Context: Lower extremity bone stress injuries (BSI) place a significant burden on the health and readiness of the US Armed Forces. Objective: To determine if pre-injury baseline performance on an expanded and automated 22-item version of the Landing Error Scoring System (LESS-22) is associated with the incidence of BSI in a military training population. Design: Prospective cohort study. Setting: US Military Academy at West Point Participants: 2,235 (510 females, 22.8%) incoming cadets Main outcome measures: Multivariable Poisson regression models were used to produce adjusted incidence rate ratios (IRR) to quantify the association between pre-injury LESS scores and BSI incidence rate during follow-up, adjusted for pertinent risk factors. Risk factors were included as covariates in the final model if the 95% confidence interval (95% CI) for the crude IRR did not contain 1.00. Results: A total of 54 BSI occurred during the study period, resulting in an overall incidence rate of 0.07 BSI per 1,000 person-days (95% CI: 0.05, 0.09). The mean number of exposure days was 345.4 (SD 61.12, range 3–368). The final model was adjusted for sex and BMI and yielded an adjusted IRR for LESS-22 score of 1.06 (95% CI: 1.002, 1.13; p=0.04), indicating that each additional LESS error documented at baseline was associated with a 6.0% increase in the incidence rate of BSI during the follow-up period. In addition, six individual LESS-22 items, including two newly added items, were significantly associated with BSI incidence. Conclusions: This study provides evidence that performance on the expanded and automated version of the LESS is associated with BSI incidence in a military training population. These results suggest that the automated LESS-22 may be a scalable solution for screening military training populations for BSI risk.
1 December 2021 in Archives of Physical Medicine and Rehabilitation
Purpose: To determine the biomechanical effects of a lateral hinge screw on postoperative fracture after medial closing wedge distal femoral osteotomy (MCWDFO). It was hypothesized that adding a lateral hinge screw would significantly increase the failure strength of the hinge. Methods: Twelve Sawbone femurs were used for the study. A biplanar cut was made, a protective lateral hinge pin was placed, and a 5 mm‐closing wedge osteotomy was performed in each specimen. After osteotomy, the hinge pin was removed in six specimens, and in the remaining six specimens, the hinge pin was replaced with a lateral hinge screw. A varus load was then applied utilizing a load frame in a single load‐to‐failure test. Failure was defined as the point just before a substantial drop in the force versus displacement curve. Nonparametric Wilcoxon rank‐sum test was performed to compare maximum load and stiffness between the hinge screw and no hinge screw groups with p < 0.05 considered the threshold of statistical significance. Results: The maximum load to failure was significantly higher in the hinge screw group versus the control group, 440 ± 70 N versus 256 ± 107 N (mean ± standard deviation), respectively. Load to failure was 72% higher in the hinge screw group versus the no hinge screw group. No significant difference in stiffness was found between the groups. Conclusion: Using a Sawbone model, the current data showed that placement of a lateral hinge screw significantly increased resistance to varus stress following MCWDFO compared with a construct having no screw. Additionally, no significant difference in stiffness was observed between the group with the hinge screw and the group without the screw. Further investigation should assess the clinical benefit of a hinge screw in reducing surgical morbidity during the postoperative period for patients undergoing a distal femoral osteotomy. Level of Evidence: N/A.