1 June 2022 in The Astrophysical Journal
Very Long Baseline Interferometry (VLBI) astrometry is a well established technique for achieving ±10 μas parallax accuracies at frequencies well above 10 GHz. At lower frequencies, uncompensated interferometer delays associated with the ionosphere play the dominant role in limiting the astrometric accuracy. Multiview is a novel VLBI calibration method, which uses observations of multiple quasars to accurately model and remove time-variable, directional-dependent changes to the interferometer delay. Here we extend the Multiview technique by phase-referencing data to the target source (“inverse Multiview”) and test its performance. Multiple observations with a four-antenna VLBI array operating at 8.3 GHz show single-epoch astrometric accuracies near 20 μas for target–reference quasar separations up to about 7°. This represents an improvement in astrometric accuracy by up to an order of magnitude compared to standard phase-referencing.
19 March 2014 in Journal of Geodesy
13 May 2015 in Journal of Geodesy
24 January 2023 in The Astronomical Journal
Radio-loud quasars at high redshift (z ≥ 4) are rare objects in the universe and rarely observed with Very Long Baseline Interferometry (VLBI). But some of them have flux density sufficiently high for monitoring of their apparent position. The instability of the astrometric positions could be linked to the astrophysical process in the jetted active galactic nuclei in the early universe. Regular observations of the high-redshift quasars are used for estimating their apparent proper motion over several years. We have undertaken regular VLBI observations of several high-redshift quasars at 2.3 GHz (S band) and 8.4 GHz (X band) with a network of five radio telescopes: 40 m Yebes (Spain), 25 m Sheshan (China), and three 32 m telescopes of the Quasar VLBI Network (Russia)—Svetloe, Zelenchukskaya, and Badary. Additional facilities joined this network occasionally. The sources have also been observed in three sessions with the European VLBI Network in 2018–2019 and one Long Baseline Array experiment in 2018. In addition, several experiments conducted with the Very Long Baseline Array in 2017–2018 were used to improve the time sampling and the statistics. Based on these 37 astrometric VLBI experiments between 2017 and 2021, we estimated the apparent proper motions of four quasars: 0901+697, 1428+422, 1508+572, and 2101+600.
28 July 2022 in Earth, Planets and Space
The deviation of Universal Time from atomic time, expressed as UT1−UTC, reflects the irregularities of the Earth rotation speed and is key to precise geodetic applications which depend on the transformation between celestial and terrestrial reference frames. A rapidly varying quantity such as UT1−UTC demands observation scenarios enabling fast delivery of good results. These criteria are currently met only by the Very Long Baseline Interferometry (VLBI) Intensive sessions. Due to stringent requirements of a fast UT1−UTC turnaround, the observations are limited to a few baselines and a duration of one hour. Hence, the estimation of UT1−UTC from Intensives is liable to constraints and prone to errors introduced by inaccurate a priori information. One aspect in this context is that the regularly operated Intensive VLBI sessions organised by the International VLBI Service for Geodesy and Astrometry solely use stations in the northern hemisphere. Any potential systematic errors due to this northern hemisphere dominated geometry are so far unknown. Besides the general need for stimulating global geodetic measurements with southern observatories, this served as a powerful motivation to launch the SI (Southern Intensive) program in 2020. The SI sessions are observed using three VLBI antennas in the southern hemisphere: Ht (South Africa), Hb (Tasmania) and Yg (Western Australia). On the basis of UT1−UTC results from 53 sessions observed throughout 2020 and 2021, we demonstrate the competitiveness of the SI with routinely operated Intensive sessions in terms of operations and UT1−UTC accuracy. The UT1−UTC values of the SI reach an average agreement of 32 µs in terms of weighted standard deviation when compared with the conventional Intensives results of five independent analysis centers and of 27 µs compared with the 14C04 series. The mean scatter of all solutions of the considered northern hemisphere Intensives with respect to C04 is at a comparable level of 29 µs. The quality of the results is only slightly degraded if just the baseline HtHb is evaluated. In combination with the e-transfer capabilities from Ht to Hb, this facilitates continuation of the SI by ensuring rapid service UT1−UTC provision. Graphical Abstract