Erik Scheme

Dr. Erik Scheme

Institute of Biomedical Engineering, University of New Brunswick, Fredericton, NB, Canada
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Angkoon PhinyomarkAngkoon Phinyomark
Angkoon Phinyomark
RKRami N. Khushaba
Rami N. Khushaba
ESErik Scheme
Erik Scheme
Specialized myoelectric sensors have been used in prosthetics for decades, but, with recent advancements in wearable sensors, wireless communication and embedded technologies, wearable electromyographic (EMG) armbands are now commercially available for the general public. Due to physical, processing, and cost constraints, however, these armbands typically sample EMG signals at a lower frequency (e.g., 200 Hz for the Myo armband) than their clinical counterparts. It remains unclear whether existing EMG feature extraction methods, which largely evolved based on EMG signals sampled at 1000 Hz or above, are still effective for use with these emerging lower-bandwidth systems. In this study, the effects of sampling rate (low: 200 Hz vs. high: 1000 Hz) on the classification of hand and finger movements were evaluated for twenty-six different individual features and eight sets of multiple features using a variety of datasets comprised of both able-bodied and amputee subjects. The results show that, on average, classification accuracies drop significantly ( p < 0.05) from 2% to 56% depending on the evaluated features when using the lower sampling rate, and especially for transradial amputee subjects. Importantly, for these subjects, no number of existing features can be combined to compensate for this loss in higher-frequency content. From these results, we identify two new sets of recommended EMG features (along with a novel feature, L-scale) that provide better performance for these emerging low-sampling rate systems.

Verified
Journal Article
Open access
PDF file
Angkoon PhinyomarkAngkoon Phinyomark
Angkoon Phinyomark
ESErik Scheme
Erik Scheme
The increasing amount of data in electromyographic (EMG) signal research has greatly increased the importance of developing advanced data analysis and machine learning techniques which are better able to handle “big data”. Consequently, more advanced applications of EMG pattern recognition have been developed. This paper begins with a brief introduction to the main factors that expand EMG data resources into the era of big data, followed by the recent progress of existing shared EMG data sets. Next, we provide a review of recent research and development in EMG pattern recognition methods that can be applied to big data analytics. These modern EMG signal analysis methods can be divided into two main categories: (1) methods based on feature engineering involving a promising big data exploration tool called topological data analysis; and (2) methods based on feature learning with a special emphasis on “deep learning”. Finally, directions for future research in EMG pattern recognition are outlined and discussed.

25 December 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
AAAli Ameri
Ali Ameri
MAMohammad Ali Akhaee
Mohammad Ali Akhaee
ESErik Scheme
Erik Scheme
KEKevin Englehart
Kevin Englehart
An important barrier to commercialization of pattern recognition myoelectric control of prostheses is the lack of robustness to confounding factors such as electrode shift, skin impedance variations, and learning effects. To overcome this challenge, a novel supervised adaptation approach based on transfer learning (TL) with convolutional neural networks (CNNs) is proposed which requires only a short training session (a few seconds for each class) to recalibrate the system. TL is proposed as a solution to the problem of insufficient calibration data due to short training times for both classification and regression-based control schemes. This approach was validated for electrode shift of roughly 2.5cm with 13 able-bodied subjects to estimate individual and combined wrist motions. With this method, the original CNN (trained before the shift) was fine-tuned with the calibration data from after shifting. The results show that the proposed technique outperforms training a CNN from scratch (random initialization of weights) or a support vector machine (SVM) using the minimal calibration data. Moreover, it demonstrates superior performance than previous LDA and QDA-based adaptation approaches. As the outcomes confirm, the proposed CNN TL method provides a practical solution for adaptation to external factors, improving the robustness of electromyogram (EMG) pattern recognition systems.

10 February 2011 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
ESErik Scheme
Erik Scheme
KEKevin B. Englehart
Kevin B. Englehart
BHBernard S. Hudgins
Bernard S. Hudgins
Recent literature in pattern recognition-based myoelectric control has highlighted a disparity between classification accuracy and the usability of upper limb prostheses. This paper suggests that the conventionally defined classification accuracy may be idealistic and may not reflect true clinical performance. Herein, a novel myoelectric control system based on a selective multiclass one-versus-one classification scheme, capable of rejecting unknown data patterns, is introduced. This scheme is shown to outperform nine other popular classifiers when compared using conventional classification accuracy as well as a form of leave-one-out analysis that may be more representative of real prosthetic use. Additionally, the classification scheme allows for real-time, independent adjustment of individual class-pair boundaries making it flexible and intuitive for clinical use.

13 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ECEvan Campbell
Evan Campbell
Angkoon PhinyomarkAngkoon Phinyomark
Angkoon Phinyomark
ESErik Scheme
Erik Scheme
This manuscript presents a hybrid study of a comprehensive review and a systematic (research) analysis. Myoelectric control is the cornerstone of many assistive technologies used in clinical practice, such as prosthetics and orthoses, and human-computer interaction, such as virtual reality control. Although the classification accuracy of such devices exceeds 90% in a controlled laboratory setting, myoelectric devices still face challenges in robustness to variability of daily living conditions. The intrinsic physiological mechanisms limiting practical implementations of myoelectric devices were explored: the limb position effect and the contraction intensity effect. The degradation of electromyography (EMG) pattern recognition in the presence of these factors was demonstrated on six datasets, where classification performance was 13% and 20% lower than the controlled setting for the limb position and contraction intensity effect, respectively. The experimental designs of limb position and contraction intensity literature were surveyed. Current state-of-the-art training strategies and robust algorithms for both effects were compiled and presented. Recommendations for future limb position effect studies include: the collection protocol providing exemplars of at least 6 positions (four limb positions and three forearm orientations), three-dimensional space experimental designs, transfer learning approaches, and multi-modal sensor configurations. Recommendations for future contraction intensity effect studies include: the collection of dynamic contractions, nonlinear complexity features, and proportional control.

1 December 2020 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
FBFady S. Botros
Fady S. Botros
Angkoon PhinyomarkAngkoon Phinyomark
Angkoon Phinyomark
ESErik Scheme
Erik Scheme
Despite a historical focus on prosthetics, the incorporation of electromyography (EMG) sensors into less obtrusive wearable designs has recently gained attention as a potential human–computer interaction scheme for general consumer use. Because consumers are more used to wrist-worn devices, this article presents a comprehensive and systematic investigation of the feasibility of hand gesture recognition using EMG signals recorded at the wrist. A direct comparison of signal and information quality is conducted between concurrently recorded wrist and forearm signals. Both signals were collected simultaneously from 21 subjects while they performed a selection of 17 different single-finger gestures, multifinger gestures, and wrist gestures. Wrist EMG signals yielded consistently higher ( $p< 0.05$ ) signal quality metrics than forearm signals for gestures that involved fine finger movements, while maintaining comparable quality for wrist gestures. Similarly, the performance of both individual state-of-the-art EMG features and a standard feature set was found to be significantly better when using wrist signals for single and multifinger gestures, and comparable for wrist gestures. Classifiers trained and tested using wrist EMG signals achieved average accuracy levels of 92.1% for single-finger gestures, 91.2% for multifinger gestures, and 94.7% for the conventional wrist gestures. In conclusion, this article clearly demonstrates the feasibility of using wrist EMG signals for hand gesture recognition. Results highlight not only the promise of this approach, but also the viability of incorporating prior knowledge from the prosthetics field in the design of wrist-based EMG pattern recognition systems.