23 December 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Intracranial blood pressure can directly reflect the status of blood vessels in real time. However, it can only be estimated invasively using a microcatheter during craniotomy. Subharmonic-aided pressure estimation (SHAPE) is a promising technique for estimating cardiac pressures but mainly uses Sonazoid, whereas SHAPE using SonoVue is still in the early stages of development. The aim of this study was to optimize transcranial SHAPE using SonoVue by investigating the relationship between subharmonic signals and middle cerebral artery pressure (MCAP) (20–160 mmHg) in vitro . We examined the effect of acoustic output levels (peak negative pressures (PNPs) of 238, 346, and 454 kPa), time in suspension (time from reconstituting the suspension to extracting it: 0–30 min), and exposure to gas-equilibrated saline (3 min, 1 h, or original gas completely replaced by air) on the subharmonic-pressure relationship. A mean subharmonic amplitude over a 0.4 MHz bandwidth was extracted using a 5 MHz 12-cycle pulse. A PNP of 346 kPa elicited the best subharmonic sensitivity for assessing hydrostatic pressures up to 0.24 dB/mmHg, possibly because compression-only behavior no longer occurs at this pressure. Moreover, the expansion force is not large enough to offset the effects of hydrostatic pressure. A linear monotonic relationship between the subharmonic amplitude and hydrostatic pressure was only observed for just prepared SonoVue. Excessive exposure to gas-equilibrated saline also affected the subharmonic-pressure relationship. Therefore, just prepared SonoVue should be used, and the duration of the pressure estimation process should be strictly controlled.
6 February 2024 in Ultrasonics
14 January 2024 in Ultrasonics
2 December 2024 in IEEE Transactions on Instrumentation and Measurement
Ultrasound images have inherent disadvantages such as blurred details and high noise, and super-resolution reconstruction will improve the image quality and help for more accurate clinical diagnosis. In order to solve the problem that it is difficult to capture local feature information and lose important information in the process of down-sampling, we propose a super-resolution (SR) reconstruction method of ultrasound single image based on U-Residual Local Window Transformer (U-RLWT). Specifically, we construct a network encoder module that fuses two residual swim transformer blocks and a down-sampling layer. It obtains more low-frequency information of ultrasound images by improving the receptive field of the feature extractor. Then, to combine the feature information between the layers and recover the feature map, the decoder module was constructed by using the residual swim transformer block and the up-sampling layer. Finally, the reconstruction module was designed with convolution and Pixel-shuffle network to realize the super-resolution reconstruction of ultrasound single images. Experimental results show that, compared with the advanced reconstruction methods, the proposed method can reconstruct the better results compared with the ground truth. When applied to larynx ultrasound images and PICMUS datasets, it achieves the highest PSNR and SSIM on the scale factors of x2 and x4.