree-of-freedom (DoF) tasks. The advantage of regression CNN over classification CNN (studied previously) is that it allows independent and simultaneous control of motions.