Cardiac implantable electronic device (CIED) infection is a severe complication to modern management of cardiac arrhythmias. The CIED type and the type of surgery are recognized as risk factors for CIED infections, but knowledge of patient-related risk factors is scarce. This study aimed to identify lifelong patient-related risk factors for CIED infections. Consecutive Danish patients undergoing a CIED implantation or reoperation between January 1996 and April 2018 were included. The cohort consisted of 84 429 patients undergoing 108 494 CIED surgeries with a combined follow-up of 458 257 CIED-years. A total of 1556 CIED explantations were classified as either pocket (n = 1022) or systemic CIED infection (n = 534). Data were cross-linked with records from the Danish National Patient Registry and the Danish National Prescription Registry. Using multiple-record and multiple-event per subject proportional hazard analysis, specific patient-related risk factors were identified but with several variations amongst the subtypes of CIED infection. CIED reoperations were associated with the highest risk of pocket CIED infection but also CIED type, young age, and prior valvular surgery [hazard ratio (HR): 1.62, 95% confidence interval (CI): 1.29–2.04]. Severe renal insufficiency/dialysis (HR: 2.40, 95% CI: 1.65–3.49), dermatitis (HR: 2.80, 95% CI: 1.92–4.05), and prior valvular surgery (HR: 2.09, 95% CI: 1.59–2.75) were associated with the highest risk of systemic CIED infections. Congestive heart failure, ischaemic heart disease, malignancy, chronic obstructive pulmonary disease, and temporary pacing were not significant at multivariate analysis. Specific comorbidities and surgical procedures were associated with a higher risk of CIED infections but with variations amongst pocket and systemic CIED infection. Pocket CIED infections were associated with CIED reoperations, young age and more complex type of CIED, whereas systemic CIED infections were associated with risk factors predisposing to bacteraemia.
Nearly one in ten patients experience complications in relation to cardiac implantable electronic device (CIED) implantations. CIED complications have serious implications for the patients and for the healthcare system. In light of the rising rates of new implants and consistent rate of complications, primary prevention remains a major concern. To guide future efforts, we sought to review the evidence base underlying common preventive actions made during a primary CIED implantation.
Use of an absorbable antibacterial envelope during implantation prevents cardiac implantable electronic device infections in patients with a moderate-to-high infection risk. Previous studies demonstrated that an envelope is cost-effective in high-risk patients within German, Italian, and English healthcare systems, but these analyses were based on limited data and may not be generalizable to other healthcare settings. A previously published decision-tree-based cost-effectiveness model was used to compare the costs per quality-adjusted life year (QALY) associated with adjunctive use of an antibacterial envelope for infection prevention compared to standard-of-care intravenous antibiotics. The model was adapted using data from a Danish observational two-centre cohort study that investigated infection-risk patients undergoing cardiac resynchronization therapy (CRT) reoperations with and without an antibacterial envelope (n = 1943). We assumed a cost-effectiveness threshold of €34 125/QALY gained, based on the upper threshold used by the National Institute for Health and Care Excellence (£30 000). An antibacterial envelope was associated with an incremental cost-effectiveness ratio (ICER) of €12 022 per QALY in patients undergoing CRT reoperations, thus indicating that the envelope is cost-effective when compared with standard of care. A separate analysis stratified by device type showed ICERS of €6227 (CRT defibrillator) and €29 177 (CRT pacemaker) per QALY gained. Cost-effectiveness ratios were favourable for patients undergoing CRT reoperations in the Danish healthcare system, and thus are in line with previous studies. Results from this study can contribute to making the technology available to Danish patients and align preventive efforts in the pacemaker and ICD area. CIED, cardiac implantable electronic device; CRT, cardiac resynchronization therapy (-P, pacemaker; -D, defibrillator); ICER, incremental cost-effectiveness ratio; HR, hazard ratio; IQR, interquartile range; QALY, quality-adjusted life year.
Aims : Cardiac resynchronization therapy (CRT) reoperations are associated with a particularly high risk of device-related infection (DRI). An antibacterial envelope reduces the occurrence of DRIs in a broad population of moderate-tohigh-risk patients. To investigate the efficacy of an antibacterial envelope in a very high-risk population of patients undergoing CRT reoperation. Methods and results: In this Danish two-centre, observational cohort study, we included consecutive patients who underwent a CRT pacemaker- or defibrillator reoperation procedure between January 2008 and November 2019. We obtained data from the Danish Pacemaker and ICD Register and through systematic medical chart review. Follow-up was restricted to 2 years. A total of 1943 patients were included in the study of which 736 (38%) received an envelope. Envelope patients had more independent risk factors for infection than non-envelope patients. Sixty-seven (3.4%) patients met the primary endpoint of DRI requiring device system extraction; 50 in the non-envelope group and 17 in the envelope group [4.1% vs. 2.3%, adjusted hazard ratio (HR) 0.52, 95% confidence interval (CI) 0.30–0.90; P = 0.021]. This difference persisted in propensity score analysis (HR 0.51, 95% CI 0.29–0.90; P = 0.019). Conclusion : Use of an antibacterial envelope was associated with a clinically and statistically significant reduction in DRIs in patients undergoing CRT reoperations. Our results were comparable to those recently reported from a large randomized controlled trial, which is suggestive of a proportional effect of the envelope even in very high-risk patients.
Cardiac electrophysiology is an evolving field that relies heavily on costly device- and catheter-based technologies. An increasing number of patients with heart rhythm disorders are becoming eligible for cardiac interventions, not least due to the rising prevalence of atrial fibrillation and increased longevity in the population. Meanwhile, the expansive costs of healthcare face finite societal resources, and a cost-conscious approach to new technologies is critical. Cost-effectiveness analyses support rational decision-making in healthcare by evaluating the ratio of healthcare costs to health benefits for competing therapies. They may, however, be subject to significant uncertainty and bias. This paper aims to introduce the basic concepts, framework, and limitations of cost-effectiveness analyses to clinicians including recent examples from clinical electrophysiology and device therapy.
Background We aimed to evaluate the association between atrial fibrillation (AF) burden, duration and number of episodes with healthcare utilisation and quality of life in patients with early paroxysmal AF without a history of AF. Methods In this observational cohort study, we included 417 patients with paroxysmal AF from the Reappraisal of Atrial Fibrillation: interaction between hyperCoagulability, Electrical remodelling and Vascular destabilisation in the progression of AF (RACE V) Study. Patients were monitored with an insertable cardiac monitor for 1 year. Outcomes collected were healthcare utilisation, and quality of life assessed using the Atrial Fibrillation Severity Scale and EuroQol EQ-5D-5L questionnaires. Results During 1 year of follow-up, 63 973 AF episodes were detected in 353 (85%) patients. The median AF burden was 0.7% (IQR 0.1–4.0%). AF ablation was performed more frequently in patients with intermediate-to-high AF burdens (>0.2%) (16.2% vs 5.9%, p=0.01) and longer AF episode duration (>1 hour) (15.8% vs 2.0%, p=0.01), whereas cardioversions were more frequent in patients with longer episode duration (>1 hour) (9.5% vs 0%, p=0.04) and intermediate (0.2–1.9%) (but not high) AF burdens (13.6% vs 4.2%, p=0.01). Patients with many episodes (>147) reported higher symptom severity (p=0.001). No differences in symptom severity nor in EQ-5D-5L scores according to AF burden or duration were observed. Conclusion In patients with early paroxysmal AF, higher AF burden and longer episode duration were associated with increased rates of healthcare utilisation but not with symptoms and quality of life. Patients with a higher number of episodes experienced more severe symptoms. Trial registration number NCT02726698.