Swee Yong Chee

Swee Yong Chee

Auto-generated profile, based on publicly available information

Swee Yong Chee

Faculty of Science, Universiti Tunku Abdul Rahman, Malaysia

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2010 in Journal of Applied Phycology
Verified
Journal Article
Closed access
PDF file
SCSwee-Yong Chee
Swee-Yong Chee
PWPing-Keong Wong
Ping-Keong Wong
CWChing-Lee Wong
Ching-Lee Wong

1 October 2016 in Materials & Design
Verified
Journal Article
Closed access
RSR. Shanti
R. Shanti
Federico BellaFederico Bella
Federico Bella
YSY.S. Salim
Y.S. Salim
SCS.Y. Chee
S.Y. Chee
RTRamesh T.Subramaniam
Ramesh T.Subramaniam
Ramesh KasiRamesh Kasi
Ramesh Kasi

22 December 2016 in RSC Advances
Verified
Journal Article
Open access
PDF file
RSR. Shanti
R. Shanti
AHA. N. Hadi
A. N. Hadi
YSY. S. Salim
Y. S. Salim
SCS. Y. Chee
S. Y. Chee
RTRamesh T.Subramaniam
Ramesh T.Subramaniam
Ramesh KasiRamesh Kasi
Ramesh Kasi
A new acrylic terpolymer, poly(methyl methacrylate-co-butyl acrylate-co-acrylic acid) [P(MMA-co-BA-co-AA)] of ultra-high molecular weight (UHMW) was synthesized via seeded emulsion polymerization. This polyacrylic showed good film properties; high transparency, water resistance and mechanical flexibility that may suitable for many environmental based applications such as coating, packaging, label sensors etc. In order to access the photo-stability of this material for environmental application, studies were conducted under UV illumination of a short-wavelength (λ = 254 nm) in air. The responses were collected at different irradiation times by using several characterization techniques: infrared/UV-visible spectroscopy (FTIR/UV-Vis), gel permeation chromatography (GPC), atomic force microscopy (AFM) and thermogravimetric analysis (TGA). Two distinguishable structures, cross-linked and fragmented chains, were formed under photo-irradiation at different times of exposure. The formation of cross-linked structures at short irradiation times (t < 60 min) increases the chain length as validated from the increase in average-molecular weight (Mw), whilst at longer irradiation time the fragmentation causes a decrease in the chain length (decrease in Mw). Only the chain scission at longer irradiation time (t > 60 min) causes the copolymer to degrade. The centre of reaction was identified at the pendent group and no effect of main chain destabilization was observed throughout the experimental condition. The occurrence of chain cleavage during photo-degradation causes chain–chain separation, as visually seen under the imaging technique and this coincides with the observed drop in thermal stability. Photo-oxidation was also proposed to occur simultaneously with photo-degradation as the irradiation was performed in air.

1 September 2011 in Polymer Degradation and Stability
Verified
Journal Article
Closed access
YPYing-Ning Phang
Ying-Ning Phang
SCSwee-Yong Chee
Swee-Yong Chee
CLChee-Onn Lee
Chee-Onn Lee
YTYok-Lan Teh
Yok-Lan Teh

28 July 2017 in Materials
Verified
Journal Article
Open access
PDF file
SKShin Yiing Kee
Shin Yiing Kee
YMYamuna Munusamy
Yamuna Munusamy
KOKok Seng Ong
Kok Seng Ong
HMHenk Metselaar
Henk Metselaar
SCSwee Yong Chee
Swee Yong Chee
KLKoon Chun Lai
Koon Chun Lai
The composite PCM was prepared by blending polymethyl methacrylate (PMMA) and myristic acid (MA) in different weight percentages. The MA and PMMA were selected as PCM and supporting material, respectively. As liquid MA may leak out during the phase transition, this study proposes the use of two coatings, namely a polyacrylic coating and a conformal coating to overcome the leakage problem. Both coatings were studied in terms of the leakage test, chemical compatibility, thermal stability, morphology, and reliability. No leakage was found in the PCMs with coatings compared to those without under the same proportions of MA/PMMA, thus justifying the use of coatings in the present study. The chemically compatibility was confirmed by FTIR spectra: the functional groups of PCMs were in accordance with those of coatings. DSC showed that the coatings did not significantly change the melting and freezing temperatures, however, they improved the thermal stability of composite PCMs as seen in TGA analysis. Furthermore, the composite PCMs demonstrated good thermal reliability after 1000 times thermal cycling. The latent heat of melting reduced by only 0.16% and 1.02% for the PCMs coated with conformal coating and polyacrylic coating, respectively. Therefore, the proposed coatings can be considered in preparing fatty acid/PMMA blends attributed to the good stability, compatibility and leakage prevention.

1 March 2017 in Journal of Cleaner Production
Verified
Journal Article
Closed access
HNHumayun Nadeem
Humayun Nadeem
NHNoor Zainab Dubai Habib
Noor Zainab Dubai Habib
CNChoon Aun Ng
Choon Aun Ng
SZSalah Elias Zoorob
Salah Elias Zoorob
ZMZahiraniza Mustaffa
Zahiraniza Mustaffa
MYMuhammad Younas
Muhammad Younas