Thamil Kumaran S. M.

Thamil Kumaran S. M.

Auto-generated profile, based on publicly available information

Thamil Kumaran S. M.

Centre for Cardiovascular Medicine and Devices, William Harvey Research Institute (A.R., T.K.S.M., A. Mathur, A.B., C.V.B.), Queen Mary University of London, United Kingdom

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2022 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
SKS. M. Thamil Kumaran
S. M. Thamil Kumaran
BPB. Premachandran
B. Premachandran
In this article, a numerical investigation carried out on saturated flow film boiling overtwo cylinders placed in an inline arrangement has been discussed. Water at near critical condition, p/pc = 0.99, is considered for all simulations, where pc is the critical pressure of water. In this study buoyancy assisted flow is considered. The effects of different liquid Reynolds number ReD and wall superheat on heat transfer rates are studied for different spacings between the two cylinders. Interface structures and their modes of evolution greatly vary for different cases investigated. For some cases, especially for those with lower spacing between the cylinders, a steady vapour column connecting both cylinders in the gap region between them is formed. At higher flow rates, the vapour column in the gap region is unstable. At some cases where re-circulation zones are formed, the vapour column breaks-off. The heat transfer rate from the rear cylinder is significantly affected by the modes of phase-interface evolution and the types of flow structures formed in the gap region between cylinders. It is found that the flow structures and the phase-interface evolution are strongly dependent on the distance between the two cylinders for a givenReynolds number and a non-dimensional wall superheat.

1 August 2023 in Physics of Fluids
Verified
Journal Article
Open access
PDF file
TMThamil Kumaran S. M.
Thamil Kumaran S. M.
BPB. Premachandran
B. Premachandran
Mixed convection film boiling in a system of two cylinders positioned in an in-line configuration is numerically studied. The relative importance of inertia over buoyancy is given by Froude number. The direction of the incoming saturated liquid is perpendicular to the direction of gravity. Simulations are performed for the Reynolds number values of 50, 100, and 150; non-dimensional wall superheat values of 0.3, 0.6, and 0.9; and non-dimensional spacing between cylinders values of 2.0, 4.0, and 6.0. Three modes of vortex shedding from the cylinders are identified. An increase in the Reynolds number increases the heat transfer for the upstream cylinder and decreases heat transfer for the downstream cylinder. Increasing the non-dimensional wall superheat leads to decrease in the heat transfer rate from both the cylinders. Changing the non-dimensional spacing between the cylinders does not significantly alter the heat transfer from the upstream cylinder. However, heat transfer rate from the downstream cylinder increases significantly with increase in the non-dimensional spacing between the cylinders. The dynamic interface is affected by the shear layer instability and the vortex shedding pattern, which in turn affects the vapor film thickness around the cylinders and the rates of heat transfer from the cylinders.

15 October 2025 in Journal of Cardiovascular Computed Tomography
Verified
Journal Article
Closed access
ASAkash Sivananthan
Akash Sivananthan
TSThamil Kumaran S.M.
Thamil Kumaran S.M.
ITIbrahim Halil Tanboga
Ibrahim Halil Tanboga
AMAmear Mohammed
Amear Mohammed
ARAnantharaman Ramasamy
Anantharaman Ramasamy
Christos BourantasChristos Bourantas
Christos Bourantas

16 January 2026 in European Heart Journal - Digital Health
Verified
Journal Article
Open access
XHXingwei He
Xingwei He
KBKit Mills Bransby
Kit Mills Bransby
AUAhmet Emir Ulutas
Ahmet Emir Ulutas
TKThamil Kumaran
Thamil Kumaran
NYNathan Angelo Lecaros Yap
Nathan Angelo Lecaros Yap
Christos BourantasChristos Bourantas
Christos Bourantas
Aims: To develop a deep-learning (DL) framework that enables fully automated longitudinal and circumferential co-registration of intravascular ultrasound (IVUS) and optical coherence tomography (OCT) images. Methods and results: Data from 230 patients (714 vessels) with acute myocardial infarction that underwent near-infrared spectroscopy IVUS and OCT imaging in their non-infarct related vessels were analysed. Experts annotated the lumen borders (61 655 IVUS and 62 334 OCT frames), the side branches and the calcific tissue (10 000 IVUS and 10 000 OCT frames each). This information was used to train DL models that extracted these features that were then used by a dynamic time warping algorithm to co-registered longitudinally the IVUS and OCT images. The circumferential registration of IVUS and OCT was performed through a rotation cost matrix and dynamic programming. On a test set of 22 patients (77 vessels), the DL method showed high concordance with the expert analysts for the longitudinal and circumferential co-registration of the two datasets (concordance correlation coefficient >0.99 and >0.90, respectively). The Williams Index was 0.96 for longitudinal and 0.97 for circumferential alignment, indicating a comparable performance of the proposed framework to the analysts. The time needed for the DL pipeline to process imaging data from a vessel was <90 s. Conclusion: A fully automated, DL-based framework for IVUS–OCT co-registration demonstrated both speed and accuracy, with performance comparable to that of expert analysts. These features enable its application in research using large-scale data incorporating multimodality imaging.

1 July 2026 in Arteriosclerosis, Thrombosis, and Vascular Biology
Verified
Journal Article
Closed access
ARAnantharaman Ramasamy
Anantharaman Ramasamy
ASAkash Sivananthan
Akash Sivananthan
ITIbrahim Halil Tanboga
Ibrahim Halil Tanboga
TSThamil Kumaran S.M.
Thamil Kumaran S.M.
AMAmear Mohammed
Amear Mohammed
Christos BourantasChristos Bourantas
Christos Bourantas
BACKGROUND: The incorporation of side branches in vessel geometry influences wall shear stress (WSS) distribution. However, complete vessel reconstruction is time-consuming, and there is no evidence that its WSS estimations better predict atherosclerotic disease progression compared with the output of the conventional single-vessel reconstruction (SVR). METHODS: Patients who had baseline and 1-year follow-up intravascular ultrasound imaging (n=40 vessels), and patients with neoatherosclerotic lesions (n=13 vessels) on optical coherence tomography were included. All the studied vessels had at least one side branch with a diameter >1 mm; 3-dimensional complete vessel reconstruction and SVR were performed, and the time-averaged WSS and multidirectional WSS were computed. The performance of both methods in predicting disease progression in intravascular ultrasound and optical coherence tomography models was assessed. RESULTS: The incorporation of side branches in 3-dimensional geometry resulted in lower minimum predominant time-averaged WSS in the intravascular ultrasound (1.09 versus 1.58 Pa, P <0.001) and optical coherence tomography–based reconstructions (0.68 versus 1.33 Pa, P <0.001) and influenced the multidirectional WSS distribution. In native segments, complete vessel reconstruction–derived WSS metrics demonstrated superior predictive performance for disease progression—defined as lumen area reduction and plaque burden increase—compared with SVR, as evidenced by improved out-of-sample accuracy (leave-one-out information criterion: 429 versus 551), discrimination (C statistic: 0.725 versus 0.651), calibration (Brier score: 0.172 versus 0.226), and explained variance (27.8% versus 20.7%). Consistent findings were observed in stented segments, where complete vessel reconstruction–derived WSS metrics more accurately predicted neointimal proliferation than SVR-derived metrics. CONCLUSIONS: Incorporating side branches into vessel reconstruction influences WSS distribution and enables more accurate prediction of atherosclerotic disease progression in native and stented segments than SVR.