21 April 2020 in IEEE Transactions on Power Electronics
Digital control delay is studied as one of the leading factors causing instability in grid-tied voltage source inverter (VSI) systems. However, how this delay affects the output impedance of the VSI, and how the resulting impedance change further influences the stability of the system are still not clear. This paper, for the first time, thoroughly analyzes the impact of delay on the dq-frame output impedance of the VSI operating in both the single current loop control mode and dual-loop control mode. It is observed that when delay is considered, a distinct magnitude drop and phase rise phenomenon at the high-frequency area of the impedance always exists, which is named the “impedance trough”. By investigating the dq-frame output impedance of the VSI, the origin of the impedance trough, and its analytical relationships with the current loop dynamics, voltage loop dynamics and delay are obtained. Meanwhile, influences of the impedance trough on the stability of the grid-tied VSI system are both assessed through d-d channel impedance matching and Generalized Nyquist Criterion (GNC). It is verified that the root cause of high-frequency oscillations is the impedance mismatch between the grid and the VSI due to impedance trough. Finally, experimental results verify the analysis.
11 November 2024 in IEEE Transactions on Power Electronics
Data-driven approach is promising for predicting impedance profile of grid-connected voltage source converters (VSCs) under a wide range of operating points (OPs). However, the conventional approaches rely on a one-to-one mapping between operating points and impedance profiles, which, as pointed out in this article, can be invalid for multiconverter systems. To tackle this challenge, this article proposes a stacked-autoencoder-based machine learning framework for the impedance profile predication of grid-connected VSCs, together with its detailed design guidelines. The proposed method uses features, instead of OPs, to characterize impedance profiles, and hence, it is scalable for multiconverter systems. Another benefit of the proposed method is the capability of predicting VSC impedance profiles at unstable OPs of the grid-VSC system. Such prediction can be realized solely based on data collected during stable operation, showcasing its potential for rapid online state estimation. Experiments on both single-VSC and multi-VSC systems validate the effectiveness of the proposed method.