Christoph Frey

Christoph Frey

Auto-generated profile, based on publicly available information

Christoph Frey

Department of Cellular Biophysics, Max Planck Institute for Medical Research, Jahnstraße 29, 69120 Heidelberg, Germany

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2020 in View
Verified
Journal Article
Open access
PDF file
CFChristoph Frey
Christoph Frey
JPJonas Pfeil
Jonas Pfeil
TNTobias Neckernuss
Tobias Neckernuss
DGDaniel Geiger
Daniel Geiger
KWKlaus Weishaupt
Klaus Weishaupt
JSJoachim Pius Spatz
Joachim Pius Spatz
Droplet‐based microfluidic technology offers several benefits: the integration of multiple laboratory functions into a single microfabricated chip, manual intervention possibilities, minimal sample consumption, and increased analysis speed and data precision. These advantages have boosted the widespread application of this technology in biological and biomedical research. Despite recent progress, considerable challenges remain to be addressed for end‐user applications. This especially concerns the difficulty of creating powerful and easy to implement methods for real‐time analysis and active manipulation of passing droplets. Toward this end, we developed a very sensitive optical device equipped with smart algorithms for real‐time label‐free monitoring and active manipulation of passing droplets. We demonstrate the advanced properties of the developed optical device by measuring different droplet production parameters as well as the label‐free detection of cells in droplets. Moreover, the newly developed technology was connected with a function generator system to allow for subsequent manipulation of the monitored droplets based on the measured parameters. As an example, we performed electric field‐mediated, label‐free sorting of cell‐containing droplets from empty ones. Furthermore, we achieved an efficient size‐based separation of droplets. We envision that the developed optical device will be a useful tool for the online monitoring of passing droplets and will be implemented for the integration and automation of various droplet‐based microfluidic functional units.

23 March 2020 in ACS Omega
Verified
Journal Article
Open access
CFChristoph Frey
Christoph Frey
KGKerstin Göpfrich
Kerstin Göpfrich
SPSadaf Pashapour
Sadaf Pashapour
IPIlia Platzman
Ilia Platzman
JSJoachim Pius Spatz
Joachim Pius Spatz
Droplet-based microfluidics have emerged as an important tool for diverse biomedical and biological applications including, but not limited to, drug screening, cellular analysis, and bottom-up synthetic biology. Each microfluidic water-in-oil droplet contains a well-defined biocontent that, following its manipulation/maturation, has to be released into a physiological environment toward possible end-user investigations. Despite the progress made in recent years, considerable challenges still loom at achieving a precise control over the content release with sufficient speed and sensitivity. Here, we present a quantitative study in which we compare the effectiveness and biocompatibility of chemical and physical microfluidic release methods. We show the advantages of electrocoalescence of water-in-oil droplets in terms of high-throughput release applications. Moreover, we apply programmable DNA nanotechnology to achieve a segregation of the biochemical content within the droplets for the controlled filtration of the encapsulated materials. We envision that the developed bifunctional microfluidic approach, capable of content segregation and selective release, will expand the microfluidic toolbox for cell biology, synthetic biology, and biomedical applications.

10 December 2021 in ACS Synthetic Biology
Verified
Journal Article
Open access
FLFélix Lussier
Félix Lussier
MSMartin Schröter
Martin Schröter
NDNicolas J. Diercks
Nicolas J. Diercks
KJKevin Jahnke
Kevin Jahnke
CWCornelia Weber
Cornelia Weber
JSJoachim Pius Spatz
Joachim Pius Spatz
By using electrostatic interactions as driving force to assemble vesicles, the droplet-stabilized method was recently applied to reconstitute and encapsulate proteins, or compartments, inside giant unilamellar vesicles (GUVs) to act as minimal synthetic cells. However, the droplet-stabilized approach exhibits low production efficiency associated with the troublesome release of the GUVs from the stabilized droplets, corresponding to a major hurdle for the droplet-stabilized approach. Herein, we report the use of pH as a potential trigger to self-assemble droplet-stabilized GUVs (dsGUVs) by either bulk or droplet-based microfluidics. Moreover, pH enables the generation of compartmentalized GUVs with flexibility and robustness. By co-encapsulating pH-sensitive small unilamellar vesicles (SUVs), negatively charged SUVs, and/or proteins, we show that acidification of the droplets efficiently produces dsGUVs while sequestrating the co-encapsulated material. Most importantly, the pH-mediated assembly of dsGUVs significantly improves the production efficiency of free-standing GUVs (i.e., released from the stabilizing-droplets) compared to its previous implementation.

28 March 2024 in ACS Omega
Verified
Journal Article
Open access
JLJacqueline A. De Lora
Jacqueline A. De Lora
FAFlorian Aubermann
Florian Aubermann
CFChristoph Frey
Christoph Frey
TJTimotheus Jahnke
Timotheus Jahnke
YWYuanzhen Wang
Yuanzhen Wang
JSJoachim Pius Spatz
Joachim Pius Spatz
Acoustophoretic forces have been successfully implemented into droplet-based microfluidic devices to manipulate droplets. These acoustophoretic forces in droplet microfluidic devices are typically generated as in acoustofluidic devices through transducer actuation of a piezoelectric substrate such as lithium niobate (LiNbO3), which is inherently accompanied by the emergence of electrical fields. Understanding acoustophoretic versus dielectrophoretic forces produced by electrodes and transducers within active microfluidic devices is important for the optimization of device performance during design iterations. In this case study, we design microfluidic devices with a droplet injection module and report an experimental strategy to deduce the respective contribution of the acoustophoretic versus dielectrophoretic forces for the observed droplet injection. Our PDMS-based devices comprise a standard oil-in-water droplet-generating module connected to a T-junction injection module featuring actuating electrodes. We use two different electrode geometries produced within the same PDMS slab as the droplet production/injection channels by filling low-melting-point metal alloy into channels that template the electrode geometries. When these electrodes are constructed on LiNbO3 as the substrate, they have a dual function as a piezoelectric transducer, which we call embedded liquid metal interdigitated transducers (elmIDTs). To decipher the contribution of acoustophoretic versus dielectrophoretic forces, we build the same devices on either piezoelectric LiNbO3 or nonpiezo active glass substrates with different combinations of physical device characteristics (i.e., elmIDT geometry and alignment) and operate in a range of phase spaces (i.e., frequency, voltage, and transducer polarity). We characterize devices using techniques such as laser Doppler vibrometry (LDV) and infrared imaging, along with evaluating droplet injection for our series of device designs, constructions, and operating parameters. Although we find that LiNbO3 device designs generate acoustic fields, we demonstrate that droplet injection occurs only due to dielectrophoretic forces. We deduce that droplet injection is caused by the coupled dielectrophoretic forces arising from the operation of elmIDTs rather than by acoustophoretic forces for this specific device design. We arrive at this conclusion because equivalent droplet injection occurs without the presence of an acoustic field using the same electrode designs on nonpiezo active glass substrate devices. This work establishes a methodology to pinpoint the major contributing force of droplet manipulation in droplet-based acoustomicrofluidics.

25 August 2021 in bioRxiv
Verified
Preprint
Open access
PDF file
FLFélix Lussier
Félix Lussier
MSMartin Schröter
Martin Schröter
NDNicolas J. Diercks
Nicolas J. Diercks
KJKevin Jahnke
Kevin Jahnke
CWCornelia Weber
Cornelia Weber
JSJoachim Pius Spatz
Joachim Pius Spatz
Bottom-up synthetic biology thrives to reconstruct basic cellular processes into a minimalist cellular replica to foster their investigation in greater details with a reduced number of variables. Among these cellular features, the endomembrane system is an important aspect of cells which is at the origin of many of their functions. Still, the reconstruction of these inner compartments within a lipid-based vesicle remains challenging and poorly controlled. Herein, we report the use of pH as external trigger to self-assemble compartmentalized giant unilamellar vesicles (GUVs) by either bulk, or droplet-based microfluidics. By co-encapsulating pH sensitive small unilamellar vesicles (SUVs), negatively charged SUVs and/or proteins, we show that acidification of the droplets efficiently produces GUVs while sequestrating the co-encapsulated material with flexibility and robustness. The method enables the simultaneous reconstruction of more than a single cellular phenotype from the bottom-up, corresponding to an important advancement in the current status quo of bottom-up synthetic biology.

4 May 2022 in ChemRxiv
Verified
Preprint
Open access
PDF file
CFChristoph Frey
Christoph Frey
JLJacqueline A. De Lora
Jacqueline A. De Lora
TJTimotheus Jahnke
Timotheus Jahnke
YWYuanzhen Wang
Yuanzhen Wang
SWSebastian Weber
Sebastian Weber
JSJoachim P. Spatz
Joachim P. Spatz
We present an all-in-one acoustofluidics device for controlled acoustic field-mediated injection of surfactant stabilized water-in-oil droplets. The microfluidic channels and interdigitated transducer (IDT) channels are produced on the same master wafer and cast within one PDMS slab, making our acoustofluidics device simple to construct while retaining the same height for all channels. The IDTs with a curved, serpentine, paired and focusing geometry are easily embedded into the PDMS slab by filling the IDT channels with low melting point metal alloy. In this article, we propose the working mechanism of our embedded IDTs, which we call acoustoinjection, and carry out a precise characterization by laser doppler vibrometry (LDV) and infrared imaging to describe the injection of droplets within microfluidic channels. Although we observe that the device has acoustic resonance in the MHz frequency domain, we show that it operates most efficiently for acoustoinjection in the kHz frequency domain. In this frequency domain, our acoustofluidics device generates a pressure wave that causes destabilization of the surfactant-supported droplet interface enabling the injection of aqueous solution into the water-phase of the droplet with minimum heat generation. We show droplet injection for different surfactant concentrations, droplet passing speeds, and injection rates with high accuracy. This integrated device has the potential to serve as an alternative to electric field mediated picoinjection technologies by acoustic field-mediated and non-harmful manipulation of droplets with bio-content.