10 January 2020 in IEEE Transactions on Magnetics
Large DC current is typically measured by an open-loop sensor without a magnetic core. The widely used configuration uses a differential magnetic sensor inserted into the bus-bar hole or a differential magnetic sensor placed on the upper and lower surfaces of the bus-bar. The use of a differential sensor has the advantage of being resistant to external magnetic fields. In this paper, a new differential ultra-small magnetic sensor with the size of 23.2 mm * 16.5 mm * 7.2 mm is designed. The sensor is based on tunneling magnetoresistance (TMR) and is placed on the upper surface edge of the bus-bar. The supply voltage is 5 V, the rated current measurement range is 150 A and the peak current measurement range is 250 A, corresponding to 2.5 2 V output at 250 A DC peak current. The relative accuracy is less than 1% at 25 C and is less than 2% over the full temperature range from -40 C to 105 C.
16 June 2021 in IEEE Transactions on Instrumentation and Measurement
Busbar current sensor without magnetic core is used more and more in compact power electronic equipment due to its small size and lightweight. The differential measurement technique is generally adopted to resist external magnetic interference. The sensitivity of busbar current sensors varies with the frequency of the sensed current due to the skin effect in the busbar. Traditional coreless busbar current sensors can accurately measure dc current, but the measurement error increases when sensing high-frequency ac current. A coreless sensor configuration based on four tunneling magnetoresistance (TMR) chips is proposed in this article with high measurement accuracy for both dc and high-frequency ac currents while eliminating the effect of magnetic stray field. An optimization method is introduced for the layout of the TMR chips around the busbar in order to obtain a current error below 1.5% up to 1 kHz. The effectiveness of the proposed sensor configuration and layout optimization method are verified by finite element simulation and prototype tests.
1 January 2021 in Journal of Sensors
In recent years, new energy vehicles, photovoltaic power stations, communication base stations, energy storage systems, and other power electronic systems have developed rapidly. The development of these systems has the trend of continuously increasing the power density per unit area, reducing the system volume, and continuously increasing using the busbars. More and more new current sensors will be used in these systems and play a key role. Traditional current sensor cannot meet the development trend of power electronic systems due to their large size and high cost. In this paper, a new small coreless tunnel junction magnetoresistance (TMR) busbar dc current sensor adopted differential scheme which improves the sensor’s anti‐interference ability that is designed. The current sensor adopts an open‐closed structure for easy nonintrusive installation. Four TMRs which adopted differential structure are placed on the edges of the busbar. The peak current measurement range is ±600 A, the rated current measurement range is ±300 A, and the supply voltage is 5 V.
28 December 2022 in IEEE Transactions on Instrumentation and Measurement
In an electrified railway system, electrical energy is provided to the train through the traction network for its normal operation. Starting from the traction substation, the traction current flows through the catenary, the train, and finally returns to the traction substation via the steel rail. Due to the absence of on-line detection technology for rail current, it has been a long time that the magnitude of the current flowing on the rail is unclear. Therefore, how to effectively detect rail current has become an industrial and academic focus recently. This paper uses a new type of tunnel magnetoresistance sensor, focusing on the rail power frequency current online detection technology based on the tunnel magnetoresistance gradient method. First, this paper analyzes the current and the magnetic field distribution characteristics near the rail, then considers the actual installation situation on the spot, and selects the appropriate sensor installation location. Finally, through simulation and actual measurement, it is verified that the scheme has a flexible structure, easy installation, strong anti-interference ability and good detection accuracy.