Xiaoyang Qiao

Xiaoyang Qiao

Auto-generated profile, based on publicly available information

Xiaoyang Qiao

Department of Biomedical Engineering, School of Life Science and Technology, Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Xian Jiaotong University, Xian, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
XQXiaoyang Qiao
Xiaoyang Qiao
YWYu Wen
Yu Wen
JYJianjun Yu
Jianjun Yu
ABAyache Bouakaz
Ayache Bouakaz
YZYujin Zong
Yujin Zong
MWMingxi Wan
Mingxi Wan
Intracranial blood pressure can directly reflect the status of blood vessels in real time. However, it can only be estimated invasively using a microcatheter during craniotomy. Subharmonic-aided pressure estimation (SHAPE) is a promising technique for estimating cardiac pressures but mainly uses Sonazoid, whereas SHAPE using SonoVue is still in the early stages of development. The aim of this study was to optimize transcranial SHAPE using SonoVue by investigating the relationship between subharmonic signals and middle cerebral artery pressure (MCAP) (20–160 mmHg) in vitro . We examined the effect of acoustic output levels (peak negative pressures (PNPs) of 238, 346, and 454 kPa), time in suspension (time from reconstituting the suspension to extracting it: 0–30 min), and exposure to gas-equilibrated saline (3 min, 1 h, or original gas completely replaced by air) on the subharmonic-pressure relationship. A mean subharmonic amplitude over a 0.4 MHz bandwidth was extracted using a 5 MHz 12-cycle pulse. A PNP of 346 kPa elicited the best subharmonic sensitivity for assessing hydrostatic pressures up to 0.24 dB/mmHg, possibly because compression-only behavior no longer occurs at this pressure. Moreover, the expansion force is not large enough to offset the effects of hydrostatic pressure. A linear monotonic relationship between the subharmonic amplitude and hydrostatic pressure was only observed for just prepared SonoVue. Excessive exposure to gas-equilibrated saline also affected the subharmonic-pressure relationship. Therefore, just prepared SonoVue should be used, and the duration of the pressure estimation process should be strictly controlled.

6 February 2024 in Ultrasonics
Verified
Journal Article
Closed access
JYJianjun Yu
Jianjun Yu
HGHao Guo
Hao Guo
XQXiaoyang Qiao
Xiaoyang Qiao
LJLiyuan Jiang
Liyuan Jiang
YCYiran Chen
Yiran Chen
MWMingxi Wan
Mingxi Wan

14 January 2024 in Ultrasonics
Verified
Journal Article
Closed access
XQXiaoyang Qiao
Xiaoyang Qiao
RZRuiyan Zhang
Ruiyan Zhang
JYJianjun Yu
Jianjun Yu
YYYadi Yan
Yadi Yan
ABAyache Bouakaz
Ayache Bouakaz
MWMingxi Wan
Mingxi Wan

2 December 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YYYadi Yan
Yadi Yan
YLYingying Liu
Yingying Liu
XQXiaoyang Qiao
Xiaoyang Qiao
DWDiya Wang
Diya Wang
LXLei Xu
Lei Xu
MWMingxi Wan
Mingxi Wan
Ultrasound images have inherent disadvantages such as blurred details and high noise, and super-resolution reconstruction will improve the image quality and help for more accurate clinical diagnosis. In order to solve the problem that it is difficult to capture local feature information and lose important information in the process of down-sampling, we propose a super-resolution (SR) reconstruction method of ultrasound single image based on U-Residual Local Window Transformer (U-RLWT). Specifically, we construct a network encoder module that fuses two residual swim transformer blocks and a down-sampling layer. It obtains more low-frequency information of ultrasound images by improving the receptive field of the feature extractor. Then, to combine the feature information between the layers and recover the feature map, the decoder module was constructed by using the residual swim transformer block and the up-sampling layer. Finally, the reconstruction module was designed with convolution and Pixel-shuffle network to realize the super-resolution reconstruction of ultrasound single images. Experimental results show that, compared with the advanced reconstruction methods, the proposed method can reconstruct the better results compared with the ground truth. When applied to larynx ultrasound images and PICMUS datasets, it achieves the highest PSNR and SSIM on the scale factors of x2 and x4.