Aims: Device-related infection (DRI) is a severe complication to cardiac implantable electronic devices (CIED) therapy. Device-related infection incidence and its risk factors differ between previous studies. We aimed to define the long-term incidence and incidence rates of DRI for different types of CIEDs in the complete Danish device-cohort and identify patient-, operation- and device-related risk factors for DRI.Methods and results: From the Danish Pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Register, we included consecutive Danish patients undergoing CIED implantation or reoperation from January 1982 to April 2018, resulting in 97 750 patients, 128 045 operations and follow-up of in total 566 275 device years (DY). We identified 1827 DRI causing device removals. Device-related infection incidence during device lifetime was 1.19% (1.12–1.26) for PM, 1.91% (1.71–2.13) for ICD, 2.18% (1.78–2.64) for cardiac resynchronization therapy (CRT)-pacemakers (CRT-P), and 3.35% (2.92–3.83) for CRT-defibrillators (CRT-D). Incidence rates in de novo implantations were 2.04/1000 DY for PM, 3.84 for ICD, 4.38 for CRT-P, and 6.76 for CRT-D. Using multiple-record and multiple-event per subject proportional hazard analysis, we identified implantation of complex devices (ICD and CRT), reoperations, prior DRI, male sex, and younger age as significantly associated with higher DRI risk.Conclusion: Overall risk of infection was low in PM implantations but considerably higher in CRT systems and after reinterventions. These data support the importance of evaluating all patients considered for CIED therapy thoroughly, in order to identify potential modifiable risk factors and reduce the risk of early reoperations.
Cardiac implantable electronic device (CIED) infection is a severe complication to modern management of cardiac arrhythmias. The CIED type and the type of surgery are recognized as risk factors for CIED infections, but knowledge of patient-related risk factors is scarce. This study aimed to identify lifelong patient-related risk factors for CIED infections. Consecutive Danish patients undergoing a CIED implantation or reoperation between January 1996 and April 2018 were included. The cohort consisted of 84 429 patients undergoing 108 494 CIED surgeries with a combined follow-up of 458 257 CIED-years. A total of 1556 CIED explantations were classified as either pocket (n = 1022) or systemic CIED infection (n = 534). Data were cross-linked with records from the Danish National Patient Registry and the Danish National Prescription Registry. Using multiple-record and multiple-event per subject proportional hazard analysis, specific patient-related risk factors were identified but with several variations amongst the subtypes of CIED infection. CIED reoperations were associated with the highest risk of pocket CIED infection but also CIED type, young age, and prior valvular surgery [hazard ratio (HR): 1.62, 95% confidence interval (CI): 1.29–2.04]. Severe renal insufficiency/dialysis (HR: 2.40, 95% CI: 1.65–3.49), dermatitis (HR: 2.80, 95% CI: 1.92–4.05), and prior valvular surgery (HR: 2.09, 95% CI: 1.59–2.75) were associated with the highest risk of systemic CIED infections. Congestive heart failure, ischaemic heart disease, malignancy, chronic obstructive pulmonary disease, and temporary pacing were not significant at multivariate analysis. Specific comorbidities and surgical procedures were associated with a higher risk of CIED infections but with variations amongst pocket and systemic CIED infection. Pocket CIED infections were associated with CIED reoperations, young age and more complex type of CIED, whereas systemic CIED infections were associated with risk factors predisposing to bacteraemia.
Use of an absorbable antibacterial envelope during implantation prevents cardiac implantable electronic device infections in patients with a moderate-to-high infection risk. Previous studies demonstrated that an envelope is cost-effective in high-risk patients within German, Italian, and English healthcare systems, but these analyses were based on limited data and may not be generalizable to other healthcare settings. A previously published decision-tree-based cost-effectiveness model was used to compare the costs per quality-adjusted life year (QALY) associated with adjunctive use of an antibacterial envelope for infection prevention compared to standard-of-care intravenous antibiotics. The model was adapted using data from a Danish observational two-centre cohort study that investigated infection-risk patients undergoing cardiac resynchronization therapy (CRT) reoperations with and without an antibacterial envelope (n = 1943). We assumed a cost-effectiveness threshold of €34 125/QALY gained, based on the upper threshold used by the National Institute for Health and Care Excellence (£30 000). An antibacterial envelope was associated with an incremental cost-effectiveness ratio (ICER) of €12 022 per QALY in patients undergoing CRT reoperations, thus indicating that the envelope is cost-effective when compared with standard of care. A separate analysis stratified by device type showed ICERS of €6227 (CRT defibrillator) and €29 177 (CRT pacemaker) per QALY gained. Cost-effectiveness ratios were favourable for patients undergoing CRT reoperations in the Danish healthcare system, and thus are in line with previous studies. Results from this study can contribute to making the technology available to Danish patients and align preventive efforts in the pacemaker and ICD area. CIED, cardiac implantable electronic device; CRT, cardiac resynchronization therapy (-P, pacemaker; -D, defibrillator); ICER, incremental cost-effectiveness ratio; HR, hazard ratio; IQR, interquartile range; QALY, quality-adjusted life year.
Device-related infection (DRI) is a severe complication of treatment with cardiac implantable electronic devices. Identification of the causative pathogen is essential for optimal treatment, but conventional methods often are inadequate. The purpose of this study was to improve microbiological diagnosis in DRI using sonication and next-generation sequencing analysis. The primary objective was identification of causative pathogens. The secondary objective was estimation of the sensitivity of different microbiological methods in detecting the causative pathogen. Consecutive patients with clinical signs of DRI between October 2016 and January 2019 from 3 tertiary centers in Denmark were included in the study. Patients underwent a diagnostic approach, including blood cultures and perioperative collection of microbiological samples (pocket swab, pocket tissue biopsies, generator, and leads). Conventional culturing was performed, and device components were sonicated and examined with an amplicon-based metagenomic analysis using next-generation sequencing. The results were compared with a reference standard-identified causative pathogen. In 110 patients with clinical signs of pocket (n = 50) or systemic DRI (n = 60), we collected 109 pocket swabs, 220 pocket tissue biopsies, 106 generators, 235 leads, and a minimum 1 set of blood cultures from 102 patients. Combining all findings, we identified the causative pathogen in 95% of cases, irrespective of DRI type. The usability of each microbiological method differed between DRI types. In pocket DRI, next-generation sequencing analysis of generators achieved sensitivity of 90%. For systemic DRI, blood cultures reached sensitivity of 93%. Using a strategy including sonication and next-generation sequencing, we identified the causative pathogen in 95% of DRI. Sensitivity of microbiological methods differed according to the type of DRI.