Arash Aryana

Arash Aryana

Auto-generated profile, based on publicly available information

Arash Aryana

Mercy General Hospital and Dignity Health Heart and Vascular Institute, Sacramento, CA (A.A.).

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in Heart Rhythm
Verified
Journal Article
Closed access
AAArash Aryana
Arash Aryana
JBJames H. Baker
James H. Baker
MGMartin A. Espinosa Ginic
Martin A. Espinosa Ginic
DPDeep K. Pujara
Deep K. Pujara
MBMark R. Bowers
Mark R. Bowers
ANAndrea Natale
Andrea Natale

1 September 2017 in Heart Rhythm
Verified
Journal Article
Open access
AAArash Aryana
Arash Aryana
DKDavid N. Kenigsberg
David N. Kenigsberg
MKMarcin Kowalski
Marcin Kowalski
CKCharles H. Koo
Charles H. Koo
HLHae W. Lim
Hae W. Lim
KEKenneth A. Ellenbogen
Kenneth A. Ellenbogen
There are no recommendations on the optimal dosing for cryoablation of atrial fibrillation (Cryo-AF). The purpose of this study was to develop and prospectively test a Cryo-AF dosing protocol guided exclusively by time-to-pulmonary vein (PV) isolation (TT-PVI) in patients undergoing a first-time Cryo-AF. In this multicenter study, we examined the acute/long-term safety/efficacy of Cryo-AF using the proposed dosing algorithm (Cryo-AFDosing; n = 355) against a conventional, nonstandardized approach (Cryo-AFConventional; n = 400) in a nonrandomized fashion. Acute PV isolation was achieved in 98.9% of patients in Cryo-AFDosing (TT-PVI = 48 ± 16 seconds) vs 97.2% in Cryo-AFConventional (P = .18). Cryo-AFDosing was associated with shorter (149 ± 34 seconds vs 226 ± 46 seconds; P <.001) and fewer (1.7 ± 0.8 vs 2.9 ± 0.8; P <.001) cryoapplications, reduced overall ablation (16 ± 5 minutes vs 40 ± 14 minutes; P <.001), fluoroscopy time (13 ± 6 minutes vs 29 ± 13 minutes; P <.001), left atrial dwell time (51 ± 14 minutes vs 118 ± 25 minutes; P <.001), and total procedure time (84 ± 23 minutes vs 145 ± 49 minutes; P <.001) but similar nadir balloon temperature (-47°C ± 8°C vs -48°C ± 6°C; P = .41) and total thaw time (43 ± 27 seconds vs 45 ± 19 seconds; P = .09) as compared to Cryo-AFConventional. Adverse events (2.0% vs 2.7%; P = .48), including persistent phrenic nerve palsy (0.6% vs 1.2%; P = .33) and 12-month freedom from all atrial arrhythmias (82.5% vs 78.3%; P = .14), were similar between Cryo-AFDosing and Cryo-AFConventional. However, Cryo-AFDosing was specifically associated with fewer atypical atrial flutters/tachycardias during long-term follow-up (8.5% vs 13.5%; P = .02) as well as fewer late PV reconnections at redo procedures (5.0% vs 18.5%; P <.001). A novel Cryo-AF dosing algorithm guided by TT-PVI can help individualize the ablation strategy and yield improved procedural endpoints and efficiency as compared to a conventional, nonstandardized approach.

1 January 2022 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
PDF file
Christian-H HeegerChristian-H Heeger
Christian-H Heeger
CSChristian Sohns
Christian Sohns
APAlexander Pott
Alexander Pott
AMAndreas Metzner
Andreas Metzner
OIOsamu Inaba
Osamu Inaba
RTRoland Richard Tilz
Roland Richard Tilz
Background: Cryoballoon-based pulmonary vein isolation (PVI) has emerged as an effective treatment for atrial fibrillation. The most frequent complication during cryoballoon-based PVI is phrenic nerve injury (PNI). However, data on PNI are scarce. Methods: The YETI registry is a retrospective, multicenter, and multinational registry evaluating the incidence, characteristics, prognostic factors for PNI recovery and follow-up data of patients with PNI during cryoballoon-based PVI. Experienced electrophysiological centers were invited to participate. All patients with PNI during CB2 or third (CB3) and fourth-generation cryoballoon (CB4)-based PVI were eligible. Results: A total of 17 356 patients underwent cryoballoon-based PVI in 33 centers from 10 countries. A total of 731 (4.2%) patients experienced PNI. The mean time to PNI was 127.7±50.4 seconds, and the mean temperature at the time of PNI was −49±8°C. At the end of the procedure, PNI recovered in 394/731 patients (53.9%). Recovery of PNI at 12 months of follow-up was found in 97.0% of patients (682/703, with 28 patients lost to follow-up). A total of 16/703 (2.3%) reported symptomatic PNI. Only 0.06% of the overall population showed symptomatic and permanent PNI. Prognostic factors improving PNI recovery are immediate stop at PNI by double-stop technique and utilization of a bonus-freeze protocol. Age, cryoballoon temperature at PNI, and compound motor action potential amplitude loss >30% were identified as factors decreasing PNI recovery. Based on these parameters, a score was calculated. The YETI score has a numerical value that will directly represent the probability of a specific patient of recovering from PNI within 12 months. Conclusions: The incidence of PNI during cryoballoon-based PVI was 4.2%. Overall 97% of PNI recovered within 12 months. Symptomatic and permanent PNI is exceedingly rare in patients after cryoballoon-based PVI. The YETI score estimates the prognosis after iatrogenic cryoballoon-derived PNI. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03645577. Graphic A graphic abstract is available for this article.

1 February 2021 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
AAArash Aryana
Arash Aryana
SAShelley L. Allen
Shelley L. Allen
DPDeep K. Pujara
Deep K. Pujara
MBMark R. Bowers
Mark R. Bowers
POPadraig Gearoid O’nEill
Padraig Gearoid O’nEill
ANAndrea Natale
Andrea Natale

30 July 2016 in Journal of Interventional Cardiac Electrophysiology
Verified
Journal Article
Closed access
PDF file
AAArash Aryana
Arash Aryana
SSSheldon M. Singh
Sheldon M. Singh
Giacomo MugnaiGiacomo Mugnai
Giacomo Mugnai
Carlo de AsmundisCarlo de Asmundis
Carlo de Asmundis
MKMarcin Kowalski
Marcin Kowalski
GCGian-Battista Chierchia
Gian-Battista Chierchia

1 December 2016 in Heart Rhythm
Verified
Journal Article
Open access
AAArash Aryana
Arash Aryana
MKMarcin Kowalski
Marcin Kowalski
POPadraig Gearoid O’nEill
Padraig Gearoid O’nEill
CKCharles H. Koo
Charles H. Koo
HLHae W. Lim
Hae W. Lim
KEKenneth A. Ellenbogen
Kenneth A. Ellenbogen
Limited data exist on cryoablation of atrial fibrillation (Cryo-AF) using the newly available third-generation (Arctic Front Advance-Short Tip [AFA-ST]) cryoballoon. In this multicenter study, we evaluated the safety and efficacy of Cryo-AF using the AFA-ST vs the second-generation (Arctic Front Advance [AFA]) cryoballoon. We examined the procedural safety and efficacy and the short- and long-term clinical outcomes associated with a first-time Cryo-AF performed in 355 consecutive patients (254/355 [72%] with paroxysmal AF), using either the AFA-ST (n = 102) or the AFA (n = 253) cryoballoon catheters. Acute isolation was achieved in 99.6% of all pulmonary veins (PVs) (AFA-ST: 100% vs AFA: 99.4%; P = .920). Time to pulmonary vein isolation was recorded in 89.2% of PVs using AFA-ST vs 60.2% using AFA (P < .001). PVs targeted using AFA-ST required fewer applications (1.6 ± 0.8 vs 1.7 ± 0.8; P = .023), whereas there were no differences in the balloon nadir temperature (AFA-ST: -47.0°C ± 7.3°C vs AFA: -47.5°C ± 7.8°C; P = .120) or thaw time (AFA-ST: 41 ± 24 seconds vs AFA: 44 ± 28 seconds; P = .056). However, AFA-ST was associated with shorter left atrial dwell time (43 ± 5 minutes vs 53 ± 16 minutes; P < .001) and procedure time (71 ± 11 minutes vs 89 ± 25 minutes; P < .001). Furthermore, Cryo-AF using AFA-ST was completed more frequently by "single-shot" PV ablation (27.4% vs 20.2%; P = .031). Persistent phrenic nerve palsy (AFA-ST: 0% vs AFA: 0.8%; P = .507) and procedure-related adverse events (AFA-ST: 1.0% vs AFA: 1.6%; P = .554) were similar, as was the freedom from recurrent atrial arrhythmias at 10 months of follow-up (AFA-ST: 81.8% vs AFA: 79.9%; P = .658). Cryo-AF using the AFA-ST cryoballoon offers an enhanced ability to assess time to pulmonary vein isolation, allowing for fewer cryoapplications and shorter left atrial dwell time and procedure time. Consequently, this allowed for procedural completion more frequently using a "single-shot" PV ablation with equivalent safety and efficacy.