Yiqun Wu

Yiqun Wu

Auto-generated profile, based on publicly available information

Yiqun Wu

Company of State Grid Ganzhou Power Supply, Ganzhou, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XHXinbo Huang
Xinbo Huang
YWYiqun Wu
Yiqun Wu
YZYe Zhang
Ye Zhang
BLBotao Li
Botao Li
Overhead transmission lines suffer from extended exposure to harsh weather conditions. Metal dampers, a crucial protective fitting in the line, can effectively suppress the conductor’s vibration energy and prevent aeolian vibration and ice shedding. To ensure the safety of operation of the damper, we are proposing a detection method for structural defect damper based on spatial relationship. First, the UAV aerial damper images are processed with relative total variation (RTV) transform to obtain an enhanced image with smooth texture and prominent foreground main structure. Second, the enhanced image is corrected by rotation so that the conductor remains horizontal. Next, based on the endpoint coordinates of the conductor, a foreground pre-selection box for improved GrabCut segmentation is automatically generated to extract the object dampers. Finally, the spatial relationship between the damper components in the segmentation results is regarded as the motive force of the damper structural defect diagnosis model to detect damage, inversion, slight and serious deformation defects in sequence. We analyzed the performance of the proposed method through actual field tests, and the results demonstrated that the identification accuracy of the method is 95.76% when applied to a small sample set, which is higher than other existing methods based on traditional image techniques and deep learning defect detection, and can effectively identify different structural defects of dampers and provide reliable data for transmission line condition monitoring.

1 November 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XHXinbo Huang
Xinbo Huang
YWYiqun Wu
Yiqun Wu
YZYe Zhang
Ye Zhang
HZHuiying Zhang
Huiying Zhang
The conductor loosened fault of transmission line caused by its own mechanical load, breeze vibration and galloping will gradually worsen by the passage of time, and even lead to a series of irreversible accidents such as conductor breakage and tower fall. In order to detect loosened conductors as soon as possible and minimize the possible damages, a detection method for loosened conductor based on vision sensor is proposed. Firstly, conductor images are captured by image acquisition system, utilizing the inspection robot, and then the energy gradient algorithm with guided filtering (GEG) is performed to highlight the foreground and strengthen the hierarchy, so that the conductor area can be obtained by Otsu threshold segmentation. Secondly, the surface contour of the conductor is extracted, filtered and numbered. Finally, according to the arrangement characteristics of the outermost Al-strands of the conductor, we established a conductor loosened model which includes the analysis of four feature quantities of contour length D, direction angle θ, curvature W and spacing T and the thinning process based on Step-Vertical limit (SVL) to judge the conductor fault and locate the loosened strands. We analyze the performance of the technology by tests, the results demonstrate that the proposed method can quickly detect conductor loosened fault and achieve good performance.