1 February 2004 in Spectrochimica Acta Part B: Atomic Spectroscopy
1 January 1998 in Journal of Analytical Atomic Spectrometry
The spatial profile from an XeCl excimer laser was modified using a simple two-lenses telescope to generate a flat energy-profile beam that impinged a layered sample (a Zn-coated steel) without beam conditioning. The irradiance obtained (about 107 W cm–2) was high enough to vaporize the target, to cause plasma formation and to allow atomic emission spectrometry with acceptable signal-to-noise ratio. Modification in beam energy distribution resulted in flat ablated profiles and improved depth-resolution up to the few nm pulse–1 range was attained. The net intensity areas were transformed into normalized values leading to plots in excellent agreement with those provided by commercial depth-resolved analysis instruments.
3 September 1999 in Analytical Chemistry
1 January 1997 in Journal of Analytical Atomic Spectrometry
The capability of laser-induced breakdown spectrometry (LIBS) to resolve complex depth profiles is demonstrated. Electrolytically deposited brass samples were analyzed by monitoring the emission corresponding to Cr (357.8 nm), Ni (341.4 nm), Cu (327.4 nm) and Zn (334.5 nm). The nominal thickness of the layers was known, which permitted an estimate of the ablated mass in the range between 150 and 500 nm per pulse depending on the matrix and laser irradiance. Laser irradiance was varied by defocusing, and its effect on the depth-resolution of LIBS was tested. For comparison purposes, a commercial zinc-coated steel was also studied by following the Zn and Fe emission intensity depth profiles with a commercial glow-discharge optical emission spectrometry system to obtain information on the exact location of the Zn–Fe interface (12 µm). The ablation rate in terms of ablated mass per pulse was found to be at the ng per pulse level and depended on the laser pulse irradiance.
18 December 1998 in Surface and Interface Analysis
1 July 2000 in Applied Spectroscopy
The combination of angle-resolved laser ablation with the use of a collimated beam is presented as a new approach to increase the depth-resolved capabilities of laser-induced breakdown spectrometry (LIBS). The effect of beam conditioning and the reduction of the effective sampling depth due to the angular dependence of laser ablation allow ablation rates lower than 2 nm/pulse for coated materials (Sn-coated steels and Cr-coated samples). Spectral information is obtained on a single-laser-shot basis. The effect of incidence angle has been examined from differentiated emission profiles, demonstrating the beneficial effect of working at incidence different from normal. A compromise between depth resolution and emission signal must be found at large angles due to the lower irradiance resulting from the increase in beam size at the interface for large angles of incidence. A comparison of the proposed approach with the analysis provided by a commercial glow-discharge device [glow discharge optical emission spectroscopy (GD-OES)] demonstrated quite satisfactory results.