Debora Cipriani

Debora Cipriani

Auto-generated profile, based on publicly available information

Debora Cipriani

Department of Neurosurgery, Kantonsspital Aarau, 5001 Aarau, Switzerland

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2025 in Brain Hemorrhages
Verified
Journal Article
Open access
SBStefanie Bauer
Stefanie Bauer
JHJoshua Haegler
Joshua Haegler
DCDebora Cipriani
Debora Cipriani
MBMarkus Bruder
Markus Bruder
Julien Natsumi JostJulien Natsumi Jost
Julien Natsumi Jost
LALukas Andereggen
Lukas Andereggen

25 May 2026 in Spine Open
Verified
Journal Article
Open access
Julien Natsumi JostJulien Natsumi Jost
Julien Natsumi Jost
KCKristina Catalano
Kristina Catalano
JLJaqueline Lattmann
Jaqueline Lattmann
TRThomas Rhomberg
Thomas Rhomberg
DCDebora Cipriani
Debora Cipriani
MBMarkus Bruder
Markus Bruder
Study Design: Retrospective single-center cohort study. Objective: To evaluate screw accuracy, axial trajectory characteristics relative to the anatomic pedicle axis (APA), and perioperative safety of robotic-assisted (RA) pedicle screw placement, and to determine whether percutaneous instrumentation (PI) enables reproducible medial trajectory modulation without increasing cortical breach rates. Summary of Background Data: RA pedicle screw placement achieves high categorical accuracy. However, most studies focus on breach rates and do not quantify systematic variation in axial screw angulation relative to the APA. Whether robotic workflows enable controlled trajectory modulation beyond simple intrapedicular containment remains unclear. Methods: A consecutive cohort of 146 adult patients undergoing RA pedicle screw placement using the CIRQ robotic arm (1006 screws) was analyzed. Accuracy was graded using the Gertzbein-Robbins classification (GR). Axial angulation and deviation from the APA were measured on postoperative computed tomography. Screw-level outcomes were assessed using multivariable mixed-effects regression accounting for case-level clustering. Sensitivity analyses addressed chronological case era and selection bias using inverse probability weighting. Results: Clinically acceptable placement (GR A/B) was achieved in 97.9% of screws; major malposition (GR D/E) occurred in 0.4%. Cervical location (OR: 7.10, P <0.001) and open instrumentation (OI) (OR: 8.50, P <0.001) were independently associated with increased odds of cortical breach. Imaging modality was not independently associated with accuracy. PI demonstrated significantly greater medial convergence relative to the APA (interaction P <0.001) without increased breach risk. Three screws (0.3%) required revision. No neurological deficits attributable to screw malposition were observed (mean follow-up 5.9 mo). Conclusions: RA pedicle screw placement using CIRQ achieved high accuracy and consistent safety independent of imaging modality and surgeon experience level. PI was associated with reproducible medial trajectory modulation without increased cortical breach. These findings suggest that RA permits controlled intrapedicular trajectory modulation within safe anatomic boundaries.

31 August 2026 in Brain Sciences
Verified
Journal Article
Open access
PDF file
JHJoshua Haegler
Joshua Haegler
JAJavier Añon
Javier Añon
GMGwendoline Boillat MD
Gwendoline Boillat MD
SBStefanie Bauer
Stefanie Bauer
DRDebora Roethlisberger
Debora Roethlisberger
LALukas Andereggen
Lukas Andereggen
Background: Mixed-reality head-mounted display (MR-HMD) visualization and 3D-printed models may improve three-dimensional visualization in neurosurgical planning. Detailed, reproducible descriptions of the workflows, technical requirements, and practical limitations of these techniques in aneurysm clip ligation planning remain limited. Methods: Between February 2020 and June 2021, patient-specific MR-HMD visualizations and 3D-printed models were generated for 29 patients undergoing elective surgical clip ligation of intracranial aneurysms. CT and 3D rotational angiography were fused to create patient-specific holograms for MR-HMD visualization and 3D-printed models. All cases underwent standardized modality-specific processing. Preparation and manufacturing times as well as recorded workflow-related usability observations, technical advantages, and limitations were assessed. Results: The mean total preparation time (mean ± standard deviation, SD) was 40.6 ± 10.3 min for MR-HMD visualization and 108.8 ± 17.8 min for 3D-printed models, excluding printing, washing, and curing time. The average printing time for 3D-printed models was 894.9 ± 41.6 min. MR-HMD setup in the operating room averaged 7.0 ± 2.8 min. Identified limitations included manual hologram registration and repositioning after table or patient position changes, as well as the inability to track instruments or interact with the hologram. Conclusions: Both modalities could be integrated into a standardized patient-specific workflow and serve complementary functions. MR-HMD visualization supported flexible short-term visualization, whereas 3D-printed models provided a physical model for clip planning and patient education at the cost of longer preparation and production. These findings support a combined workflow in which modality selection is guided by clinical tasks and time constraints.