Florian Aubermann

Florian Aubermann

Auto-generated profile, based on publicly available information

Florian Aubermann

Max Planck Institute for Medical Research@Bildungscampus Heilbronn, Dept. of Cellular Biophysics

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2024 in ACS Omega
Verified
Journal Article
Open access
JLJacqueline A. De Lora
Jacqueline A. De Lora
FAFlorian Aubermann
Florian Aubermann
CFChristoph Frey
Christoph Frey
TJTimotheus Jahnke
Timotheus Jahnke
YWYuanzhen Wang
Yuanzhen Wang
JSJoachim Pius Spatz
Joachim Pius Spatz
Acoustophoretic forces have been successfully implemented into droplet-based microfluidic devices to manipulate droplets. These acoustophoretic forces in droplet microfluidic devices are typically generated as in acoustofluidic devices through transducer actuation of a piezoelectric substrate such as lithium niobate (LiNbO3), which is inherently accompanied by the emergence of electrical fields. Understanding acoustophoretic versus dielectrophoretic forces produced by electrodes and transducers within active microfluidic devices is important for the optimization of device performance during design iterations. In this case study, we design microfluidic devices with a droplet injection module and report an experimental strategy to deduce the respective contribution of the acoustophoretic versus dielectrophoretic forces for the observed droplet injection. Our PDMS-based devices comprise a standard oil-in-water droplet-generating module connected to a T-junction injection module featuring actuating electrodes. We use two different electrode geometries produced within the same PDMS slab as the droplet production/injection channels by filling low-melting-point metal alloy into channels that template the electrode geometries. When these electrodes are constructed on LiNbO3 as the substrate, they have a dual function as a piezoelectric transducer, which we call embedded liquid metal interdigitated transducers (elmIDTs). To decipher the contribution of acoustophoretic versus dielectrophoretic forces, we build the same devices on either piezoelectric LiNbO3 or nonpiezo active glass substrates with different combinations of physical device characteristics (i.e., elmIDT geometry and alignment) and operate in a range of phase spaces (i.e., frequency, voltage, and transducer polarity). We characterize devices using techniques such as laser Doppler vibrometry (LDV) and infrared imaging, along with evaluating droplet injection for our series of device designs, constructions, and operating parameters. Although we find that LiNbO3 device designs generate acoustic fields, we demonstrate that droplet injection occurs only due to dielectrophoretic forces. We deduce that droplet injection is caused by the coupled dielectrophoretic forces arising from the operation of elmIDTs rather than by acoustophoretic forces for this specific device design. We arrive at this conclusion because equivalent droplet injection occurs without the presence of an acoustic field using the same electrode designs on nonpiezo active glass substrate devices. This work establishes a methodology to pinpoint the major contributing force of droplet manipulation in droplet-based acoustomicrofluidics.

21 April 2025 in Small Methods
Verified
Journal Article
Open access
FAFlorian Aubermann
Florian Aubermann
SSSenne Seneca
Senne Seneca
THTomáš Hofman
Tomáš Hofman
IGIrene Garcés‐Lázaro
Irene Garcés‐Lázaro
KAKarim Ajmail
Karim Ajmail
JSJoachim Pius Spatz
Joachim Pius Spatz
Natural Killer (NK) cells, as key effector cells of the innate immune system, display high heterogeneity in their ability to kill target cells. The underlying mechanisms remain poorly understood. Here, a droplet‐based microfluidic platform is presented to identify and select NK cells with serial killing ability. To this end, primary human NK cells are encapsulated with several target cells using an efficient negative pressure‐based droplet generator. Capitalizing on the large number of possible killing events due to quantization into droplets, a convolutional neural network analysis pipeline is developed to quantify the cytotoxicity and abundance of serial killing events with high accuracy. To physically select NK cells based on their serial killing ability, MultiCell‐Sort ‐ an advanced real‐time image‐based droplet sorting module ‐ is presented. While conventional single‐cell sorters mostly evaluate intrinsically‐encoded properties, such as protein expression levels, MultiCell‐Sort can select living NK cells based on complex functional phenotypes emerging from multiple cell‐cell interactions within the droplet. This novel microfluidic phenotyping platform hereby allows the potential integration of complementary techniques to provide an understanding of regulators and markers underlying the heterogeneous nature of NK cell functional phenotypes.

28 April 2025 in ACS Nano
Verified
Journal Article
Open access
YWYuanzhen Wang
Yuanzhen Wang
FAFlorian Aubermann
Florian Aubermann
JSJoachim Pius Spatz
Joachim Pius Spatz
A previously unknown mechanism for enhancing the diffusivity of lithium ions in liquid electrolytes is reported by immersing a charged copper surface in an electrolyte, which forms a laterally ultramobile Helmholtz layer at the copper-electrolyte interface. A microfluidic chip in combination with Raman spectroscopy and molecular ab initio dynamic simulations allowed for a quantitative study and mechanistic description of the diffusion enhancement. The synthesis of an ultrafine copper fiber fleece with a large copper surface area enables the fabrication of a 3-dimensional graphite/copper fleece composite electrode. Such electrodes demonstrate enhanced ion diffusivity and electrical conductivity compared to traditional electrodes without copper fleece but with copper foil. This electrode design allows electrochemically functional ultrathick anodes of up to 1.2 mm thickness and 32 mAh/cm2 areal capacity in half-cell format. The fleece electrodes use half the amount of copper compared to conventional foil-based electrodes and therefore provide significantly higher volumetric and gravimetric energy densities.