9 November 2005 in Journal of Analytical Atomic Spectrometry
The detection and characterization of energetic materials at distances up to 45 m using stand-off laser induced breakdown spectroscopy (LIBS) has been demonstrated. A field-portable open-path LIB spectrometer working under a coaxial configuration was used. A preliminary study allowed choosing a single-pulse laser source over a double-pulse system as the most suitable source for the stand-off analysis of organic samples. The C2 Swan system, as well as the hydrogen, oxygen and nitrogen emission intensity ratios were the necessary parameters to identify the analyte as an organic explosive, organic non-explosive and non-organic samples. O/N intensity ratios of 2.9 and 2.16 with relative standard deviations of 4.03% and 8.36% were obtained for 2,4-dinitrotoluene and aluminium samples, respectively. A field test with known samples and a blind test were carried out at a distance of 30 m from the sample. Identification of energetic compounds in such conditions resulted in 19 correct results out of 21 samples.
14 April 2005 in Journal of Analytical Atomic Spectrometry
The development of a compact laser induced breakdown spectroscopy (LIBS) system increases the possibilities of applying the technique in industrial arenas, field applications and process monitoring. Significant progress has been achieved in miniaturization of optical detectors and lasers, allowing portable, low-cost LIBS equipment to be devised. Conventional lasers for LIBS, like actively Q-switched Nd:YAG lasers are limited by their bulkiness, the need for a cooling system and high power consumption. The use of a miniature solid state microchip laser overcomes these drawbacks and offers further advantages of good beam quality, high pulse repetition frequency and less damage to target. In this work we studied the quantification of elemental composition of low alloy steel samples using a higher power microchip (“powerchip”) laser. The possibility of real time, in situ quantification of such materials by powerchip LIBS enhances the applicability of the technique to process monitoring in the steelmaking industry. The performance of the LIBS technique based on a powerchip laser and a portable non-intensified, non-gated detector for elemental quantification is evaluated and compared to that obtained using an intensified detector. Calibrations were achieved for Cr, Mo, Ni, Mn and Si with linear regression coefficients between 0.98–0.99 and limits of detection below 100 ppm in most cases.
1 January 1999 in Journal of Analytical Atomic Spectrometry
Laser-induced breakdown spectrometry has been evaluated at high temperatures for stainless steel samples. A Q-switched Nd:YAG laser operating at 1064 nm was used to create a microplasma on an AISI 304L stainless steel sample placed inside a laboratory oven. The steel sample was 51.5 cm away from the focusing lens. The temperature of the samples ranged from 25 to 1200 °C. The plasma light was collected by means of a fiber optic bundle, spectrally resolved and then detected by a CCD camera. The effects of sample temperature in the formation of a laser-induced plasma have been studied in terms of its spectral features as well as the morphology of the ablated craters in air at atmospheric pressure. A noticeable dependence of signal emission intensity on sample temperature has been found. Depth profiling of stainless steel samples for several temperature conditions was performed. Results have revealed changes in the superficial composition at temperatures above 600 °C due to the formation of a slag layer of variable thickness, mainly composed of chromium, iron and manganese oxides.
1 January 1998 in Journal of Analytical Atomic Spectrometry
The spatial profile from an XeCl excimer laser was modified using a simple two-lenses telescope to generate a flat energy-profile beam that impinged a layered sample (a Zn-coated steel) without beam conditioning. The irradiance obtained (about 107 W cm–2) was high enough to vaporize the target, to cause plasma formation and to allow atomic emission spectrometry with acceptable signal-to-noise ratio. Modification in beam energy distribution resulted in flat ablated profiles and improved depth-resolution up to the few nm pulse–1 range was attained. The net intensity areas were transformed into normalized values leading to plots in excellent agreement with those provided by commercial depth-resolved analysis instruments.
1 September 2004 in Spectrochimica Acta Part B: Atomic Spectroscopy
1 March 2002 in Spectrochimica Acta Part B: Atomic Spectroscopy