Kaushik Das Sharma

Kaushik Das Sharma

Auto-generated profile, based on publicly available information

Kaushik Das Sharma

University of Calcutta

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2012 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
KSKaushik Das Sharma
Kaushik Das Sharma
ACAmitava Chatterjee
Amitava Chatterjee
ARAnjan Rakshit
Anjan Rakshit
This paper proposes a novel methodology for autonomous mobile robot navigation utilizing the concept of tracking control. Vision-based path planning and subsequent tracking are performed by utilizing proposed stable adaptive state feedback fuzzy tracking controllers designed using the Lyapunov theory and particle-swarm-optimization (PSO)-based hybrid approaches. The objective is to design two self-adaptive fuzzy controllers, for -direction and -direction movements, optimizing both its structures and free parameters, such that the designed controllers can guarantee desired stability and, simultaneously, can provide satisfactory tracking performance for the vision-based navigation of mobile robot. The design methodology for the controllers simultaneously utilizes the global search capability of PSO and Lyapunov-theory-based local search method, thus providing a high degree of automation. Two different variants of hybrid approaches have been employed in this work. The proposed schemes have been implemented in both simulation and experimentations with a real robot, and the results demonstrate the usefulness of the proposed concept.

7 October 2020 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
MRMonalisa Singha Roy
Monalisa Singha Roy
BRBiplab Roy
Biplab Roy
RGRajarshi Gupta
Rajarshi Gupta
KSKaushik Das Sharma
Kaushik Das Sharma
Photoplethysmographic (PPG) measurements from ambulatory subjects may suffer from unreliability due to body movements and missing data segments due to loosening of sensor. This paper describes an on-device reliability assessment from PPG measurements using a stack denoising autoencoder (SDAE) and multilayer perceptron neural network (MLPNN). The missing segments were predicted by a personalized convolutional neural network (CNN) and long-short term memory (LSTM) model using a short history of the same channel data. Forty sets of volunteers' data, consisting of equal share of healthy and cardiovascular subjects were used for validation and testing. The PPG reliability assessment model (PRAM) achieved over 95% accuracy for correctly identifying acceptable PPG beats out of total 5000 using expert annotated data. Disagreement with experts' annotation was nearly 3.5%. The missing segment prediction model (MSPM) achieved a root mean square error (RMSE) of 0.22, and mean absolute error (MAE) of 0.11 for 40 missing beats prediction using only four beat history from the same channel PPG. The two models were integrated in a standalone device based on quad-core ARM Cortex-A53, 1.2 GHz, with 1 GB RAM, with 130 MB memory requirement and latency ~0.35 s per beat prediction with a 30 s frame. The present method also provides improved performance with published works on PPG quality assessment and missing data prediction using two public datasets, CinC and MIMIC-II under PhysioNet.

22 January 2010 in IEEE Transactions on Control Systems Technology
Verified
Journal Article
Closed access
KSKaushik Das Sharma
Kaushik Das Sharma
ACAmitava Chatterjee
Amitava Chatterjee
ARAnjan Rakshit
Anjan Rakshit
This brief proposes hybrid stable adaptive fuzzy controller design procedures utilizing the conventional Lyapunov theory and, the relatively newly devised harmony search (HS) algorithm-based stochastic approach. The objective is to design a self-adaptive fuzzy controller, optimizing both its structures and free parameters, such that the designed controller can guarantee desired stability and simultaneously it can provide satisfactory performance with a high degree of automation in the design process. Two different variants of the hybrid controller are proposed in this work. These variants are implemented for a benchmark simulation case study and real-life experimentation. The results obtained demonstrate the usefulness of the proposed approach.

18 March 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SASamiul Alam
Samiul Alam
RGRajarshi Gupta
Rajarshi Gupta
KSKaushik Das Sharma
Kaushik Das Sharma
Photoplethysmography (PPG) is a popular diagnostic tool for the assessment of various cardiovascular functions. Under continuous ambulatory measurements, PPG data get corrupted due to motion artifact (MA). Thus, on-board pulse signal quality assessment (SQA) before transmission can save the battery life of the wearable device for portable health monitoring applications. This article describes an SQA guided compression (SQAGC) of PPG data using a modified gain-shaped vector quantization (GSVQ) technique. The SQA was performed using kurtosis and autocorrelation to generate a binary classification rule to detect good quality pulses. Only these were considered for further compression. A notable contribution is reconstruction error minimization using the extracted features from the residual signal using a deep autoencoder (DAE), achieving a low percentage root-mean-squared difference (PRD). The SQAGC technique was evaluated using public databases like MIMIC-II, BIDMC, and PRRB as well as with real volunteers’ PPG collected in the laboratory environment. The SQA achieved an accuracy of 96.5% to identify good quality PPG segments out of expert annotated 9200 beats. The compression factor (and PRD) with 400 min duration data from Physionet MIMIC-II, BIDMC, PRRB, and volunteers’ data were 15.8 (and 0.31), 15.7 (and 0.21), 17.8 (and 0.33), and 18.2 (and 0.59), respectively, using 12-bit resolution and 125 Hz sampling. A real-time on-device implementation using quad-core ARM Cortex-A53, 1.2 GHz, supported by 1 GB RAM, achieved a latency of 546 ms with 327 kB of memory engagement for a 3 s PPG window. The compression ratio (CR) achieved comparable results, while PRD outperforms the published results using MIMIC-II data set.


6 October 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MRMonalisa Singha Roy
Monalisa Singha Roy
RGRajarshi Gupta
Rajarshi Gupta
KSKaushik Das Sharma
Kaushik Das Sharma
Research on noninvasive blood pressure (NIBP) measurement using electrocardiogram (ECG)/ photoplethysmogram (PPG) and their combinations have been most popular in ambulatory health monitoring. The real challenge is motion artifact (MA) corruption in the PPG, which makes the BP measurement unreliable. This paper presents BePCon, a deep learning-based model for beat-to-beat (BtB) BP measurement using a temporal convolutional network (TCN). Initially, the signal quality assessment (SQA) of PPG is done by a self-organizing map (SOM). Next, the time-domain, statistical, wavelet and stacked autoencoder features from current and previous good quality PPG cycles are extracted. A recursive feature elimination (RFE) selects optimum set of 20 features from each cycle before being fed to the TCN to predict the systolic (SBP) and diastolic blood pressure (DBP) of current beat. While evaluated over 150 data records from PhysioNet MIMIC-II/III waveform database, BePCon achieves standard deviation (SD), and mean absolute error (MAE) of 3.24 mmHg and 2.38 mmHg respectively for SBP, and 1.73 mmHg, and 1.23 mmHg respectively for the DBP respectively. An improvement of accuracy by a factor of 19.56% for SBP and 24.61% for DBP is obtained over without SQA. BePCon also complies with AAMI and BHS Grade A standard and improvement over published works on BtB BP measurement using MIMIC-II/III waveform database. A standalone implementation with a single core 1-GHz ARM v6 controller supported by 512 MB RAM shows low latency (~2.5 s per beat) and low memory requirement (~32.22 KB per beat). This establishes that BePCon has the potential for real-time ambulatory BtB BP measurement.