Bum-Soon Lim

Bum-Soon Lim

Auto-generated profile, based on publicly available information

Bum-Soon Lim

Department of Dental Biomaterials Science, Dental Research Institute, School of Dentistry, Seoul National University, 101 Daehak-ro, Jongno-gu, Seoul 03080, Republic of Korea

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
PDF file
HLHyo-Jung Lee
Hyo-Jung Lee
JLJaden Lee
Jaden Lee
JLJung-Tae Lee
Jung-Tae Lee
JHJi-Soo Hong
Ji-Soo Hong
BLBum-Soon Lim
Bum-Soon Lim
Tae-Il KimTae-Il Kim
Tae-Il Kim
Lee HJ, et al. J Periodontal Implant Sci. 2015 Jun;45(3):120-126. https://doi.org/10.5051/jpis.2015.45.3.120

30 September 2019 in Korean Journal of Dental Materials
Verified
Journal Article
Closed access
SPSeo-Jin Park
Seo-Jin Park
HLHan-Ah Lee
Han-Ah Lee
SLSang-Hyeok Lee
Sang-Hyeok Lee
SSSoohwang Seok
Soohwang Seok
BLBum-Soon Lim
Bum-Soon Lim
KKKwang-Mahn Kim
Kwang-Mahn Kim
기존에 사용 중인 치관용 레진은 ISO 10477에 따른 물성 평가와 ISO 10993에 따른 생체적합성 평가를 실시하여 적합한 제품만 임상에 사용하고 있는데, 치관의 제작 방식이 다른 3D 프린팅 임시치관용 레진을 위한 국제규격은 아직 제시되지 않고 있다. 또한, 최근 다양한 3D 프린팅 임시치관용 레진이 국내에서 제조되거나 국외에서 수입되어 치과 임상에서 적용되고 있는데, 그 제품들을 평가한 연구는 매우 적은 상황이다. 본 논문에서는 식품의약품안전처 허가를 이미 받았거나 또는 국내 제조업체에서 개발 중인 3D 프린팅 임시치관용 레진 제품들의 물성을 국제규격인 ISO 10477:2018에 따라 평가하여 비교하고자 하였다. 3D 프린팅 임시치관용 레진 8종을 대상으로 ISO 10477에 따라 시편을 제작하여 수분 흡수도와 용해도, 색 안정성 및 굴곡강도 등을 평가하여 구성 성분이 주는 영향을 분석하였다. 각 3D 프린팅 임시치관용 레진 제조사들은 제조사에서 추천한 3D 프린터를 사용해야 한다고 하지만, 각 레진에 맞는 출력조건으로 3D 프린팅한 다음 충분히 후경화 처리하여 적절한 시편을 제작하였다. 수분 흡수도의 경우 실험군-B에서만 ISO 10477 요구조건(< 40 μg/ mm³)을 만족시키지 못하였고, 수분 용해도의 경우는 실험군-C, E 및 F에서 기준값(7.5μg/mm³) 이상의 용해도가 관찰되었다. 색 안정성의 경우에서는 실험군-A, E, F, G 및 H 등 5종의 레진에서 색 차이가 감지되었다. 굴곡강도의 경우에는 실험군-D와 E에서 적층방향에 따라 ISO 10477 요구조건(> 60 MPa)을 만족시키지 못한 시편이 관찰되었다. 굴곡강도의 경우 레진의 성분 등에 크게 영향을 받는 것으로 보여 임상에 적용할 제품 선택 시 구성 성분을 충분히 검토할 필요가 있을 것으로 보이며, 수분 흡수도와 용해도 및 색 안정성 등의 경우는 다른 요인도 있겠지만 아마 불충분한 중합도에 의한 것으로도 추정할 수 있다. 따라서 제조사에서 추천한 3D 프린터로 출력한 시편의 물성과 본 연구에서 출력한 시편의 물성을 비교하는 추가 연구가 필요할 것으로 보인다.

14 July 2014 in European Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
YSYu-Jin Seo
Yu-Jin Seo
BLBum-Soon Lim
Bum-Soon Lim
YPYoung Guk Park
Young Guk Park
IYIl-Hyung Yang
Il-Hyung Yang
SASug-Joon Ahn
Sug-Joon Ahn
SBSeung-Hak Baek
Seung-Hak Baek
To evaluate the effects of tooth displacement and vibration on frictional force and stick-slip phenomenon (SSP) when conventional brackets were used with a levelling/alignment wire. The samples consisted of six groups ( n = 10 per group) with combinations of tooth displacement (2mm lingual displacement [LD], 2mm gingival displacement [GD], and no displacement [control]) and vibration conditions (absence and presence at 30 Hz and 0.25 N). A stereolithographically made typodont system was used with conventional brackets and elastomeric ligatures. After application of artificial saliva, static/kinetic frictional forces (SFF/KFF) and frequency/amplitude of SSP were measured while drawing a 0.018-inch copper nickel-titanium (Cu-NiTi) archwire at a speed of 0.5mm/min for 5 minutes at 36.5 degree celsius. Two-way analysis of variance and independent t -test were performed. Tooth displacement increased SFF and KFF (control < LD < GD, all P < 0.001) and reduced SSP frequency (control > [LD, GD], P < 0.01). Vibration reduced SFF, KFF, and SSP amplitude in the control group ( P < 0.05, P < 0.05, and P < 0.001, respectively), but not in the LD and GD groups. SSP frequency was increased by vibration in the control, LD, and GD groups (all P < 0.001), and it was lower in the LD and GD groups than in the control group ( P < 0.01). When conventional brackets and a 0.018-inch Cu-NiTi archwire were used in the tooth displacement conditions (LD and GD), vibration did not significantly reduce SFF, KFF, or SSP amplitude.

31 March 2017 in Korean Journal of Dental Materials
Verified
Journal Article
Closed access
YKYoung-Dae Kwon
Young-Dae Kwon
SSSoohwang Seok
Soohwang Seok
SLSang-Hyeok Lee
Sang-Hyeok Lee
BLBum-Soon Lim
Bum-Soon Lim
The aim of this study was to compare the physical properties of the paste type MTAs with the powder-liquid mix type MTAs. The MTAs evaluated were 4 kinds of powder-liquid mix type and 2 kinds of paste

30 September 2017 in Korean Journal of Dental Materials
Verified
Journal Article
Closed access
YKYoung-Dae Kwon
Young-Dae Kwon
SSSoohwang Seok
Soohwang Seok
SLSang-Hyeok Lee
Sang-Hyeok Lee
BLBum-Soon Lim
Bum-Soon Lim
The aim of this study was to evaluate the implantation of powder-liquid mix type MTA, paste type MTA, and resin-based endodontic sealer (AH Plus) in tibia of rabbits for 12 weeks. Intraosseous implantation was tested according to ISO 10993-6:2016. After anesthesia, the cortical bone of tibia was exposed, then three or two holes were formed (2 mm in diameter × 6 mm in depth) in each side. The mixed materials according to manufacturer’s instruction were placed into the cylindrical holes. After implantation, all animals received visual inspection at least once a week and inflammation, complication, and other specific figures were recorded. All animals were euthanized 12 weeks after implantation, and the specimens received visual and histologic evaluation, then following results were obtained. New bone formation were most-abundant and uniformly in the experimental group of implantation of paste type MTA, and were observed to some extent in the experimental group of implantation of powder-liquid mix type MTA and microvascular invasion around MTA was examined. As the control groups of implantation of epoxy resin based endodontic sealer, severe lymphocytes and neutrophils were observed. Histologic evaluation revealed that both paste type MTA and powder-liquid mix type MTA were non-irritant compared with AH Plus that had no potential risk biologically, and were seemed to meet the criteria of implantation test. As the paste type MTA has similar physical and biological properties with better handling behavior, so powder-liquid mix type MTA can be substituted by the paste type MTA.

6 February 2007 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
DLDong Hee Lee
Dong Hee Lee
BLBum‐Soon Lim
Bum‐Soon Lim
YLYong‐Keun Lee
Yong‐Keun Lee
NKNa Ryoung Kim
Na Ryoung Kim
HYHyeong-Cheol Yang
Hyeong-Cheol Yang