Grid-forming (GFM) inverters are increasingly recognized as a solution to facilitate massive grid integration of inverter-based resources and enable 100% power-electronics-based power systems. However, the overcurrent characteristics of GFM inverters exhibit major differences from those of conventional synchronous machines. Accordingly, an in-depth characterization of GFM current-limiting strategies is needed to ascertain their performance during off-nominal conditions. Although GFM current-limiting controls are primarily necessary to protect the inverter power stage, they determine the inverter behavior during and after an off-nominal system disturbance. As a result, they can profoundly impact device-level stability, transient system stability, power system protection, and fault recovery. This article offers a comprehensive review of state-of-the-art current-limiting techniques for GFM inverters and outlines open challenges where innovative solutions are needed. One key contribution of this article is the use of graphical methods that allow for intuitive understanding and visually aided comparisons of current-limiting methods. With this approach, we evaluate various performance criteria for different limiting methods, such as fault current contribution, voltage support, stability, and post-fault recovery. We also discuss the latest standards and trends as they require inverter dynamics under off-nominal conditions and outline pathways for future developments.
30 March 2022 in IEEE Transactions on Power Electronics
Grid-forming (GFM) inverters are dc–ac converters that regulate their ac terminal voltage and frequency in response to real-time measurements. Recent developments on GFM controls have focused on a particular dispatchable virtual oscillator control whose implementation features a nonlinear Andronov–Hopf oscillator at its core. In this article, we systematically model and study this controller, its synchronization dynamics, as well as its stability. We show that system voltages and frequency are regulated in a decentralized and autonomous manner while exhibiting nonlinear droop-like behavior. Small-signal models are formulated for an individual inverter connected to an infinite voltage bus in addition to systems of interconnected GFM inverters. These models allow us to characterize dynamical stability and synchronization. Robustness is shown after sweeping key system parameters under the aforementioned models that capture system performance. Numerical simulations and experimental results validate the analytical developments.
28 June 2016 in IEEE Transactions on Power Electronics
This letter investigates the resonance characteristics and stability problem caused by the interactions of multiparallel LCL-filtered inverters. Compared to single grid-connected inverter, the multiinverter system presents a more challenging resonance issue, where the inverter interactions may excite multiple resonances at various frequencies. This letter proposes a modeling and analysis method based on the current separation scheme. It reveals that an interactive resonant current that circulates between the paralleled three-phase inverters may arise, depending on the current distribution and the system resonance characteristics. This is different from the common resonant current injected into the grid and has yet been discussed before. The analysis with the root loci in the discrete z-domain are carried out with two stability constraints identified, which correspond to the conditions of triggering the interactive resonant current and common resonant current, respectively. Simulations and experimental results verify the theoretical analysis.
5 April 2017 in IEEE Transactions on Power Electronics
A main design constraint of the digitally controlled power electronics converters is the time delay of control systems, which may lead to the reduced control loop bandwidth and even unstable dynamics. Numerous time-delay compensation methods have been developed, of which the model-free schemes are independent to model accuracy whereas the model-based alternatives are sensitive to system modeling. This paper first presents a graphical illustration of four model-free delay compensation techniques, where their principles and performances are intuitively elaborated and compared by means of the impulse area equivalence method. An improved time-delay compensation approach is then proposed based on additional area insertion, which provides a wider frequency of phase compensation. Finally, the dynamic response of an LCL-filtered grid-connected inverter was tested with the studied delay compensation methods. Simulations and experimental test results validate the effectiveness of the graphical comparisons and the proposed approach.
18 December 2017 in IEEE Transactions on Power Electronics
This paper comprehensively analyzes the stability of a grid-interfacing inverter with LCL filter in the discrete domain, where the LCL filter, along with the controller, are modeled in a polar coordinate. System open-loop and closed-loop poles are analytically studied and expressed in the z-domain. Through the poles movement and distribution analysis, the relationship between system stability and the ratio of resonance frequency over sampling frequency is mathematically revealed and calculated as well as the system control gain limit. Moreover, this paper demonstrates that grid-voltage feedforward regulator would significantly alter the inverter stability in a weak power system. By means of Jury stability criterion, the stability status under different filter resonance frequency is given. The selection of resonance frequency and filter parameters makes a considerable difference on system behavior. Finally, to improve the robustness against grid inductance variation, a conservative design recommendation of filter parameters and control gain is given. Through the tests on a laboratory-scale prototype, the theoretical analysis is validated by experimental results.
25 March 2022 in IEEE Transactions on Power Electronics
Virtual oscillator control (VOC) is a time-domain strategy that leverages the dynamics of nonlinear oscillator circuits for synchronizing and regulating grid-forming inverters. In this article, we examine a class of second-order circuits composed of a harmonic oscillator and nonlinear state-dependent damping that has found extensive interest in the context of VOC. We center our analysis on the Van der Pol, Dead-zone, and Andronov-Hopf oscillators; these are characterized by several distinguishing attributes but they all share the common structure noted above. Analytical methods based on averaging and perturbation theory are outlined to derive several performance metrics related to harmonic and dynamic properties of these oscillators under a unified framework. Our results reveal that the Andronov-Hopf oscillator is well suited for grid-forming inverter applications since it can yield harmonics-free waveforms without compromising dynamic performance. Analytical results are validated with numerical simulations and experiments, and a multiinverter hardware setup is used to illustrate a practical use case.