In-Seop Lee

In-Seop Lee

Auto-generated profile, based on publicly available information

In-Seop Lee

Institute of Natural Sciences, Yonsei University

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
PDF file
JLJung-seok Lee
Jung-seok Lee
JYJin-Hyuk Yang
Jin-Hyuk Yang
JHJi-Youn Hong
Ji-Youn Hong
UJUi-Won Jung
Ui-Won Jung
HYHyeong-Cheol Yang
Hyeong-Cheol Yang
SCSeong-Ho Choi
Seong-Ho Choi
Lee JS, et al. J Periodontal Implant Sci. 2014 Oct;44(5):242-250. https://doi.org/10.5051/jpis.2014.44.5.242

1 February 2007 in Surface and Coatings Technology
Verified
Journal Article
Closed access
MLMi Hee Lee
Mi Hee Lee
Dong-Wook HanDong-Wook Han
Dong-Wook Han
HBHyun Sook Baek
Hyun Sook Baek
HLHye Ryun Lim
Hye Ryun Lim
ILIn-Seop Lee
In-Seop Lee
JPJong-Chul Park
Jong-Chul Park

1 August 2026 in Biomedical Materials
Verified
Journal Article
Closed access
PDF file
SLSijing Lin
Sijing Lin
TGTiantian Gao
Tiantian Gao
SCSung-Min Chung
Sung-Min Chung
ILIn-Seop Lee
In-Seop Lee
CCCen Chen
Cen Chen
Bimetallic structures integrating Ti6Al4V and CoCrMo alloys present a promising strategy for advanced orthopedic implants by synergistically combining high fracture toughness with excellent wear resistance. However, the direct fabrication of these dissimilar metals via selective laser melting (SLM) is significantly hindered by metallurgical incompatibility and high residual stress, which frequently lead to interfacial delamination and edge warping. In this study, a CoCrMo-Ti6Al4V bimetallic composite was successfully fabricated using SLM. To overcome manufacturing defects, a CoCrMo transition layer printed with low laser energy density was employed as a mechanical buffer to mitigate residual stresses, while optimized external support structures provided physical anchoring to suppress geometric distortion. The microstructural evolution, elemental distribution, and phase composition were systematically characterized using field-emission scanning electron microscopy, energy-dispersive x-ray spectroscopy, and x-ray diffraction. Mechanical performance was evaluated through hardness and sliding wear tests, while the biological response was assessed using human bone marrow mesenchymal stem cells (BMSCs). The results demonstrated that the three-layer architecture effectively eliminated macroscopic defects and ensured structural integrity. Furthermore, the composite exhibited a substantial enhancement in surface hardness and wear resistance, achieving an interfacial bonding strength of 43.21 ± 1.07 MPa. Fracture analysis revealed a cohesive failure mode within the transition layer, indicating robust metallurgical bonding between the dissimilar components. In vitro assessments confirmed excellent cytocompatibility, exhibiting high cell viability (>95%) and proliferation on the composite surfaces. Ultimately, this research establishes a reliable fabrication methodology for complex bimetallic components, offering broad application prospects in personalized medical devices, joint replacements, and tissue engineering.