Roland Steiner

Roland Steiner

Auto-generated profile, based on publicly available information

Roland Steiner

Department of Physics, Universität Basel, Klingelbergstrasse 82, Basel, Basel-Stadt, 4056, SWITZERLAND

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2022 in Nuclear Fusion
Verified
Journal Article
Open access
KSKunal Soni
Kunal Soni
SISanthosh Iyyakkunnel
Santhosh Iyyakkunnel
RSRoland Steiner
Roland Steiner
RARodrigo Antunes
Rodrigo Antunes
LMLucas Moser
Lucas Moser
EMErnst Meyer
Ernst Meyer
The first mirror (FM) cleaning operations in ITER are expected to be executed in the presence of a ∼ 3 T magnetic field. In the RF plasma cleaning configuration, this would have a significant influence on the plasma properties, ion energy, angle of incidence as well as flux spatial distribution. To this end, RF discharges were excited in an ITER-sized mock-up of a first mirror unit (FMU) consisting of a powered first mirror M1 and a grounded second mirror M2 placed in a homogeneous 3 T magnetic field. The plasma discharge was confined in a beam extending in the direction of the magnetic field, consequently wetting a limited portion of the FMU walls. In the DC-decoupled scheme (without λ/4 filter), this considerably influenced the self-bias voltage V DC that develops on M1. Changing the angle α between M1 normal and magnetic field, modified the plasma wetted wall area A g and the resulting V DC varied by over two orders of magnitude. Plasma exposure experiments were also done in the DC-coupled scheme (with λ/4 filter), wherein the angle and wetted surface determined the area of wall sputtered. Increasing α led to an increase in the sputtered wall area A g, and consequently the wall deposition on grounded M2. However, in all the cases M1 was entirely clean with the exception of edge deposits in some. In contrast, both M1 and M2 are coated with wall deposits in the absence of a magnetic field and a similar plasma exposure. The results show that plasma cleaning with λ/4 filter in a 3 T magnetic field at ITER could potentially prevent the parasitic wall deposition on FMs. The results also highlight the importance of FM orientation in the magnetic field and the wetted area in the plasma cleaning in both the DC-coupled and decoupled schemes within the ITER diagnostic systems.

11 February 2021 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Open access
PDF file
KSKunal Soni
Kunal Soni
LMLucas Moser
Lucas Moser
ZDZoltán Donkó
Zoltán Donkó
PHPeter Hartmann
Peter Hartmann
IKIhor Korolov
Ihor Korolov
EMErnst Meyer
Ernst Meyer
We present a combined experimental and numerical investigation of the plasma properties in an asymmetric capacitively coupled radio frequency plasma source using argon discharge. Besides driving the system in the conventional way, which results in a high negative self-bias voltage V DC due to the asymmetric configuration, we also connect a ‘quarter-wavelength filter’ to the powered electrode, which lifts its DC potential to zero. At the powered side of the plasma, we employ electrodes with conducting and insulating surfaces, as well as electrodes combining both in different proportions (‘hybrid electrodes’). Measurements are carried out for the plasma potential, the electron density and temperature in the bulk plasma, as well as for the flux-energy distribution of the ions at the grounded surface of the system. The nature of the surface of the powered electrode as well as the presence of the quarter-wavelength filter are found to highly influence the plasma potential, V p ‾ . For the electrode with a conducting surface V p ‾ ∼ 20 V and ∼150 V are found in the absence and the presence of the filter, respectively. For the electrode with an insulating surface, the self-bias voltage builds up directly at the plasma interface, thus the filter has no effect and a plasma potential of ∼20 V is found. For the electrodes with different conducting/insulating proportions of their surface, V p ‾ ranges between the above values. Particle-in-Cell/Monte Carlo Collisions calculations for identical conditions with hybrid electrodes predict double-peaked ion energy distribution at the powered electrode with peaks corresponding to e V p ‾ and e ( V p ‾ − V DC ) along with a lowering of the plasma potential (whencompared to wholly conducting electrode), a trend that is observed experimentally. These studies are of great importance for the application of similar plasma sources with in-situ cleaning of mirrors in fusion devices and the results can be extended to a variety of plasma processing applications.

5 January 2015 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
BEBaran Eren
Baran Eren
WFWangyang Fu
Wangyang Fu
LMLaurent Marot
Laurent Marot
MCMichel Calame
Michel Calame
RSRoland Steiner
Roland Steiner
EMErnst Meyer
Ernst Meyer
In this work, the optical response of graphene to hydrogen plasma treatment is investigated with spectroscopic ellipsometry measurements. Although the electronic transport properties and Raman spectrum of graphene change after plasma hydrogenation, ellipsometric parameters of the Si/SiO2/graphene tri-layer system do not change. This is attributed to plasma hydrogenated graphene still being electrically conductive, since the light absorption of conducting 2D materials does not depend on the electronic band structure. A change in the light transmission can only be observed when higher energy hydrogen ions (30 eV) are employed, which chemically sputter the graphene layer. An optical contrast is still apparent after sputtering due to the remaining traces of graphene and hydrocarbons on the surface. In brief, plasma treatment does not change the light transmission of graphene; and when it does, this is actually due to plasma damage rather than plasma hydrogenation.

1 September 2023 in Plasma Sources Science and Technology
Verified
Journal Article
Open access
PDF file
PHPaul Hiret
Paul Hiret
KSKunal Soni
Kunal Soni
AMAnil Cherukulappurath Mana
Anil Cherukulappurath Mana
EFEric Faudot
Eric Faudot
LMLucas Moser
Lucas Moser
EMErnst Meyer
Ernst Meyer
The surface erosion of biased electrodes immersed in a radio frequency (RF) plasma was investigated in oblique magnetic fields ranging from 0.1 T to 3.5 T. The plasma potential and density in the vicinity of the biased electrode have been measured using an RF-compensated cylindrical Langmuir probe moved by a three-dimensional motorised arm in the ALINE facility at 0.1 T. The erosion profiles were determined for different gases (argon and helium), magnetic field strength and plasma volume for the same electrode surface area at an angle of 5∘ with the magnetic field in three different experimental geometries. The radial electric field (perpendicular to the magnetic field) in the plasma column has been deduced from plasma potential measurements. This radial field makes the ions converge to the core of the plasma column at grazing angles ( < 30∘) and is reversed at larger angles. The ion flux on the sample increases with the magnetic field magnitude leading to a strong erosion inhomogeneity. At lower plasma volume, the erosion rate is sensitively enhanced. Local redeposition was identified using x-ray photoelectron spectroscopy on the surfaces exhibiting preferential deposition directions. Finally, the asymmetric erosion patterns obtained from a molybdenum layer etching are explained by the similar asymmetric density maps obtained with the probe and by the E → × B → drift and the local sheath acceleration.

22 October 2021 in Nuclear Fusion
Verified
Journal Article
Closed access
PDF file
KSKunal Soni
Kunal Soni
RSRoland Steiner
Roland Steiner
RARodrigo Antunes
Rodrigo Antunes
LMLucas Moser
Lucas Moser
PSPavel Shigin
Pavel Shigin
EMErnst Meyer
Ernst Meyer

1 July 2022 in Plasma Sources Science and Technology
Verified
Journal Article
Open access
KSKunal Soni
Kunal Soni
RARodrigo Antunes
Rodrigo Antunes
RSRoland Steiner
Roland Steiner
LMLucas Moser
Lucas Moser
LMLaurent Marot
Laurent Marot
EMErnst Meyer
Ernst Meyer
We present an experimental investigation of the ion flux–energy distribution functions (IFEDFs) obtained across grounded grids in an asymmetric capacitively coupled RF source using a helium discharge. The powered electrode in the RF source is DC-grounded via a λ/4 filter, which lifts its DC potential to zero. Grids of different dimensions (hole width, thickness, and geometric transparency) were used to confine the plasma, while the IFEDF of the ion beam departing the grid and reaching the reactor walls was studied using a retarding field energy analyser. The IFEDF obtained was double-peaked, indicating the presence of fast ions arriving from the plasma source, and cold ions generated upon charge exchange collisions between the fast ions and neutrals. The flux, as well as the peak energies of the two ion groups, depended significantly on the process parameters: RF power, He pressure, the distance between grids and walls, and the dimensions of the grids. The results indicate that confining plasma with grids can reduce the ion flux at the walls by over 60%, significantly lowering the wall sputtering rate. This was confirmed with a dedicated long-exposure plasma discharge with a gridded plasma reactor, wherein less than 1 nm of Cu deposition was found on the DC-grounded powered electrode, and the surface reflectivity was preserved to pristine values. In contrast, a similar experiment in a gridless reactor resulted in Cu deposition of 35 nm with a drastic drop in surface reflectivity. These studies are of great importance for the application of similar RF plasma sources with in-situ cleaning of diagnostic mirrors in fusion devices, as well as in a variety of plasma processing applications.