5 June 2019 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
MLMario H. Lobao
Mario H. Lobao
RCR. Bruce Canham
R. Bruce Canham
RMRoshan T. Melvani
Roshan T. Melvani
JAJoseph A. Abboud
Joseph A. Abboud
BPBrent G. Parks
Brent G. Parks
AMAnand Murthi
Anand Murthi
Background: A subacromial balloon spacer is an option to treat irreparable rotator cuff tears. We hypothesized that the balloon would restore glenohumeral contact pressure, the acromion-humeral interval, and deltoid load to intact values after a simulated irreparable supraspinatus tear in a cadaveric model. Methods: Fourteen cadaveric shoulders (mean age at the time of death, 67.9 years) were tested using a custom test frame. In this frame, glenohumeral contact pressure, the acromion-humeral interval, and deltoid load were measured using a digital sensor, a MicroScribe, and a spring scale, respectively. Test conditions included the intact shoulder, a small supraspinatus tear, supraspinatus repair, repair plus balloon, an irreparable supraspinatus tear (rotator cable-insufficient), and an irreparable tear plus balloon. Load was applied in a simulated neutral arm position (balanced) and active shoulder abduction (unbalanced). Results: When the balloon was inflated over the irreparable supraspinatus tear in the balanced condition, glenohumeral contact pressure increased by 122% (p = 0.006) compared with that for the irreparable tear at 0° of abduction and by 94% (p = 0.046) at 60°. In the unbalanced condition, pressure decreased in the irreparable tear condition after the balloon was inflated, restoring pressure to close to that in the intact state. The balloon did not restore glenohumeral contact area to that in the intact shoulder in either the balanced or the unbalanced condition. The irreparable tear displaced the humeral head superiorly in the unbalanced condition, decreasing the acromion-humeral interval. The balloon moved the head inferiorly by a mean (and standard error of the mean) of 6.2 ± 1.3 mm (p < 0.001) at 0° of abduction, 4.4 ± 1.3 mm (p < 0.001) at 30°, and 3.0 ± 0.8 mm (p < 0.001) at 60°. The balloon increased the deltoid load after an irreparable tear by 8.2% (p = 0.022) at 0°, 12.6% (p = 0.002) at 30°, and 11.1% (p = 0.008) at 60°. Conclusions: In a cadaveric model of an irreparable supraspinatus tear, a balloon spacer restored intact-state glenohumeral contact pressures at most abduction angles, lowered the humeral head, and increased deltoid load at postoperative time 0. Clinical Relevance: This study supports further investigation of the balloon spacer in comparative clinical studies of surgical options for irreparable rotator cuff tears, with clinically relevant evaluation measures and observation periods.

21 June 2023 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
MLMario H. Lobao
Mario H. Lobao
PAPooyan Abbasi
Pooyan Abbasi
SSSteven J. Svoboda
Steven J. Svoboda

1 December 2020 in Journal of the American Academy of Orthopaedic Surgeons
Verified
Journal Article
Closed access
MWMelissa A. Wright
Melissa A. Wright
MLMario H. Lobao
Mario H. Lobao
PAPooyan Abbasi
Pooyan Abbasi
BPBrent G. Parks
Brent G. Parks
KMKatherine L. Mistretta
Katherine L. Mistretta
AMAnand Murthi
Anand Murthi
Introduction: There is little biomechanical evidence to support the traditional guideline that 45° represents acceptable proximal humerus deformity. We evaluated glenohumeral contact pressure (GP) and area, subacromial contact pressure, and joint abduction to assess biomechanical changes with different proximal humerus deformities. Methods: Fifteen fresh-frozen cadaver shoulders were used. Intact specimens were tested on a custom dynamic shoulder frame. Subsequently, a surgical neck fracture was made in each specimen and fixed using a custom dual hinge plate for fixation of 15°, 30°, and 45° deformities in varus, valgus, antecurvatum, retrocurvatum, and combined varus-antecurvatum and valgus-retrocurvatum. Specimens were then retested. Results: Compared with the intact state, GP was markedly lower with all levels of varus and varus-antecurvatum deformity. Valgus and combined valgus-retrocurvatum deformity of 45° led to notable increases in GP compared with the intact state. Varus deformities of 30° and 45° caused significant increases in subacromial pressures and limited abduction markedly from 60° to 54.2° and 44.6° (P < 0.001). Discussion: Varus and antecurvatum proximal humerus deformities as small as 15° were associated with notable alterations in glenohumeral joint mechanics. With valgus and retrocurvatum deformity, statistically significant joint alterations occurred only at higher deformity levels.

17 September 2025 in JSES International
Verified
Journal Article
Open access
CVCameron Vauclin
Cameron Vauclin
ASAaron Sheppard
Aaron Sheppard
PMPatrick Massey
Patrick Massey
JAJaxon Adkins
Jaxon Adkins
MCMark Callanan
Mark Callanan
RBR. Shane Barton
R. Shane Barton
Significant proximal humerus bone loss poses a challenge on the outcomes of traditional reverse shoulder arthroplasty implants. Modular Segmental Megaprosthesis (MSM) offers a potential solution to shoulder reconstruction without the need for allograft. However, clinical outcomes of MSM are restricted to case reports and small case series with limited follow-up. An Institutional Joint Registry Database was used to identify revision shoulder arthroplasty patients using MSM. A retrospective review evaluated implant survivorship, pain relief and functional outcomes at a minimum of 2-year follow-up. Between 2014 and 2022, a total of 28 patients with significant proximal humerus bone loss who underwent revision shoulder arthroplasty reconstruction using MSM were included in this study. At a minimum of 2-year follow-up, the MSM implant survivorship was 85.7% (24 out of 28). Pain level decreased from 7 out of 10 preoperatively to 2 at the 2-year follow-up mark (P = .001). Range of motion also improved: elevation increased from 46° preoperatively to 102° postoperatively (P = .004); abduction improved from 33° to 92° (P = 0.002); and external rotation increased from 13° to 31°(P = .036), respectively. Constant Score increased from 12.9 preoperatively to 69.6 at 2-years after surgery (P = .008). The American Shoulder and Elbow Surgeons score increased from 7.4 to 77.2 (P = .008), and Simple Shoulder Test (SST) increased from 11.1 to 68.1%, respectively (P = .008). The MSM presented a good 2-year survivorship. It demonstrated significant improvement in pain and function in patients with proximal humerus bone loss that underwent arthroplasty revision. These findings support the use of MSM as a salvage procedure in complex shoulder reconstructions.