Chongxiao Zhao

Chongxiao Zhao

Auto-generated profile, based on publicly available information

Chongxiao Zhao

Jilin Provincial Key Laboratory of High-Power Laser Technology and Application, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences 1 , Changchun 130033

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Acta Physica Sinica
Verified
Journal Article
Open access
PDF file
CZChong-Xiao Zhao
Chong-Xiao Zhao
YQYijie Qi
Yijie Qi
HYHui-Jie Yan
Hui-Jie Yan
TWTingting WANG
Tingting WANG
CRChun-Sheng Ren
Chun-Sheng Ren
Coaxial gun can produce high-speed and high-density plasma jet and has some potential applications in many research areas such as space thruster, space debris impact simulation, nuclear fusion, and material processing. The coaxial gun is usually composed of a pair of coaxial cylindrical and hollow electrodes. The pulsed discharge of coaxial gun has two discharge modes, i.e., deflagration mode and pre-fill mode. Compared with the pre-fill mode, deflagration discharge mode can induce a plasma jet with few impurities, high collimation, and fast speed. In this paper, the effect of gas injection mass and discharge voltage on the discharge characteristic of deflagration mode are studied with electrical and optical diagnosis including the emission spectrum, plasma velocity and discharge current measurements. The experimental results show that when the gas injection mass is relatively low, such as 1.4 mg, many plasma clusters eject from the muzzle. As the gas flowing into the coaxial gun bottom increases, the plasma density increases and the jet velocity decreases. Eventually, when the gas injection mass increases to 2.6 mg, one cluster of plasma is found and ejects from the muzzle of the gun. In the discharge process, as a small quantity of gas flows into the bottom of the coaxial gun through the electromagnetic valve continuously, new current paths will be generated at the bottom of the coaxial gun and move forward. This results in the observation of multiple plasma jet at the exit of the coaxial gun. It is noted that the plasma densities are different for different gas mass flowing into coaxial gun bottom, but the currents have little effect in the first discharge half cycle due to the small plasma inductance in discharge circuit. Meanwhile, the plasma characteristics under different voltages with the fixed gas mass of 2.6 mg flowing into the coaxial gun bottom are experimentally measured. The results show that the plasma density and speed increase with voltage increasing, which is attributed to the stronger discharge current and larger self-induced Lorentz force. More neutral particles can be ionized into plasma with discharge voltage increasing, and the transport speed becomes faster under the enhanced force. In addition, the multiple ionization phenomena are observed again when the discharge voltage increases from 5 kV to 8 kV. This study provides an insight into how to better apply the coaxial gun discharge plasma to practical engineering field. The article further verifies the phenomenon of multiple discharges at the bottom of the coaxial gun by changing the charging capacitance and analyzing the magnetic probe signals.

8 December 2022 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
CZChongxiao Zhao
Chongxiao Zhao
YCYiYi Chen
YiYi Chen
JSJian Song
Jian Song
XMXianxiu Mei
Xianxiu Mei
KPKun Qi Pan
Kun Qi Pan
DWDezhen Wang
Dezhen Wang
Plasma wall interaction inevitably occurs during the operation of tokamaks. The coaxial gun device has low operation cost and the parameters of plasma produced by the gun are close to those of type I edge localized mode (ELM); therefore, the coaxial gun is suitable in simulation experiments as a heat flux source of transient events such as type I ELM under the condition of H-mode in the International Thermonuclear Experimental Reactor. In this paper, the plasma generated by the discharge of a tapered coaxial accelerator thermal shock on a tungsten target is used to simulate the damage effect of the divertor. The plasma parameters are measured in the experiment. The velocity of the plasma is 41.7 km s−1, and the kinetic energy of a single hydrogen ion is 9.2 eV. The energy density at the center of the plasma can reach 1.5 MJ m−2, and the density can reach about 2.78 × 1015 cm−3. The reflection of plasma in the process of exposure at different angles is observed. It is observed that droplets of millimeter size splash from the target. Traces of liquid flow are observed on the surface of the target, which shows that there is a melting process on the surface of the target. The mass loss of the target is of the order of milligrams after 20 pulses. The ablation and residual stress of the target surface both decrease with a decrease in the angle. This is because the accumulated energy per unit area of the target surface decreases with a decrease in the angle. The results of the simulation experiment help us to understand the working state around the divertor target in tokamak devices.

1 September 2026 in Physics of Plasmas
Verified
Journal Article
Closed access
YCyiyi chen
yiyi chen
CZChongxiao Zhao
Chongxiao Zhao
QPQikun Pan
Qikun Pan
RZRanran Zhang
Ranran Zhang
YZYiping Zhou
Yiping Zhou
FCFei Chen
Fei Chen
A laser-produced plasma extreme ultraviolet light source is currently the only light source available for advancing the lithographic feature size into the 7 nm and beyond node. To further improve the extreme ultraviolet conversion efficiency (EUV-CE), in-depth research into the radiation mechanisms of plasma is essential. This paper presents a comparative analysis between the collinear and non-collinear dual-pulse laser irradiation tin (Sn) target schemes, revealing that the non-collinear scheme can effectively enhance the energy deposition of the main-pulse CO2 laser, reduce energy loss due to Sn plasma expansion, and increase both the radiation energy and radiation range of Sn plasma. Simulation results indicate that the maximum EUV-CE reaches 5.98% when the dual-pulse laser incident angle θ is set to 20°, representing an improvement of approximately 22.8% compared to the collinear scheme.