Jie Wu

Jie Wu

Auto-generated profile, based on publicly available information

Jie Wu

Affiliation The College of Information, Mechanical and Electrical Engineering, Shanghai Normal University, Shanghai, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2020 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
JWJie Wu
Jie Wu
CLChuanjiang Li
Chuanjiang Li
For a VSC-HVDC transmission system based on a hybrid topology converter of full-bridge and half-bridge, a kind of virtual synchronous generator (VSG) control strategy which can be applied to modular multilevel converter (MMC) grid-connected structure was researched and proposed. First, based on the conventional VSG control strategy, the energy stored in the equivalent capacitor of MMC power module was used to imitate the rotor inertia of synchronous generator. The characteristics of generator can be simulated during transient frequency fluctuations and it can help relieve the power fluctuations. Secondly, with respect to the structural characteristics of the direct grid connection through the reactor on the AC side of the MMC, which is unlike the microgrid inverter, there are no additional filter capacitors. So, the existing commonly used VSG control strategy of the microgrid inverter and double-closed-loop structure composed of filter capacitor voltage and AC current cannot be directly applied. For this, a method where the given values of inner current loop are calculated by grid impedance matrix was used. So, a double-closed-loop control structure composed of a power outer loop based on VSG control and a current inner loop is obtained. It can effectively improve the current control capability during the transient process. Finally, a hybrid MMC simulation model was built based on PSCAD to verify the correctness and effectiveness of the proposed methods.

25 March 2022 in IEEE Access
Verified
Journal Article
Open access
JWJie Wu
Jie Wu
CLChuanjiang Li
Chuanjiang Li
The converter valve is the core equipment of the DC distribution systems. This paper proposes an autonomous control strategy for grid-connected and islanded operation of hybrid topology modular multilevel converter (MMC). The overall control structure is designed, including the outer loop for autonomous control and the inner current loop. Firstly, for the outer loop, it is proposed to use the equivalent capacitance storage energy of MMC power module to simulate the inertia of synchronous generator rotor to achieve the purpose of buffer power fluctuation. So, the outer loop provides system inertia. Second, the inner loop is designed for current tracking control and suppresses transient fault current effectively. It is proposed that the current inner loop reference value can be directly calculated through the grid-connected impedance matrix and voltage across it. And the small signal model of autonomous control for a hybrid MMC is established. Then the influence of the proposed control structure and control parameters on the impedance characteristics of the system is analyzed in detail. Finally, a hybrid MMC simulation model for DC distribution system is built based on PSCAD, simulating island operation, grid-connected operation mode and transient faults respectively for verifying the proposed strategies.

30 March 2021 in International Journal of Green Energy
Verified
Journal Article
Closed access
XYXiaoli Yu
Xiaoli Yu
XYXiaonan Yu
Xiaonan Yu
Zhi LiZhi Li
Zhi Li
RHRui Huang
Rui Huang
Lei WangLei Wang
Lei Wang
JWJie Wu
Jie Wu
The time-dependent energy demand of energy islands may frequently change the operating condition of diesel generator (DG), leading to diesel engine operating under off-design conditions with low efficiency. In order to make the DG operate under efficient conditions and balance the mismatch of energy supply and demand in time, a novel hybrid power generation system integrated DG with compressed heat energy storage (CHEST) using sensible and latent thermal energy storage is proposed in this study. The overall efficiency of the proposed system could be further improved due to the waste heat recovery of exhaust and cooling water. Firstly, a parametric analysis of the CHEST unit is conducted to select optimal parameters and conditions for the CHEST unit. Then a comparative analysis between the traditional DG system and the proposed DG-CHEST coupling system with three operating strategies is carried out. Results indicate that Strategy A, B, and C could save fuel of 45.48 kg (17.74%), 44.22 kg (16.19%), and 38.89 kg (14.23%) a day, corresponding to the overall efficiency of 28.02%, 27.83%, and 26.22%, respectively, while it is only 20.89% for the conventional DG system. The comparative results among the three strategies show that the discharged power index (DPI) and discharged fraction (DF) decrease with the increase of control level of load factor.

9 December 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JWJie Wu
Jie Wu
SYShiyi Yin
Shiyi Yin
CLChuanjiang Li
Chuanjiang Li
QZQiaozhen Zhang
Qiaozhen Zhang
A new virtual synchronous generator (VSG) control strategy was researched and proposed for a VSC-HVDC (High Voltage Direct Current Based on Voltage Source Converter) transmission system. It can be applied to half-bridge or full-half-bridge hybrid topology modular multi-level converter (MMC) to improve the stability and reliability of the system. First, it is proposed that the energy stored in the equivalent capacitor of MMC power module was used to imitate the rotor inertial of synchronous generator. It can buffer transient power fluctuations and synchronize autonomously with the grid. Then the impedance characteristics of the proposed control method have been deduced and analyzed. The results show that the VSG control loop mainly improves the low frequency characteristics of the converter. Secondly, the ability to suppress transient fault current is weak. So, a method, that the given values of inner current loop are calculated by grid impedance matrix, was used. A double closed loop control structure composed by a power outer loop based on VSG control and a current inner loop is obtained. The simulation results show that it can effectively improve the current control capability during the transient process for systems with a 1:2 ratio of converter capacity to grid capacity (The grid short-circuit capacity is 60MW and the MMC is 30 MW). Finally, a hybrid MMC simulation model was built based on PSCAD and the steady-state and transient fault ride-through simulations were performed. The power adjustment time of MMC under the proposed VSG control is about 1s, while the adjustment time under the conventional control strategy is greater than 4s.