Mehran Azimbagirad

Mehran Azimbagirad

Auto-generated profile, based on publicly available information

Mehran Azimbagirad

Satsuma Lab, Hawke's Institute, University College London, London, United Kingdom

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2022 in Neuroscience Informatics
Verified
Journal Article
Open access
SRSaeid Raziani
Saeid Raziani
MAMehran Azimbagirad
Mehran Azimbagirad

12 July 2021 in Journal of Digital Imaging
Verified
Journal Article
Closed access
PDF file
VFVanessa De Araujo Faria
Vanessa De Araujo Faria
MAMehran Azimbagirad
Mehran Azimbagirad
GAGustavo Viani Arruda
Gustavo Viani Arruda
JPJuliana Fernandes Pavoni
Juliana Fernandes Pavoni
JFJoaquim Cezar Felipe
Joaquim Cezar Felipe
LJLuiz Otavio Murta Junior
Luiz Otavio Murta Junior

1 July 2019 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
YHYaser Hadadian
Yaser Hadadian
MAMehran Azimbagirad
Mehran Azimbagirad
ENElcio A. Navas
Elcio A. Navas
Theo PavanTheo Pavan
Theo Pavan
In recent decades, magnetic hyperthermia using magnetic nanoparticles, a promising but quite challenging method, has proven to be an effective cancer therapy procedure. In hyperthermia, heat, which is generated by magnetic nanoparticles exposed to a radiofrequency magnetic field, is employed to battle cancerous cells. Ideally, devices for magnetic hyperthermia should provide a variety of field amplitudes and frequencies for generating an appropriate and powerful alternating magnetic field. Here, we report the design and evaluation of a versatile system which provides different experimental setup possibilities for magnetic hyperthermia. The proposed system is a derivative of the Mazzilli inverter, which directly follows the resonant frequency of the LC tank circuit independent of its component. The feasibility of the system for hyperthermia studies was examined using iron oxide nanoparticles prepared by the coprecipitation method. Different experimental conditions including nanoparticles in solution and dispersed in gelatin phantoms were evaluated. Four different coils including two solenoids, a pancake, and a Helmholtz-like format were successfully tested. Using these coils, 18 different operation frequencies in the frequency band of 63–530 kHz with field strengths up to 27.2 kA/m were achieved.

1 September 2021 in Neuroscience Informatics
Verified
Journal Article
Open access
MAMehran Azimbagirad
Mehran Azimbagirad
LMLuiz Murta
Luiz Murta

4 February 2026 in Communications Medicine
Verified
Journal Article
Open access
PDF file
NMNiccolò McConnell
Niccolò McConnell
PVPardeep Vasudev
Pardeep Vasudev
DYDaisuke Yamada
Daisuke Yamada
DCDaryl Cheng
Daryl Cheng
MAMehran Azimbagirad
Mehran Azimbagirad
JJJoseph Jacob
Joseph Jacob
Background: Low-dose computed tomography (LDCT) employed in lung cancer screening (LCS) programmes is increasing in uptake worldwide. LCS programmes herald a generational opportunity to simultaneously detect cancer and non-cancer-related early-stage lung disease, yet these efforts are hampered by a shortage of radiologists to interpret scans at scale. Here, we present TANGERINE, a computationally frugal, open-source vision foundation model for volumetric LDCT analysis. Methods: Designed for broad accessibility and rapid adaptation, TANGERINE can be fine-tuned off the shelf for a wide range of disease-specific tasks with limited computational resources and training data. The model is pretrained using self-supervised learning on more than 98,000 thoracic LDCT scans, including the United Kingdom’s largest LCS initiative to date and 27 public datasets. By extending a masked autoencoder framework to three-dimensional imaging, TANGERINE provides a scalable solution for LDCT analysis, combining architectural simplicity, public availability, and modest computational requirements. Results: TANGERINE demonstrates superior computational and data efficiency in a retrospective multi-dataset analysis: it converges rapidly during fine-tuning, requiring significantly fewer graphics processing unit hours than models trained from scratch, and achieves comparable or superior performance using only a fraction of the fine-tuning data. The model achieves strong performance across 14 disease classification tasks, including lung cancer and multiple respiratory diseases, and generalises robustly across diverse clinical centres. Conclusions: TANGERINE’s accessible, open-source, lightweight design lays the foundation for rapid integration into next-generation medical imaging tools, enabling lung cancer screening programmes to pivot from a singular focus on lung cancer detection toward comprehensive respiratory disease management in high-risk populations.

29 January 2021 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
MAMehran Azimbagirad
Mehran Azimbagirad
FGFelipe Wilker Grillo
Felipe Wilker Grillo
YHYaser Hadadian
Yaser Hadadian
ACAntonio Adilton Oliveira Carneiro
Antonio Adilton Oliveira Carneiro
LMLuiz Murta
Luiz Murta
<!-- *** Custom HTML *** --> Purpose: Brain image volumetric measurements (BVM) methods have been used to quantify brain tissue volumes using magnetic resonance imaging (MRI) when investigating abnormalities. Although BVM methods are widely used, they need to be evaluated to quantify their reliability. Currently, the gold-standard reference to evaluate a BVM is usually manual labeling measurement. Manual volume labeling is a time-consuming and expensive task, but the confidence level ascribed to this method is not absolute. We describe and evaluate a biomimetic brain phantom as an alternative for the manual validation of BVM. Methods: We printed a three-dimensional (3D) brain mold using an MRI of a three-year-old boy diagnosed with Sturge-Weber syndrome. Then we prepared three different mixtures of styrene-ethylene/butylene-styrene gel and paraffin to mimic white matter (WM), gray matter (GM), and cerebrospinal fluid (CSF). The mold was filled by these three mixtures with known volumes. We scanned the brain phantom using two MRI scanners, 1.5 and 3.0 Tesla. Our suggestion is a new challenging model to evaluate the BVM which includes the measured volumes of the phantom compartments and its MRI. We investigated the performance of an automatic BVM, i.e., the expectation–maximization (EM) method, to estimate its accuracy in BVM. Results: The automatic BVM results using the EM method showed a relative error (regarding the phantom volume) of 0.08, 0.03, and 0.13 (±0.03 uncertainty) percentages of the GM, CSF, and WM volume, respectively, which was in good agreement with the results reported using manual segmentation. Conclusions: The phantom can be a potential quantifier for a wide range of segmentation methods.