Nathan Angelo Lecaros Yap

Nathan Angelo Lecaros Yap

Auto-generated profile, based on publicly available information

Nathan Angelo Lecaros Yap

Centre for Cardiovascular Medicine and Devices, William Harvey Research Institute, Queen Mary University of London, London, UK; Department of Cardiology, Barts Health NHS Trust, London, UK

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in The Anatolian Journal of Cardiology
Verified
Journal Article
Open access
EEEmrah Erdogan
Emrah Erdogan
LULondon- Uk
London- Uk
VTVan- Turkey
Van- Turkey
ZLZheng Li
Zheng Li
YZYong-Xiang Zhu
Yong-Xiang Zhu
YZYao-Jun Zhang
Yao-Jun Zhang
To investigate the safety and efficacy of a percutaneous revascularization strategy that is based on the use of drug-coated balloon for the treatment of patients with acute coronary syndrome and de novo Medina type 0,1,0 or 0,0,1 left main stem bifurcation lesions. : In this multicenter, prospective, proof-of-concept study, patients fulfilling the above criteria were enrolled and received treatment with drug-coated balloon combined with provisional drug-eluting stent implantation in the proximal major branches of the left main stem. Patients who declined this revascularization approach were treated with drug-eluting stent implantation 1-2 mm distally to the left anterior descending or left circumflex artery ostium followed by drug-coated balloon therapy for the ostial disease. The primary endpoint of the study was the calculation of percent diameter stenosis on quantitative coronary angiography post-procedure as well as event rate at 8 months follow-up. A total of 30 patients were enrolled in the study; their mean age was 60.3 ± 7.8 years, while 22 (73.3%) were male. Twenty-two patients were treated only with drug-coated balloon and provisional drug-eluting stent implantation and 8 had drug-eluting stent implantation followed by drug-coated balloon therapy of the ostium of the left main stem major branch. All the procedures were successful with no immediate complications. The percent diameter stenosis of lesion decreased significantly post-procedure from 87.5% (80.0-90.0) to 20% (17.5-30.0), P < .001. During the follow-up period, no major adverse cardiac events were reported. This proof-of-concept study indicates that ostial drug-coated balloon therapy of the left main stem major branches is safe and effective. Larger clinical data and longer follow-up are needed before advocating its regular use in clinical practice.

20 September 2024 in Computers in Biology and Medicine
Verified
Journal Article
Open access
KBKit Mills Bransby
Kit Mills Bransby
RBRetesh Bajaj
Retesh Bajaj
ARAnantharaman Ramasamy
Anantharaman Ramasamy
MÇMurat Çap
Murat Çap
NYNathan Yap
Nathan Yap
QZQianni Zhang
Qianni Zhang
Segmentation of the coronary vessel wall in intravascular ultrasound is a fundamental step in guiding coronary intervention. However, it is an challenging task, even for highly skilled cardiologists, due to image artefacts and shadowed regions caused by calcified plaque, guide wires and vessel side branches. Recently, dense-based neural networks have been applied to this task, however, they often fail to predict anatomically plausible contours in these low-signal areas. We propose a novel methodology called Polygon-based Contour Refiner (POLYCORE) that addresses topological error in dense-based segmentation networks using a relational inductive bias through higher-order connections between vertices to learn anatomically rational contours. Our approach remedies the over-smoothing phenomena common in polygon networks by introducing a new vector field refinement module which enables pixel-level detail to be added in an iterative process. POLYCORE is enhanced with augmented polygon aggregation which we show is more effective than typical dense-based test-time augmentation strategies. We achieve state-of-the-art results on two diverse datasets, observing particular improvements when segmenting the lumen structure and in topologically-challenging regions containing shadow artefacts. Our source code is available here: http://orcid.org/https://github.com/kitbransby/POLYCORE.

22 October 2025 in Journal of Cardiovascular Computed Tomography
Verified
Journal Article
Open access
NYNathan Angelo Lecaros Yap
Nathan Angelo Lecaros Yap
XHXingwei He
Xingwei He
ITIbrahim Halil Tanboga
Ibrahim Halil Tanboga
ARAnantharaman Ramasamy
Anantharaman Ramasamy
Sotiris KyriakouSotiris Kyriakou
Sotiris Kyriakou
Christos BourantasChristos Bourantas
Christos Bourantas
To evaluate the performance of various computed tomography angiography (CTA) reconstruction methods in assessing coronary plaque composition using near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) as the reference standard. Fifteen patients with chronic coronary syndrome underwent CTA and 3-vessel NIRS-IVUS imaging. CTA datasets were reconstructed using a medium-smooth b40f kernel with two slice thicknesses, 0.75 ​mm and 0.50 ​mm, and three strengths of advanced model-based iterative reconstruction (ADMIRE). Plaque components on CTA were classified using fixed and adaptive Hounsfield unit (HU) thresholds while NIRS-IVUS classification employed a deep learning method validated against histology. Matched CTA and NIRS-IVUS images were analyzed to quantify fibrotic tissue (FT), necrotic core (NC), and calcific (Ca) volumes and areas at both segment- and lesion-level. The intraclass correlation coefficient (ICC) and Surface Under the Cumulative Ranking Curve (SUCRA) scores were used to determine the best-performing reconstruction approach. Fifty vessels were included in the final analysis. CTA showed weak correlation with NIRS-IVUS for FT (ICC <0.43), good correlation for Ca (ICC 0.42-0.83), and poor correlation for NC, except when using reconstruction approach ADMIRE 2, 0.50 ​mm slice thickness, and fixed HU cutoffs, which demonstrated moderate correlation for NC (segment-level ICC ​= ​0.67; lesion-level ICC ​= ​0.61). This approach ranked highest on SUCRA plots. CTA reconstruction parameters influence plaque composition analysis. The combination of an intermediate-strength IR, thin slice thickness, and fixed HU cutoffs yields the most accurate tissue characterization compared to NIRS-IVUS as the reference standard.

26 March 2024 in Journal of the Society for Cardiovascular Angiography & Interventions
Verified
Journal Article
Open access
XHXingwei He
Xingwei He
SMSoe Maung
Soe Maung
ARAnantharaman Ramasamy
Anantharaman Ramasamy
MMMohamed O. Mohamed
Mohamed O. Mohamed
RBRetesh Bajaj
Retesh Bajaj
CBChristos V. Bourantas
Christos V. Bourantas
Coronary artery calcium score (CACS) is an established marker of coronary artery disease (CAD) and has been extensively used to stratify risk in asymptomatic individuals. However, the value of CACS in predicting plaque morphology in patients with advanced CAD is less established. The present analysis aims to assess the association between CACS and plaque characteristics detected by near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) imaging in patients with obstructive CAD. Seventy patients with obstructive CAD underwent coronary computed tomography angiography (CTA) and 3-vessel NIRS-IVUS imaging were included in the present analysis. The CTA data were used to measure the CACS in the entire coronary tree and the segments assessed by NIRS-IVUS, and these estimations were associated with the NIRS-IVUS measurements at a patient and segment level. In total, 65 patients (188 segments) completed the study protocol and were included in the analysis. A weak correlation was noted between the CACS, percent atheroma volume (r = 0.271, P = .002), and the calcific burden measured by NIRS-IVUS (r = 0.648, P < .001) at patient-level analysis. Conversely, there was no association between the CACS and the lipid content, or the incidence of high-risk plaques detected by NIRS. Linear regression analysis at the segment level demonstrated an association between the CACS and the total atheroma volume (coefficient, 0.087; 95% CI, 0.024-0.149; P = .008) and the calcific burden (coefficient, 0.117; 95% CI, 0.048-0.186; P = .001), but there was no association between the lipid content or the incidence of high-risk lesions. In patients with obstructive CAD, the CACS is not associated with the lipid content or plaque phenotypes. These findings indicate that the CACS may have a limited value for screening or stratifying cardiovascular risk in symptomatic patients with a high probability of CAD.

23 December 2023 in Journal of Cardiovascular Computed Tomography
Verified
Journal Article
Closed access
MÇMurat Çap
Murat Çap
ARAnantharaman Ramasamy
Anantharaman Ramasamy
RPRamya Parasa
Ramya Parasa
ITIbrahim H. Tanboga
Ibrahim H. Tanboga
SMSoe Maung
Soe Maung
Christos BourantasChristos Bourantas
Christos Bourantas

16 January 2026 in European Heart Journal - Digital Health
Verified
Journal Article
Open access
XHXingwei He
Xingwei He
KBKit Mills Bransby
Kit Mills Bransby
AUAhmet Emir Ulutas
Ahmet Emir Ulutas
TKThamil Kumaran
Thamil Kumaran
NYNathan Angelo Lecaros Yap
Nathan Angelo Lecaros Yap
Christos BourantasChristos Bourantas
Christos Bourantas
Aims: To develop a deep-learning (DL) framework that enables fully automated longitudinal and circumferential co-registration of intravascular ultrasound (IVUS) and optical coherence tomography (OCT) images. Methods and results: Data from 230 patients (714 vessels) with acute myocardial infarction that underwent near-infrared spectroscopy IVUS and OCT imaging in their non-infarct related vessels were analysed. Experts annotated the lumen borders (61 655 IVUS and 62 334 OCT frames), the side branches and the calcific tissue (10 000 IVUS and 10 000 OCT frames each). This information was used to train DL models that extracted these features that were then used by a dynamic time warping algorithm to co-registered longitudinally the IVUS and OCT images. The circumferential registration of IVUS and OCT was performed through a rotation cost matrix and dynamic programming. On a test set of 22 patients (77 vessels), the DL method showed high concordance with the expert analysts for the longitudinal and circumferential co-registration of the two datasets (concordance correlation coefficient >0.99 and >0.90, respectively). The Williams Index was 0.96 for longitudinal and 0.97 for circumferential alignment, indicating a comparable performance of the proposed framework to the analysts. The time needed for the DL pipeline to process imaging data from a vessel was <90 s. Conclusion: A fully automated, DL-based framework for IVUS–OCT co-registration demonstrated both speed and accuracy, with performance comparable to that of expert analysts. These features enable its application in research using large-scale data incorporating multimodality imaging.