Chenxi Sun

Chenxi Sun

Auto-generated profile, based on publicly available information

Chenxi Sun

Harvard Medical School, Boston

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2022 in IEEE Transactions on Artificial Intelligence
Verified
Journal Article
Closed access
CSChenxi Sun
Chenxi Sun
MSMoxian Song
Moxian Song
DCDerun Cai
Derun Cai
BZBaofeng Zhang
Baofeng Zhang
SHShenda Hong
Shenda Hong
HLHongyan Li
Hongyan Li
Recurrent Neural Network (RNN) has demonstrated its outstanding ability in sequence tasks and has achieved state-of-the-art in many applications, such as industrial and medical. Echo State Network (ESN) is a simple type of RNN and has emerged in the last decade as an alternative to gradient descent training-based RNN. ESN is practical, conceptually simple, and easy to implement with a strong theoretical ground. It can avoid non-converging and computationally expensive issues in gradient descent RNN methods. Since ESN was put forward in 2002, abundant existing works have promoted the progress of ESN, and the recently introduced deep ESN opened the way to uniting the merits of deep learning and reservoir computing. Besides, the combinations of ESNs with other machine learning models have also overperformed baselines in some applications. However, the apparent simplicity of ESNs can sometimes be deceptive. Successfully applying ESNs needs some experience. Thus, we reviewed over 300 related papers and provided a systematic overview for the first time. In this paper, we categorize the related methods into classical ESN, DeepESN, and combination. Then, we analyze them from the perspective of network designs and specific applications. Finally, we discuss the challenges and opportunities by proposing open problems and future work.

26 June 2025 in NEJM AI
Verified
Journal Article
Closed access
JLJun Li
Jun Li
AAAaron D. Aguirre
Aaron D. Aguirre
VJValdery Moura Junior
Valdery Moura Junior
JJJiarui Jin
Jiarui Jin
CLChe Liu
Che Liu
SHShenda Hong
Shenda Hong
Artificial intelligence (AI) has demonstrated significant potential in electrocardiogram (ECG) analysis and cardiovascular disease assessment. Recently, foundation models have played a remarkable role in advancing medical AI, bringing benefits such as efficient disease diagnosis and cross-domain knowledge transfer. The development of an ECG foundation model holds the promise of elevating AI-ECG research to new heights. However, building such a model poses several challenges, including insufficient database sample sizes and inadequate generalization across multiple domains. In addition, there is a notable performance gap between single-lead and multilead ECG analysis. We propose a general-purpose ECG foundation model (ECGFounder), which leverages real-world ECG annotations from cardiologists to broaden the diagnostic capabilities of ECG analysis. ECGFounder was built on 10,771,552 ECGs from 1,818,247 unique subjects with 150 label categories from the Harvard-Emory ECG Database, enabling comprehensive cardiovascular disease diagnosis. The model is designed to be both an effective out-of-the-box solution and easily fine-tunable for downstream tasks, maximizing usability. Importantly, we extended its application to reduced-lead ECGs, particularly single-lead ECGs. ECGFounder is therefore applicable to various downstream tasks in mobile and remote monitoring scenarios. Experimental results demonstrate that ECGFounder achieves expert-level performance on internal validation sets, with area under the receiver operating characteristic curve (AUROC) exceeding 0.95 for 80 diagnoses. It also shows strong classification performance and generalization across various diagnoses on external validation sets. When fine-tuned, ECGFounder outperforms baseline models in demographic analysis, clinical event detection, and cross-modality cardiac rhythm diagnosis, surpassing baseline methods by 3 to 5 points in the AUROC. The ECG foundation model offers an effective solution, allowing it to generalize across a wide range of tasks. By enhancing existing cardiovascular diagnostics and facilitating integration with cloud-based systems, which analyze ECG data uploaded from wearable devices, it significantly contributes to the advancement of the cardiovascular AI community and enables management of cardiac conditions. (Funded by the National Science Foundation and others.).

20 October 2023 in Pattern Recognition
Verified
Journal Article
Closed access
CSChenxi Sun
Chenxi Sun
HLHongyan Li
Hongyan Li
MSMoxian Song
Moxian Song
DCDerun Cai
Derun Cai
BZBaofeng Zhang
Baofeng Zhang
SHShenda Hong
Shenda Hong

14 March 2023 in IEEE Transactions on Neural Networks and Learning Systems
Verified
Journal Article
Closed access
CSChenxi Sun
Chenxi Sun
HLHongyan Li
Hongyan Li
MSMoxian Song
Moxian Song
SHShenda Hong
Shenda Hong
Early classification tasks aim to classify time series before observing full data. It is critical in time-sensitive applications such as early sepsis diagnosis in the intensive care unit (ICU). Early diagnosis can provide more opportunities for doctors to rescue lives. However, there are two conflicting goals in the early classification task—accuracy and earliness. Most existing methods try to find a balance between them by weighing one goal against the other. But we argue that a powerful early classifier should always make highly accurate predictions at any moment. The main obstacle is that the key features suitable for classification are not obvious in the early stage, resulting in the excessive overlap of time series distributions in different time stages. The indistinguishable distributions make it difficult for classifiers to recognize. To solve this problem, this article proposes a novel ranking-based cross-entropy () loss to jointly learn the feature of classes and the order of earliness from time series data. In this way, can help classifier to generate probability distributions of time series in different stages with more distinguishable boundary. Thus, the classification accuracy at each time step is finally improved. Besides, for the applicability of the method, we also accelerate the training process by focusing the learning process on high-ranking samples. Experiments on three real-world datasets show that our method can perform classification more accurately than all baselines at all moments.

4 June 2025 in Epilepsia
Verified
Journal Article
Open access
CSChenxi Sun
Chenxi Sun
JJJin Jing
Jin Jing
NTNiels Turley
Niels Turley
CACallison Alcott
Callison Alcott
WKWan‐Yee Kang
Wan‐Yee Kang
MWMichael Brandon Westover
Michael Brandon Westover
Objective: This article presents the Harvard Electroencephalography Database (HEEDB), a large‐scale, deidentified, and standardized electroencephalographic (EEG) resource supporting artificial intelligence‐driven and reproducible research in epilepsy and broader clinical neuroscience.Methods: HEEDB aggregates more than 280 000 EEG recordings from more than 108 000 patients across four Harvard‐affiliated hospitals. Data are harmonized using the Brain Imaging Data Structure and hosted on the Brain Data Science Platform. EEG data are linked with clinical notes, International Classification of Diseases, 10th Revision codes, medications, and EEG reports. Deidentification follows Health Insurance Portability and Accountability Act Safe Harbor standards.Results: The database includes routine, epilepsy monitoring unit, and intensive care unit EEGs across all age groups, with 73% linked to deidentified clinical reports and 96% of those matched to recordings. Findings are extracted using expert curation, regular expressions, and medical natural language processing models. Auxiliary data include diagnoses, medications, and hospital course, supporting multimodal analysis.Significance: HEEDB fills a critical gap in EEG data availability for epilepsy research. By enabling large‐scale, privacy‐compliant, and clinically relevant analysis, it accelerates the development of diagnostic tools, improves training datasets for machine learning, and promotes data‐sharing in alignment with FAIR (Findable, Accessible, Interoperable, Reusable) and National Institutes of Health data policies.

26 June 2025 in NEJM AI
Verified
Journal Article
Closed access
JLJun Li
Jun Li
Daniel M GoldenholzDaniel M Goldenholz
Daniel M Goldenholz
MAMoritz Alkofer
Moritz Alkofer
CSChenxi Sun
Chenxi Sun
FNFabio A. Nascimento
Fabio A. Nascimento
JJJin Jing
Jin Jing
Epileptiform discharges, or spikes, within electroencephalogram (EEG) recordings are essential for diagnosing epilepsy and localizing seizure origins. Artificial intelligence (AI) offers a promising approach to automating detection, but current models are often hindered by artifact-related false positives and often target either event- or EEG-level classification, thus limiting clinical utility. We developed SpikeNet2, a deep-learning model based on a residual network architecture, and enhanced it with hard-negative mining to reduce false positives. Our study analyzed 17,812 EEG recordings from 13,523 patients across multiple institutions, including Massachusetts General Brigham (MGB) hospitals. Data from the Human Epilepsy Project (HEP) and SCORE-AI (SAI) were also included. A total of 32,433 event-level samples, labeled by experts, were used for training and evaluation. Performance was assessed using the area under the receiver operating characteristic curve (AUROC), the area under the precision–recall curve (AUPRC), calibration error, and a modified area under the curve (mAUC) metric. The model’s generalizability was evaluated using external datasets. SpikeNet2 demonstrated strong performance in event-level spike detection, achieving an AUROC of 0.973 and an AUPRC of 0.995, with 44% of experts surpassing the model on the MGB dataset. In external validation, the model achieved an AUROC of 0.942 and an AUPRC of 0.948 on the HEP dataset. For EEG-level classification, SpikeNet2 recorded an AUROC of 0.958 and an AUPRC of 0.959 on the MGB dataset, an AUROC of 0.888 and an AUPRC of 0.823 on the HEP dataset, and an AUROC of 0.995 and an AUPRC of 0.991 on the SAI dataset, with 32% of experts outperforming the model. The false-positive rate was reduced to an average of nine spikes per hour. SpikeNet2 offers expert-level accuracy in both event-level spike detection and EEG-level classification, while significantly reducing false positives. Its dual functionality and robust performance across diverse datasets make it a promising tool for clinical and telemedicine applications, particularly in resource-limited settings. (Funded by the National Institutes of Health and others.)