Metrology in Chemistry Research Group, Research Centre for Metrology-Indonesian Institute of Sciences (Pusat Penelitian Metrologi – LIPI), Kawasan PUSPIPTEK, Building 456, Kelurahan Setu, 15314, Tangerang Selatan, Banten, INDONESIA
Auto-generated profile, based on publicly available information
Harry Budiman
Metrology in Chemistry Research Group, Research Centre for Metrology-Indonesian Institute of Sciences (Pusat Penelitian Metrologi – LIPI), Kawasan PUSPIPTEK, Building 456, Kelurahan Setu, 15314, Tangerang Selatan, Banten, INDONESIA
Nanostructured pure-TiO2and Cu3%-TiO2were successfully synthesized via co-precipitation method. The X-ray diffraction (XRD) result proves that the synthesized sample were predominantly in anatase phase with size in the range of 8∼16 nm, which are in good agreement with the transmission electron microscopy data. Owing to doping of copper, not only did the thermal stability of the TiO2decrease, but also a significant decrease in its particle size and a shift of the adsorption edge to a higher wavelength region appear. The activity of both pure-TiO2and Cu3%-doped TiO2was tested to study their ability to decolorize congo red (CR) dye in aqueous solution. We observed that the CR dye was decolorized faster by Cu3%-TiO2than pure-TiO2. Results of this study demonstrate a potential application of the synthesized sample for decolorizing dye pollutants from aqueous waste.
Modified silica gel was prepared to remove the heavy metal of chromium(III) from water sample. Silica gel was used as supporting material and the 2‐mercaptoimidazole was immobilized onto surface silica so that the silica would have selective properties to adsorb the heavy metal chromium(III) through the formation of coordination compound between the 2‐mercaptoimidazole and chromium(III). The characterization of modified silica gel was carried out by analyzing the Fourier Transform Infrared Spectrum of this material in order to ensure the immobilization of 2‐mercaptoimidazole onto the surface. The effect of pH solution, initial concentration of chromium(III), and interaction time were investigated in batch mode to find the adsorption properties of chromium(III) onto modified silica. The condition optimum of these parameters was applied to determine the removal percentage of chromium(III) in water sample using the modified silica gel
Investigation on precision and accuracy of gas chromatography equipped with thermal conductivity detector (GC-TCD) method for the measurement of CO2, C3H8, and CO as pollutant models at different flow rate of helium (He) carrier gas ranging from 17.50 to 36.25 ml/min were conducted. It was found that percentage of relative standard deviation (%RSD) values for both precision an accuracy show an overall gradual decrease as the carrier gas flow rates increased up to 25 ml/min. After that, the %RSD was found to increase with a further increase in the flow rate. These findings indicate that the flow rate of 25 ml/min was found to be the most precise and accurate level among all flow rates tested under experimental conditions of this study. While the %RSD values obtained at all flow rate are given in details. Consequently, our results suggest that the flow rate of carrier gas was a determining parameter for varying the precision and accuracy of the GC-TCD method. Owing to the fact that carrier gas act as a transporter of components of the mixture in the form of vapor or gas through the column, setting of the flow rate of carrier gas should in proper level achieve a precision and accuracy of the GC-TCD method.
The adsorption capacity of AO-10 from aqueous solution onto CeO2-NPs was investigated under various reaction parameters. Batch mode experiments were conducted to assess the potential of the CeO2-NPs as adsorbent for the removal of AO-10 dye from aqueous solution. Equilibrium isotherm studies were carried out under an optimum reaction condition (i.e., AO-10 dye concentration = 15 mg/L, CeO2-NPS dosage = 2 g/L, pH of dye solution = 2) obtained from this study. The equilibrium data obtained were fitted to Langmuir, Freundlich, and Redlich-Peterson isotherm models. The results shows that, the linear transform model provided the highest regression coefficient (R2 = 0.991) with the Langmuir model. The maximum monolayer adsorption capacity was found to be 33.33 mg/g at 30 °C, which is higher than some data from published literature.
26 February 2019 in Journal of Physics: Conference Series
The comparison of two pre-treatment methods, such as mechanical polishing and chemical polishing, prior to anodization of titanium surface in the ethylene glycol based electrolyte containing H 2O2, were carried out to investigate their effects on photoelectrochemical property of produced highly ordered TiO2 nanotube arrays (HOTNAs). The Tichemical polishing was conducted in electrolyte containing H2O2 (0.6% H2O2/1.4% H2O). The prepared HOTNAs were characterized by FT-IR, UV-Vis DRS and SEM. The obtained FTIR spectrum, showed vibration band at 1100 and 425 cm-1 , give strong indication on the existent of a-Ti-O-Ti-network. While from UV-Vis DRS spectra, the band gap of the fabricated HOTNAs were found in the range of 3.10-3.22 eV, which are characteristics for anatase phase. In addition, obtained SEM image indicates the existence of quite good ordered nanotube arrays morphology. Linear sweep voltammetry (LSV) measurement showed that the steady state photocurrent density of HOTNAs fabricated by Ti-chemical polishing were greater than that of prepared by Ti-mechanical polishing. The increasing of H2O2 content in electrolyte (1.5% H 2O2/3.5% H2O) affected to the enhancement of steady state photocurrent density of HOTNAs. Thus pre-treatment of the Ti foils using chemical polish method does enhance its photoelectrochemical property.