This paper presents the approach of an e-health system for cardiac telemonitoring which uses the development board LinkIt ONE as a monitoring system. Such board was adapted to measure the cardiac pulse, analyze it and determine whether a person is having a cardiac arrhythmia or not. When an arrhythmia appears, the prototype activates an alarm in order to report the patient's condition and its location to a caregiver or a close healthcare center. The data of the cardiac pulse is originated in an e-health sensor platform connected to an Arduino. Location data comes from a GPS module in the aforementioned board which is connected by WiFi with the virtual platform UBIDOTS. It provides visual information about the variables measured, the patient's location and the alarms; keeping the patient's caregiver or the healthcare center constantly informed.
1 December 2009 in Ingeniare. Revista chilena de ingeniería
This paper presents the conceptual design of an exoskeleton for gait rehabilitation of children. This system has electronics, mechanicals and software sections, which are implemented and tested using a mannequin of a child. The prototype uses servomotors to move robotic joints that are attached to simulated patient's legs. The design has 4 DOF (degrees of freedom) two for hip joints and other two for knee joints, in the sagittal plane. A microcontroller measures sensor signals, controls motors and exchanges data with a computer. The user interacts with a graphical interface to configure, control and monitor the exoskeleton activities. The laboratory tests show soften movements in joint angle tracking.
This article shows a simple methodology to implement an operational space control on a 6-DOF arm robot. First, the model is linearized and decoupled by feedback, next a computed torque control scheme in the operational space is implemented with a Jacobian matrix calculus running within small sampling period, is exhibited. Major simulation results performed using numerical values of an industrial PUMA robot prove the effectiveness of the proposed approach. The performance of the operational space control and the widely used computed torque control in the joint space is compared. The simulated results are presented to illustrate the behavior of the control schemes with tracking performance and robustness with respect to external disturbances and errors in the dynamic model.
This article presents the development and testing of a tactile interface prototype, HaptTech, that applies vibrotactile stimulation patterns to the fingertip, as well as an analysis of its performance when coupled to the commercial kinesthetic interface Novint Falcon. Its applicability in digital entertainment expects to improve the level of immersion into virtual reality scenarios. In the first experiment, a group of 75 subjects compared three different vibration stimuli that emulated different textures. They evaluated the stimuli on a 1 to 10 scale, where 1 means ‘non-perceivable differences’ and 10 means ‘entirely differentiable’. The obtained mean values were 9 (textures 1 and 3), 8,29 (textures 1 and 2), and 7,43 (textures 2 and 3), indicating HaptTech’s capability to reproduce differentiable stimuli. In the second experiment, 31 subjects evaluated the coupling between HaptTech and Novint Falcon. They perceived differences when the HaptTech system was activated in the context of a comparison between kinesthetic and vibrotactile plus kinesthetic stimuli. In the third experiment, the subjects evaluated the similarity between the perceived stimuli on the hand and a visualized texture pattern in a virtual environment. The resulting median values were 8, 8, and 9 for textures 1, 2, and 3, respectively, which demonstrate that the subjects perceived a high correspondence for each one.
This paper presents the implementation process of an electronic wireless system. It allows making exercises for hand rehabilitation. The patient can control movements of a mobile robot; it has to use movements of its hand and the electronic glove. The robot is controlled by an accelerometer that is located in the glove; an electronic prototyping platform obtains motion signals from the sensor and processes it.