Moritz Alkofer

Moritz Alkofer

Auto-generated profile, based on publicly available information

Moritz Alkofer

Harvard Medical School, Boston

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2025 in NEJM AI
Verified
Journal Article
Closed access
JLJun Li
Jun Li
Daniel M GoldenholzDaniel M Goldenholz
Daniel M Goldenholz
MAMoritz Alkofer
Moritz Alkofer
CSChenxi Sun
Chenxi Sun
FNFabio A. Nascimento
Fabio A. Nascimento
JJJin Jing
Jin Jing
Epileptiform discharges, or spikes, within electroencephalogram (EEG) recordings are essential for diagnosing epilepsy and localizing seizure origins. Artificial intelligence (AI) offers a promising approach to automating detection, but current models are often hindered by artifact-related false positives and often target either event- or EEG-level classification, thus limiting clinical utility. We developed SpikeNet2, a deep-learning model based on a residual network architecture, and enhanced it with hard-negative mining to reduce false positives. Our study analyzed 17,812 EEG recordings from 13,523 patients across multiple institutions, including Massachusetts General Brigham (MGB) hospitals. Data from the Human Epilepsy Project (HEP) and SCORE-AI (SAI) were also included. A total of 32,433 event-level samples, labeled by experts, were used for training and evaluation. Performance was assessed using the area under the receiver operating characteristic curve (AUROC), the area under the precision–recall curve (AUPRC), calibration error, and a modified area under the curve (mAUC) metric. The model’s generalizability was evaluated using external datasets. SpikeNet2 demonstrated strong performance in event-level spike detection, achieving an AUROC of 0.973 and an AUPRC of 0.995, with 44% of experts surpassing the model on the MGB dataset. In external validation, the model achieved an AUROC of 0.942 and an AUPRC of 0.948 on the HEP dataset. For EEG-level classification, SpikeNet2 recorded an AUROC of 0.958 and an AUPRC of 0.959 on the MGB dataset, an AUROC of 0.888 and an AUPRC of 0.823 on the HEP dataset, and an AUROC of 0.995 and an AUPRC of 0.991 on the SAI dataset, with 32% of experts outperforming the model. The false-positive rate was reduced to an average of nine spikes per hour. SpikeNet2 offers expert-level accuracy in both event-level spike detection and EEG-level classification, while significantly reducing false positives. Its dual functionality and robust performance across diverse datasets make it a promising tool for clinical and telemedicine applications, particularly in resource-limited settings. (Funded by the National Institutes of Health and others.)

3 May 2025 in Epilepsia
Verified
Journal Article
Open access
MAMoritz Alkofer
Moritz Alkofer
CYChaoqi Yang
Chaoqi Yang
WGWolfgang Ganglberger
Wolfgang Ganglberger
JBJules Beal
Jules Beal
MHManu Hegde
Manu Hegde
MWMichael Brandon Westover
Michael Brandon Westover
Interictal epileptiform discharges (IEDs) are crucial for epilepsy diagnosis and management. New electroencephalographic (EEG) devices with fewer electrodes are more accessible, but their ability to detect IEDs is uncertain. The aim of this study is to determine whether IEDs can be reliably detected in reduced‐channel EEG data, enabling broader epilepsy diagnosis. Using EEG samples from 3378 patients and an external validation set of 51 patients, we trained Cyclops, a deep neural network designed to function across various channel configurations. Performance was evaluated using area under the receiver operating characteristic curve (AUROC) and other clinically relevant metrics, including IED source location sensitivity. Cyclops demonstrated strong performance even with minimal channels. AUROC for one channel was .876 (95% confidence interval [CI] = .854–.897); best configuration based on a clinically available product was .950 (95% CI = .936–.962); for the detection of focal IEDs with two local channels, AUROC values ranged from .701 (95% CI = .656–.745) to .930 (95% CI = .902–.955), with a median AUROC of .809. On the external validation set, performance ranged from .692 (95% CI = .593–.782) to .949 (95% CI = .922–.972), with a median AUROC of .846. Thus, Cyclops demonstrates that effective IED detection is possible with reduced EEG setups, enhancing accessibility and expanding epilepsy diagnosis to broader patient populations.