2 July 2026 in Engineering Research Express
Vacuum interrupters with composite transverse magnetic-field and longitudinal magnetic-field contacts have attracted increasing attention because of their potential advantages in arc control and current-carrying performance. However, the temperature-rise behavior, heat-source distribution, and influence mechanism of key structural parameters in composite TMF-AMF contact vacuum interrupters have not been sufficiently clarified. To address this issue, a three-dimensional bidirectional electromagnetic–thermal coupled simulation model is established in this study. The eddy-current field is solved in Maxwell under rated current conditions, and the calculated Ohmic loss is then transferred to the steady-state thermal solver as the volumetric Joule heat source. Based on this model, the effects of contact force, TMF contact diameter, conducting rod diameter, contact material, envelope material, and external convective heat-transfer coefficient on the temperature field are investigated. The results show that the maximum temperature occurs near the conductive bridge at the contact interface, where current constriction causes concentrated Ohmic loss. Increasing the contact force, TMF contact diameter, and conducting rod diameter can effectively reduce the maximum temperature, but the cooling effect gradually weakens beyond certain parameter ranges. Material comparison indicates that the electrical and thermal conductivities of contact materials jointly determine the temperature-rise level. In addition, a ceramic envelope provides better heat-transfer performance than a glass envelope, and increasing the external convective heat-transfer coefficient reduces the peak temperature with diminishing returns. This study clarifies the electromagnetic–thermal coupling mechanism of composite TMF-AMF contact vacuum interrupters and provides simulation support for temperature-rise control and structural design.
1 January 2026 in IEEE Transactions on Instrumentation and Measurement
2 July 2026 in Engineering Research Express
Investigating the arc control capability of different environmental gases in trigger-gap switches holds significant value for researching SF 6 alternative gas applications. This study focuses on 30%/70% SF 6 /N 2 , 10%/90%C 4 F 7 N/CO 2 , and SF 6 insulating gases. By constructing a three-dimensional magnetohydrodynamic model and using Fluent software, we simulated the arc burning process of a 110 mm diameter six-petaled transverse magnetic spiral groove electrode in trigger-gap switches under 0.3 MPa pressure, analyzing arc control capability in different insulating gases. The results show that the Lorentz force is too strong in pure SF 6 gas, the arc is blown out of the electrode plate, and the average arc volume is small. In the 10%/90%C₄F₇N/CO₂ and 30%/70% SF₆/N₂ gas mixtures, the early-stage arcs exhibit short-column rotation around the electrode plate edge. These results indicate that the 10%/90%C₄F₇N/CO₂ mixture exhibits certain arc control characteristics under the investigated electrode structure and operating condition. Notably, the 10%/90%C 4 F 7 N/CO 2 gas arc diffuses earlier than the 30%/70% SF 6 /N 2 gas arc. This research provides valuable references for developing SF 6 alternative gas applications.